•added 2021/03/11 12:00 a.m.•5 views

CVE-2021-22712: Improper Restriction of Operations within the Bounds of a Memory Buffer

A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System IGSS Definition Def.exe V15.0.0.21041 and prior, which could result in arbitrary read or write conditions when malicious CGF Configuration Group File file i...

9.3CVSS5.8AI score0.00933EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/03/11 12:00 a.m.•7 views

CVE-2021-22709: Improper Restriction of Operations within the Bounds of a Memory Buffer

A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System IGSS Definition Def.exe V15.0.0.21041 and prior, which could result in loss of data or remote code execution when malicious CGF Configuration Group File fil...

9.3CVSS6.2AI score0.02219EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/03/11 12:00 a.m.•6 views

CVE-2021-22710: Improper Restriction of Operations within the Bounds of a Memory Buffer

A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System IGSS Definition Def.exe V15.0.0.21041 and prior, which could cause remote code execution when malicious CGF Configuration Group File file is imported to IGS...

9.3CVSS6.3AI score0.02219EPSS
SaveExploits0References2
CNNVD
CNNVD
•added 2021/03/11 12:00 a.m.•18 views

Schneider Electric Interactive Graphical SCADA System 缓冲区错误漏洞

Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. A buffer overflow vulnerability exists in Interactive Graphical SCADA System IGSS Definition...

9.3CVSS6.2AI score0.00933EPSS
SaveExploits0References6
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2021/03/11 12:00 a.m.•6 views

CVE-2021-22711: Improper Restriction of Operations within the Bounds of a Memory Buffer

A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System IGSS Definition Def.exe V15.0.0.21041 and prior, which could result in arbitrary read or write conditions when malicious CGF Configuration Group File file i...

9.3CVSS5.9AI score0.00883EPSS
SaveExploits0References2
CNNVD
CNNVD
•added 2021/03/11 12:00 a.m.•20 views

Schneider Electric Interactive Graphical SCADA System 缓冲区错误漏洞

Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA data acquisition and monitoring system system for monitoring and controlling industrial processes from Schneider Electric, a French company. Electric Interactive Graphical SCADA System is vulnerable to a buffer overflow...

9.3CVSS6.6AI score0.02219EPSS
SaveExploits0References6
Positive Technologies
Positive Technologies
•added 2021/03/09 12:00 a.m.•3 views

PT-2021-2377

Name of the Vulnerable Software and Affected Versions Interactive Graphical SCADA System IGSS versions prior to 15.0.0.21041 Description The issue is caused by a buffer overflow in memory, allowing a remote attacker to read or write arbitrary files using a specially crafted CGF file. This is due ...

9.3CVSS0.00883EPSS
SaveExploits0References7
Positive Technologies
Positive Technologies
•added 2021/03/09 12:00 a.m.•3 views

PT-2021-2330

Name of the Vulnerable Software and Affected Versions Interactive Graphical SCADA System IGSS versions 15.0.0.21041 and prior Description A memory buffer vulnerability exists due to improper restriction of operations within the bounds of a memory buffer, which could result in arbitrary read or...

9.3CVSS0.00933EPSS
SaveExploits0References7
Positive Technologies
Positive Technologies
•added 2021/03/09 12:00 a.m.•1 views

PT-2021-2368

Name of the Vulnerable Software and Affected Versions Interactive Graphical SCADA System IGSS versions 15.0.0.21041 and prior Description A memory buffer vulnerability exists in the Interactive Graphical SCADA System IGSS Definition, which could result in loss of data or remote code execution whe...

9.3CVSS0.02219EPSS
SaveExploits0References7
Positive Technologies
Positive Technologies
•added 2021/03/09 12:00 a.m.•1 views

PT-2021-2378

Name of the Vulnerable Software and Affected Versions Interactive Graphical SCADA System IGSS versions 15.0.0.21041 and prior Description A memory buffer vulnerability exists, which could cause remote code execution when a malicious CGF Configuration Group File file is imported to IGSS Definition...

9.3CVSS0.02219EPSS
SaveExploits0References8
CNVD
CNVD
•added 2020/11/26 12:00 a.m.•18 views

Schneider Electric Interactive Graphical SCADA System Buffer Overflow Vulnerability (CNVD-2020-67319)

Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. The Interactive Graphical SCADA System suffers from a buffer overflow vulnerability that stems...

7.8CVSS8.3AI score0.01654EPSS
SaveExploits0References1
CNVD
CNVD
•added 2020/11/23 12:00 a.m.•85 views

Schneider Electric Interactive Graphical SCADA System Out-of-Bounds Write Vulnerability

Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. An out-of-bounds write vulnerability exists in Interactive Graphical SCADA System version...

7.8CVSS7.6AI score0.02477EPSS
SaveExploits0References1
CNNVD
CNNVD
•added 2020/11/17 12:00 a.m.•17 views

Schneider Electric Interactive Graphical SCADA System Buffer Error Vulnerability

The Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. The Interactive Graphical SCADA System suffers from a buffer error vulnerability that...

7.8CVSS7.8AI score0.02489EPSS
SaveExploits0References5
CNNVD
CNNVD
•added 2020/11/17 12:00 a.m.•21 views

Schneider Electric Interactive Graphical SCADA System Buffer Error Vulnerability

The Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. The Interactive Graphical SCADA System suffers from a buffer error vulnerability that stems...

7.8CVSS7.8AI score0.02477EPSS
SaveExploits0References5
CNNVD
CNNVD
•added 2020/11/17 12:00 a.m.•25 views

Schneider Electric Interactive Graphical SCADA System Buffer Error Vulnerability

The Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. The Interactive Graphical SCADA System suffers from a buffer error vulnerability that stems...

7.8CVSS7.8AI score0.02477EPSS
SaveExploits0References5
CNNVD
CNNVD
•added 2020/11/17 12:00 a.m.•28 views

Schneider Electric Interactive Graphical SCADA System Buffer Error Vulnerability

The Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. The Interactive Graphical SCADA System suffers from a buffer error vulnerability that stems...

7.8CVSS7.8AI score0.02499EPSS
SaveExploits0References5
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2019/07/15 12:00 a.m.•5 views

CVE-2019-6827: Out-of-bounds Write

A CWE-787: Out-of-bounds Write vulnerability exists in Interactive Graphical SCADA System IGSS, Version 14 and prior, which could cause a software crash when data in the mdb database is manipulated...

7.8CVSS5.8AI score0.01279EPSS
SaveExploits0References3
ICS
ICS
•added 2019/07/11 12:00 a.m.•38 views

Schneider Electric Interactive Graphical SCADA System

1. EXECUTIVE SUMMARY CVSS v3 7.0 Vendor: Schneider Electric Equipment: Interactive Graphical SCADA System IGSS Vulnerability: Out-of-Bounds Write 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to achieve arbitrary code execution or crash the software. 3...

7.8CVSS8.1AI score0.01279EPSS
SaveExploits0References5
CNVD
CNVD
•added 2017/04/11 12:00 a.m.•19 views

Schneider Electric Interactive Graphical SCADA DLL Load Remote Code Execution Vulnerability

Schneider Electric Interactive Graphical SCADA System Software is a suite of automation software for process control and supervision of SCADA systems from the French company Schneider Electric SchneiderElectric. A DLL loading remote code execution vulnerability exists in Schneider Electric...

7.8CVSS8.4AI score0.0134EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2017/04/07 12:00 a.m.•4 views

PT-2017-16848

Name of the Vulnerable Software and Affected Versions Schneider Electric Interactive Graphical SCADA System IGSS Software versions prior to 12 Description A DLL Hijacking issue allows execution of a malicious file if it is named the same as a legitimate file and placed in a location that is earli...

7.8CVSS5.9AI score0.0134EPSS
SaveExploits0References5