611 matches found
CVE-2013-5026
An ActiveX control in lookout650.ocx, lookout660.ocx, and lookout670.ocx in National Instruments Lookout 6.5 through 6.7 allows remote attackers to execute arbitrary code by triggering the download of, and calls to, an arbitrary DLL file...
CVE-2013-5023
The vulnerability CVE-2013-5023 affects NI software (e.g., LabWindows/CVI 2012 SP1 and earlier, LabVIEW 2012 SP1 and earlier) where ActiveX controls in the HelpAsst component of NI Help Links can be triggered to display local CHM files, enabling remote denial of service. The underlying issue is e...
CVE-2013-5021
The CVE-2013-5021 issue affects multiple National Instruments CWUI ActiveX controls (CWNumEdit, CWGraph, CWBoolean, CWSlide, CWKnob) used in NI LabWindows/CVI 2012 SP1 and earlier, LabVIEW 2012 SP1 and earlier, and ABB DataManager Data Analysis. A root cause in the ExportStyle() method enables ab...
CVE-2013-5025
An ActiveX control in exlauncher.dll in the Help subsystem in National Instruments LabWindows/CVI before 2013 allows remote attackers to cause a denial of service by triggering the display of local example files...
CVE-2013-5022
The CVE-2013-5022 entry concerns an Absolute path traversal via the CWGraph3D ActiveX control (cw3dgrph.ocx) in National Instruments LabWindows/CVI 2012 SP1 and earlier, LabVIEW 2012 SP1 and earlier, and other products. Root cause: the ExportStyle method accepts a full pathname and, when combined...
CVE-2013-5021
Multiple absolute path traversal vulnerabilities in National Instruments cwui.ocx, as used in National Instruments LabWindows/CVI 2012 SP1 and earlier, National Instruments LabVIEW 2012 SP1 and earlier, the Data Analysis component in ABB DataManager 1 through 6.3.6, and other products allow remot...
CVE-2013-5026
CVE-2013-5026 affects National Instruments Lookout 6.5–6.7, where the ActiveX controls lookout650.ocx , lookout660.ocx , and lookout670.ocx allow remote code execution. The root cause is triggering the download of, and calls to, an arbitrary DLL file, enabling an attacker to run arbitrary code on...
CVE-2013-5023
The ActiveX controls in the HelpAsst component in NI Help Links in National Instruments LabWindows/CVI 2012 SP1 and earlier, LabVIEW 2012 SP1 and earlier, and other products allow remote attackers to cause a denial of service by triggering the display of local .chm files...
CVE-2013-5025
The CVE-2013-5025 entry concerns an ActiveX control (exlauncher.dll) in the Help subsystem of National Instruments LabWindows/CVI prior to 2013. The vulnerability allows remote attackers to cause a denial of service by triggering the display of local example files. Exploitation details, affected ...
CVE-2013-5022: Improper Limitation of a Pathname to a Restricted Directory
Absolute path traversal vulnerability in the 3D Graph ActiveX control in cw3dgrph.ocx in National Instruments LabWindows/CVI 2012 SP1 and earlier, LabVIEW 2012 SP1 and earlier, and other products allows remote attackers to create and execute arbitrary files via a full pathname in an argument to t...
CVE-2013-5025: Undefined Security Weakness
An ActiveX control in exlauncher.dll in the Help subsystem in National Instruments LabWindows/CVI before 2013 allows remote attackers to cause a denial of service by triggering the display of local example files...
CVE-2013-5021: Improper Limitation of a Pathname to a Restricted Directory
Multiple absolute path traversal vulnerabilities in National Instruments cwui.ocx, as used in National Instruments LabWindows/CVI 2012 SP1 and earlier, National Instruments LabVIEW 2012 SP1 and earlier, the Data Analysis component in ABB DataManager 1 through 6.3.6, and other products allow remot...
CVE-2013-5024: Undefined Security Weakness
An ActiveX control in NationalInstruments.Help2.dll in National Instruments NI .NET Class Library Help, as used in Measurement Studio 2013 and earlier and other products, allows remote attackers to obtain sensitive information about the existence of registry keys via crafted 1 key-open or 2...
CVE-2013-5026: Undefined Security Weakness
An ActiveX control in lookout650.ocx, lookout660.ocx, and lookout670.ocx in National Instruments Lookout 6.5 through 6.7 allows remote attackers to execute arbitrary code by triggering the download of, and calls to, an arbitrary DLL file...
Oracle Linux 5 / 6 : Unbreakable Enterprise kernel (ELSA-2011-2015)
The remote Oracle Linux 5 / 6 host has packages installed that are affected by multiple vulnerabilities as referenced in the ELSA-2011-2015 advisory. - sctp: fix to calc the INIT/INIT-ACK chunk length correctly is set CVE-2011-1573 - dccp: fix oops on Reset after close CVE-2011-1093 - bridge:...
ABB DataManager National Instruments Multiple ActiveX Controls cwui.ocx ExportStyle() Method Remote Code Execution Vulnerability
This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of ABB DataManager Data Analysis. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within...
National Instruments Device Detection
Binary data 6799.prm...
Secunia Research: Network Instruments Observer SNMP Processing Buffer Overflows
====================================================================== Secunia Research 07/06/2012 - Network Instruments Observer - - SNMP Processing Buffer Overflows - ====================================================================== Table of Contents Affected...
Secunia Research: Network Instruments Observer SNMP OID Processing Denial of Service
====================================================================== Secunia Research 07/06/2012 - Network Instruments Observer - - SNMP OID Processing Denial of Service Vulnerability - ====================================================================== Table of Contents Affected...