5291 matches found
Schneider Electric Enerlin’X IFE and eIFE
GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install...
Schneider Electric Uni-Telway Driver (Update D)
GENERAL SECURITY RECOMMENDATIONS We strongly recommend the following industry cybersecurity best practices. https://www.se.com/us/en/download/document/7EN52-0390/ Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install...
CVE-2025-0158
IBM EntireX 11.1 could allow a local user to cause a denial of service due to an unhandled error and fault isolation...
[SECURITY] Fedora 41 Update: libkrun-1.10.1-2.fc41
Dynamic library providing Virtualization-based process isolation capabilities...
CVE-2025-0158
IBM EntireX 11.1 could allow a local user to cause a denial of service due to an unhandled error and fault isolation...
CVE-2025-0158
IBM EntireX 11.1 could allow a local user to cause a denial of service due to an unhandled error and fault isolation...
CVE-2025-0158
IBM EntireX 11.1 is affected by CVE-2025-0158, which could allow a local user to cause a denial of service due to an unhandled error and faulty isolation. The issue is documented in IBM Security Bulletin noting CWE-248 (Uncaught Exception) and a CVSS base of 5.5 (Medium) from IBM’s assessment. Pu...
CVE-2025-0158 IBM EntireX denial of service
IBM EntireX 11.1 could allow a local user to cause a denial of service due to an unhandled error and fault isolation...
PT-2025-5871 · Ibm · Ibm Entirex
Name of the Vulnerable Software and Affected Versions: IBM EntireX version 11.1 Description: The issue could allow a local user to cause a denial of service due to an unhandled error and fault isolation. Recommendations: For IBM EntireX version 11.1, at the moment, there is no information about a...
IBM EntireX 安全漏洞
IBM EntireX is a versatile middleware solution from International Business Machines IBM designed to facilitate seamless integration between core enterprise applications and modern applications. A security vulnerability exists in IBM EntireX version 11.1 that stems from the presence of unhandled...
CVE-2020-4076
In Electron before versions 7.2.4, 8.2.4, and 9.0.0-beta21, there is a context isolation bypass. Code running in the main world context in the renderer can reach into the isolated Electron context and perform privileged actions. Apps using contextIsolation are affected. This is fixed in versions...
CVE-2020-4077
In Electron before versions 7.2.4, 8.2.4, and 9.0.0-beta21, there is a context isolation bypass. Code running in the main world context in the renderer can reach into the isolated Electron context and perform privileged actions. Apps using both contextIsolation and contextBridge are affected. Thi...
CVE-2024-38868
Zohocorp ManageEngine Endpoint Central affected by Incorrect authorization vulnerability while isolating the devices.This issue affects Endpoint Central: before 11.3.2406.08 and before 11.3.2400.15...
CVE-2024-41977
A vulnerability has been identified in RUGGEDCOM RM1224 LTE4G EU 6GK6108-4AM00-2BA2 All versions V8.1, RUGGEDCOM RM1224 LTE4G NAM 6GK6108-4AM00-2DA2 All versions V8.1, SCALANCE M804PB 6GK5804-0AP00-2AA2 All versions V8.1, SCALANCE M812-1 ADSL-Router family All versions V8.1, SCALANCE M816-1...
Cross-site Scripting (XSS)
Backdrop CMS is vulnerable to Cross-site Scripting XSS. The vulnerability is due to improper content isolation due to insufficient sanitization of long text content when using the CKEditor 5 rich text editor, allowing an attacker to inject malicious HTML and JavaScript that executes when an...
Unauthorized Rule Injection
ArgoCD is vulnerable to unauthorized rule injection. The vulnerability is due to improper namespace isolation, as the openshift.io/cluster-monitoring label is automatically applied to all namespaces deploying an ArgoCD CR instance, allowing them to create unauthorized PrometheusRule objects...
Contec Health CMS8000 Patient Monitor (Update A)
RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to remotely send specially formatted UDP requests or connect to an unknown external network that would allow them to write arbitrary data, resulting in remote code execution. The device may also leak patient...
cri-o: Checkpoint restore can be triggered from different namespaces
A vulnerability was found in CRI-O, where it can be requested to take a checkpoint archive of a container and later be asked to restore it. When it does that restoration, it attempts to restore the mounts from the restore archive instead of the pod request. As a result, the validations run on the...
SUSE CVE-2024-0135
NVIDIA Container Toolkit contains an improper isolation vulnerability where a specially crafted container image could lead to modification of a host binary. A successful exploit of this vulnerability may lead to code execution, denial of service, escalation of privileges, information disclosure,...
GO-2025-3427 Malicious PrometheusRule creation to all namespaces that deploy a ArgoCD CR instance in github.com/redhat-developer/gitops-operator
Malicious PrometheusRule creation to all namespaces that deploy a ArgoCD CR instance in github.com/redhat-developer/gitops-operator...