54 matches found
LenelS2 NetBox XSS
The vulnerability of the LenelS2 NetBox access control and event monitoring system is related to the lack of measures taken to protect the website structure. Exploiting this vulnerability could allow a malicious actor to perform cross-site scripting attacks XSS remotely...
LenelS2 NetBox Unauthorized Access
The vulnerability of the LenelS2 NetBox access control and event monitoring system is related to the lack of measures taken to protect the website structure. Exploiting this vulnerability could allow an attacker operating remotely to gain unauthorized access to protected information...
LenelS2 NetBox XSS
The vulnerability of the LenelS2 NetBox access control and event monitoring system is related to the lack of measures taken to protect the website structure. Exploiting this vulnerability could allow a malicious actor to perform cross-site scripting attacks XSS remotely...
CVE-2024-2421
LenelS2 NetBox access control and event monitoring system was discovered to contain an unauthenticated RCE in versions prior to and including 5.6.1, which allows an attacker to execute malicious commands with elevated permissions...
CVE-2024-2422
LenelS2 NetBox access control and event monitoring system was discovered to contain an authenticated RCE in versions prior to and including 5.6.1, which allows an attacker to execute malicious commands...
EUVD-2024-27371
Malicious code in bioql PyPI...
EUVD-2024-27373
Malicious code in bioql PyPI...
EUVD-2024-27372
Malicious code in bioql PyPI...
CVE-2024-2420
LenelS2 NetBox access control and event monitoring system was discovered to contain Hardcoded Credentials in versions prior to and including 5.6.1 which allows an attacker to bypass authentication requirements...
LenelS2 NetBox Authentication Bypass
The vulnerability of the LenelS2 NetBox access control and event monitoring system lies in the use of strictly encrypted login credentials. Exploiting this vulnerability could allow a malicious actor to bypass the authentication process remotely...
LenelS2 NetBox Access Control Command Execution
The vulnerability of the LenelS2 NetBox access control and event monitoring system is related to the implementation or modification of arguments. Exploiting this vulnerability allows a malicious actor to execute arbitrary commands remotely...
LenelS2 NetBox Command Injection
The vulnerability of the LenelS2 NetBox access control and event monitoring system lies in the lack of measures taken to neutralize the special elements used in the operating system’s commands. Exploiting this vulnerability allows a malicious actor to execute arbitrary commands and increase their...
CVE-2024-2422
LenelS2 NetBox access control and event monitoring system was discovered to contain an authenticated RCE in versions prior to and including 5.6.1, which allows an attacker to execute malicious commands...
CVE-2024-2420
LenelS2 NetBox access control and event monitoring system was discovered to contain Hardcoded Credentials in versions prior to and including 5.6.1 which allows an attacker to bypass authentication requirements...
CVE-2024-2421
LenelS2 NetBox access control and event monitoring system was discovered to contain an unauthenticated RCE in versions prior to and including 5.6.1, which allows an attacker to execute malicious commands with elevated permissions...
CVE-2024-2420
LenelS2 NetBox access control and event monitoring system was discovered to contain Hardcoded Credentials in versions prior to and including 5.6.1 which allows an attacker to bypass authentication requirements...
CVE-2024-2421
LenelS2 NetBox access control and event monitoring system was discovered to contain an unauthenticated RCE in versions prior to and including 5.6.1, which allows an attacker to execute malicious commands with elevated permissions...
CVE-2024-2422
LenelS2 NetBox access control and event monitoring system was discovered to contain an authenticated RCE in versions prior to and including 5.6.1, which allows an attacker to execute malicious commands...
CVE-2024-2422 LenelS2 NetBox Improper Neutralization of Argumented Delimiters
LenelS2 NetBox access control and event monitoring system was discovered to contain an authenticated RCE in versions prior to and including 5.6.1, which allows an attacker to execute malicious commands...
CVE-2024-2422 LenelS2 NetBox Improper Neutralization of Argumented Delimiters
LenelS2 NetBox access control and event monitoring system was discovered to contain an authenticated RCE in versions prior to and including 5.6.1, which allows an attacker to execute malicious commands...