17 matches found

NVD
NVD
added 2019/03/25 7:29 p.m.20 views

CVE-2015-1012

Wireless keys are stored in plain text on version 5 of the Hospira LifeCare PCA Infusion System. According to Hospira, version 3 of the LifeCare PCA Infusion System is not indicated for wireless use, is not shipped with wireless capabilities, and should not be modified to be used in a wireless...

7.5CVSS7.5AI score0.00771EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2019/03/25 6:20 p.m.25 views

CVE-2015-1012

Wireless keys are stored in plain text on version 5 of the Hospira LifeCare PCA Infusion System. According to Hospira, version 3 of the LifeCare PCA Infusion System is not indicated for wireless use, is not shipped with wireless capabilities, and should not be modified to be used in a wireless...

7.5AI score0.00771EPSS
SaveExploits0References1
Prion
Prion
added 2016/01/22 11:59 a.m.17 views

Stack overflow

Stack-based buffer overflow in Hospira Communication Engine CE before 1.2 in LifeCare PCA Infusion System 5.07, Plum A+ Infusion System 13.40, and Plum A+3 Infusion System 13.40 allows remote attackers to cause a denial of service or possibly have unspecified other impact via traffic on TCP port...

7.5CVSS8.6AI score0.01112EPSS
SaveExploits0References1Affected Software2
CVE
CVE
added 2016/01/22 11:00 a.m.55 views

CVE-2015-7909

Hospira LifeCare PCA Infusion System (v5.07) and Plum A+/A+3 Infusion Systems (CE prior to v1.2) are affected by a stack-based buffer overflow in the Hospira Communication Engine (CE) exposed on TCP port 5000. The vulnerability enables a remote attacker to cause a denial of service (and potential...

7.5CVSS8AI score0.01112EPSS
SaveExploits0References1Affected Software2
BDU FSTEC
BDU FSTEC
added 2015/08/07 12:00 a.m.14 views

The vulnerability of the microprogrammed software of the LifeCare PCA Infusion System allows a perpetrator to compromise the security of the protected information.

The vulnerability of the microprogrammed medical device LifeCare PCA Infusion System is related to errors in managing registration data. Exploiting this vulnerability could allow an intruder, operating locally, to compromise the security of protected information due to the storage of closed keys...

4.6CVSS5.5AI score0.00544EPSS
SaveExploits0References3Affected Software1
NVD
NVD
added 2015/07/06 7:59 p.m.24 views

CVE-2015-3957

Hospira LifeCare PCA Infusion System before 7.0 stores private keys and certificates, which has unspecified impact and attack vectors...

4.6CVSS8.1AI score0.00544EPSS
SaveExploits0References3
NVD
NVD
added 2015/07/06 7:59 p.m.22 views

CVE-2015-1011

Hospira LifeCare PCA Infusion System before 7.0 has hardcoded credentials, which makes it easier for remote attackers to obtain access via unspecified vectors...

5CVSS7.4AI score0.02228EPSS
SaveExploits0References2
Prion
Prion
added 2015/07/06 7:59 p.m.21 views

Design/Logic Flaw

The Hospira LifeCare PCA Infusion System before 7.0 does not validate network traffic associated with sending a 1 drug library, 2 software update, or 3 configuration change, which allows remote attackers to modify settings or medication data via packets on the a TELNET, b HTTP, c HTTPS, or d UPNP...

9.3CVSS7AI score0.05064EPSS
SaveExploits0References3Affected Software1
Cvelist
Cvelist
added 2015/07/06 7:10 p.m.25 views

CVE-2015-3957

Hospira LifeCare PCA Infusion System before 7.0 stores private keys and certificates, which has unspecified impact and attack vectors...

6.6AI score0.00544EPSS
SaveExploits0References3
Cvelist
Cvelist
added 2015/07/06 7:10 p.m.27 views

CVE-2015-3958

Hospira LifeCare PCA Infusion System 5.0 and earlier, and possibly other versions, allows remote attackers to cause a denial of service forced manual reboot via a flood of TCP packets...

6.7AI score0.02612EPSS
SaveExploits0References3
Cvelist
Cvelist
added 2015/07/06 7:10 p.m.31 views

CVE-2015-1011

Hospira LifeCare PCA Infusion System before 7.0 has hardcoded credentials, which makes it easier for remote attackers to obtain access via unspecified vectors...

6.6AI score0.02228EPSS
SaveExploits0References2
CVE
CVE
added 2015/07/06 7:10 p.m.62 views

CVE-2014-5406

Hospira LifeCare PCA Infusion System prior to version 7.0 is affected by CVE-2014-5406. The device’s network-facing components (TELNET, HTTP/HTTPS, UPNP) do not validate or restrict incoming traffic, enabling an unauthenticated remote attacker to modify drug libraries, software updates, or pump c...

9.3CVSS6.6AI score0.01242EPSS
SaveExploits0References5Affected Software1
Cvelist
Cvelist
added 2015/07/06 7:10 p.m.29 views

CVE-2014-5406 Hospira LifeCare PCA Infusion System

The Hospira LifeCare PCA Infusion System before 7.0 does not validate network traffic associated with sending a 1 drug library, 2 software update, or 3 configuration change, which allows remote attackers to modify settings or medication data via packets on the a TELNET, b HTTP, c HTTPS, or d UPNP...

7.6CVSS7.4AI score0.01242EPSS
SaveExploits0References4
Cvelist
Cvelist
added 2015/07/06 7:10 p.m.28 views

CVE-2015-3955

Stack-based buffer overflow in Hospira LifeCare PCA Infusion System 5.0 and earlier, and possibly other versions, allows remote attackers to execute arbitrary code via unspecified vectors...

8.2AI score0.0675EPSS
SaveExploits0References3
Prion
Prion
added 2015/04/29 11:59 p.m.18 views

Authentication flaw

The communication module on the Hospira LifeCare PCA Infusion System before 7.0 does not require authentication for root TELNET sessions, which allows remote attackers to modify the pump configuration via unspecified commands...

10CVSS7.1AI score0.05064EPSS
SaveExploits0References8Affected Software1
Cvelist
Cvelist
added 2015/04/29 11:00 p.m.29 views

CVE-2015-3459

The communication module on the Hospira LifeCare PCA Infusion System before 7.0 does not require authentication for root TELNET sessions, which allows remote attackers to modify the pump configuration via unspecified commands...

6.7AI score0.05064EPSS
SaveExploits0References8
ICS
ICS
added 2015/02/05 7:00 a.m.34 views

Hospira LifeCare PCA Infusion System Vulnerabilities

OVERVIEW Independent researcher Billy Rios has identified an improper authorization vulnerability and an insufficient verification of data authenticity vulnerability in Hospira’s LifeCare PCA Infusion System, which NCCIC/ICS-CERT has been coordinating with Hospira since May 2014. This advisory is...

10CVSS7.9AI score0.05064EPSS
SaveExploits0References10