Lucene search
+L

66 matches found

Prion
Prion
•added 2016/11/23 11:59 a.m.•27 views

Server side request forgery (ssrf)

A vulnerability has been identified in SIMATIC CP 343-1 Advanced incl. SIPLUS NET variant All versions V3.0.53, SIMATIC CP 443-1 Advanced incl. SIPLUS NET variant All versions V3.2.17, SIMATIC S7-300 PN/DP CPU family incl. SIPLUS variants All versions, SIMATIC S7-400 PN/DP CPU family incl. SIPLUS...

6.8CVSS7AI score0.01112EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2016/11/23 12:00 a.m.•7 views

CVE-2016-8673: Cross-Site Request Forgery (CSRF)

A vulnerability has been identified in SIMATIC CP 343-1 Advanced incl. SIPLUS NET variant All versions V3.0.53, SIMATIC CP 443-1 Advanced incl. SIPLUS NET variant All versions V3.2.17, SIMATIC S7-300 PN/DP CPU family incl. SIPLUS variants All versions, SIMATIC S7-400 PN/DP CPU family incl. SIPLUS...

8.8CVSS5.7AI score0.01112EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2016/07/22 12:00 a.m.•3 views

PT-2016-6798

Name of the Vulnerable Software and Affected Versions Siemens SINEMA Remote Connect Server versions prior to 1.2 Description The issue is related to a cross-site scripting XSS vulnerability in the integrated web server. This allows remote attackers to inject arbitrary web script or HTML via a...

6.1CVSS0.0161EPSS
SaveExploits0References5
OSV
OSV
•added 2016/05/31 1:59 a.m.•6 views

CVE-2016-4784

A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...

5.3CVSS5.7AI score0.02676EPSS
SaveExploits0References6
NVD
NVD
•added 2016/05/31 1:59 a.m.•29 views

CVE-2016-4784

A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions V1.03; Firmware variant IEC 104...

5.3CVSS6AI score0.02676EPSS
SaveExploits0References6
Positive Technologies
Positive Technologies
•added 2016/05/31 12:00 a.m.•2 views

PT-2016-6138

Name of the Vulnerable Software and Affected Versions EN100 Ethernet module firmware variant PROFINET IO versions prior to V1.04.01 EN100 Ethernet module firmware variant Modbus TCP versions prior to V1.11.00 EN100 Ethernet module firmware variant DNP3 TCP versions prior to V1.03 EN100 Ethernet...

5.3CVSS0.02676EPSS
SaveExploits0References8
Positive Technologies
Positive Technologies
•added 2015/06/28 12:00 a.m.•3 views

PT-2015-6445

Name of the Vulnerable Software and Affected Versions Siemens Climatix BACnet/IP communication module versions prior to 10.34 Description A cross-site scripting XSS issue exists, allowing remote attackers to inject arbitrary web script or HTML via a crafted URL. This affects the integrated web...

4.3CVSS0.02526EPSS
SaveExploits1References5
Positive Technologies
Positive Technologies
•added 2015/02/02 12:00 a.m.•3 views

PT-2015-1271

Name of the Vulnerable Software and Affected Versions Siemens Ruggedcom WIN51xx versions prior to SS4.4.4624.35 Siemens Ruggedcom WIN52xx versions prior to SS4.4.4624.35 Siemens Ruggedcom WIN70xx versions prior to BS4.4.4621.32 Siemens Ruggedcom WIN72xx versions prior to BS4.4.4621.32 Description...

10CVSS0.03766EPSS
SaveExploits0References7
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2015/02/02 12:00 a.m.•5 views

CVE-2015-1449: Improper Restriction of Operations within the Bounds of a Memory Buffer

Buffer overflow in the integrated web server on Siemens Ruggedcom WIN51xx devices with firmware before SS4.4.4624.35, WIN52xx devices with firmware before SS4.4.4624.35, WIN70xx devices with firmware before BS4.4.4621.32, and WIN72xx devices with firmware before BS4.4.4621.32 allows remote...

10CVSS6.6AI score0.03766EPSS
SaveExploits0References2
CNVD
CNVD
•added 2015/01/22 12:00 a.m.•18 views

Siemens SIMATIC S7-1200 Open Redirect Vulnerability

The Siemens SIMATIC S7-1200 is a modular PLC controller. An open redirection vulnerability exists in integrated web server on Siemens SIMATIC S7-1200 CPU devices with firmware prior to version 4.1, which allows remote attackers to redirect a user to an arbitrary web site via an unspecified vector...

4.3CVSS6.8AI score0.01493EPSS
SaveExploits0References1
NVD
NVD
•added 2014/07/07 11:01 a.m.•31 views

CVE-2014-2967

Autodesk VRED Professional 2014 before SR1 SP8 allows remote attackers to execute arbitrary code via Python os library calls in Python API commands to the integrated web server...

10CVSS7.8AI score0.05073EPSS
SaveExploits0References1
Prion
Prion
•added 2014/07/07 11:01 a.m.•29 views

Design/Logic Flaw

Autodesk VRED Professional 2014 before SR1 SP8 allows remote attackers to execute arbitrary code via Python os library calls in Python API commands to the integrated web server...

10CVSS8.4AI score0.05073EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
•added 2014/07/07 10:00 a.m.•45 views

CVE-2014-2967

Autodesk VRED Professional 2014 before SR1 SP8 allows remote attackers to execute arbitrary code via Python os library calls in Python API commands to the integrated web server...

7.8AI score0.05073EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2014/07/07 12:00 a.m.•6 views

CVE-2014-2967: Improper Neutralization of Special Elements used in an OS Command

Autodesk VRED Professional 2014 before SR1 SP8 allows remote attackers to execute arbitrary code via Python os library calls in Python API commands to the integrated web server...

10CVSS6.5AI score0.05073EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2014/07/07 12:00 a.m.•3 views

PT-2014-4989

Name of the Vulnerable Software and Affected Versions Autodesk VRED Professional 2014 versions before SR1 SP8 Description The issue allows remote attackers to execute arbitrary code via Python os library calls in Python API commands to the integrated web server. Recommendations For Autodesk VRED...

10CVSS0.05073EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2014/04/25 12:00 a.m.•9 views

CVE-2014-2909: Improper Control of Generation of Code

CRLF injection vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices 2.x and 3.x allows remote attackers to inject arbitrary HTTP headers via unspecified vectors...

5.8CVSS7.4AI score0.02417EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2014/04/25 12:00 a.m.•10 views

CVE-2014-2908: Improper Neutralization of Input During Web Page Generation

Cross-site scripting XSS vulnerability in the integrated web server on Siemens SIMATIC S7-1200 CPU devices 2.x and 3.x allows remote attackers to inject arbitrary web script or HTML via unspecified vectors...

4.3CVSS6AI score0.20862EPSS
SaveExploits3References2
Positive Technologies
Positive Technologies
•added 2014/04/25 12:00 a.m.•3 views

PT-2014-4954

Name of the Vulnerable Software and Affected Versions Siemens SIMATIC S7-1200 CPU devices versions 2.x through 3.x Description A cross-site scripting XSS issue exists in the integrated web server, allowing remote attackers to inject arbitrary web script or HTML. This could potentially lead to...

4.3CVSS0.20862EPSS
SaveExploits3References5
Positive Technologies
Positive Technologies
•added 2014/04/24 12:00 a.m.•5 views

PT-2014-1179

Name of the Vulnerable Software and Affected Versions Siemens SIMATIC S7-1200 CPU devices versions 2.x through 3.x Description The issue concerns a CRLF injection vulnerability in the integrated web server of the affected devices. This vulnerability allows remote attackers to inject arbitrary HTT...

5.8CVSS0.02417EPSS
SaveExploits1References7
Prion
Prion
•added 2014/04/19 7:55 p.m.•31 views

Code injection

Multiple unspecified vulnerabilities in the integrated web server in Siemens SINEMA Server before 12 SP1 allow remote attackers to execute arbitrary code via HTTP traffic to port 1 4999 or 2 80...

9.3CVSS8.3AI score0.04243EPSS
SaveExploits1References2Affected Software1
Rows per page
Query Builder