611 matches found
nagy-instruments.de Cross Site Scripting vulnerability OBB-3316447
Following the coordinated and responsible vulnerability disclosure guidelines of the ISO 29147 standard, Open Bug Bounty has: a. verified the vulnerability and confirmed its existence; b. notified the website operator about its existence. Technical details of the vulnerability are currently hidde...
CISA Warns of Critical Flaws in Illumina's DNA Sequencing Instruments
The U.S. Cybersecurity and Infrastructure Security Agency CISA has released an Industrial Control Systems ICS medical advisory warning of a critical flaw impacting Illumina medical devices. The issues impact the Universal Copy Service UCS software in the Illumina MiSeqDx, NextSeq 550Dx, iScan, iS...
CVE-2023-1968 CVE-2023-1968
Instruments with Illumina Universal Copy Service v2.x are vulnerable due to binding to an unrestricted IP address. An unauthenticated malicious actor could use UCS to listen on all IP addresses, including those capable of accepting remote communications...
CVE-2023-1966
Illumina Universal Copy Service (UCS) vulnerability CVE-2023-1966 affects UCS v1.x and v2.x, permitting an unauthenticated attacker to upload and execute code at the operating system level. Affects multiple Illumina instruments/control software (e.g., iScan, iSeq 100, MiSeq/MiSeqDx, NextSeq, Nova...
Chip company loses $250m after ransomware hits supply chain
Applied Materials, one of the worlds leading suppliers of equipment, services, and software for the manufacture of semiconductors, has warned that its second-quarter sales are likely to be hurt to the tune of $250 million due to a cybersecurity attack at one of its suppliers. MKS Instruments Inc...
SUSE CVE-2006-1934
Multiple buffer overflows in Ethereal 0.10.x up to 0.10.14 allow remote attackers to cause a denial of service crash and possibly execute arbitrary code via the 1 ALCAP dissector, 2 Network Instruments file code, or 3 NetXray/Windows Sniffer file code...
PT-2022-26518 · National Instruments · Ni Labview Command Line Interface
Name of the Vulnerable Software and Affected Versions: NI LabVIEW Command Line Interface CLI affected versions not specified Description: The issue is related to incorrect default permissions in the installation folder, which may allow an authenticated user to potentially enable escalation of...
swisserinstruments.net Cross Site Scripting vulnerability OBB-3054745
Following the coordinated and responsible vulnerability disclosure guidelines of the ISO 29147 standard, Open Bug Bounty has: a. verified the vulnerability and confirmed its existence; b. notified the website operator about its existence. Technical details of the vulnerability are currently hidde...
CVE-2022-35415
An improper input validation in NI System Configuration Manager before 22.5 may allow a privileged user to potentially enable escalation of privilege via local access...
National Instruments System Configuration Manager 输入验证错误漏洞
National Instruments System Configuration Manager is a configuration manager from National Instruments. A utility program used to monitor and control various NI devices in the system. An input validation error vulnerability exists in National Instruments System Configuration Manager versions prio...
CVE-2021-21966
An information disclosure vulnerability exists in the HTTP Server /ping.html functionality of Texas Instruments CC3200 SimpleLink Solution NWP 2.9.0.0. A specially-crafted HTTP request can lead to an uninitialized read. An attacker can send an HTTP request to trigger this vulnerability...
CVE-2021-21966
An information disclosure vulnerability exists in the HTTP Server /ping.html functionality of Texas Instruments CC3200 SimpleLink Solution NWP 2.9.0.0. A specially-crafted HTTP request can lead to an uninitialized read. An attacker can send an HTTP request to trigger this vulnerability...
Information disclosure
An information disclosure vulnerability exists in the HTTP Server /ping.html functionality of Texas Instruments CC3200 SimpleLink Solution NWP 2.9.0.0. A specially-crafted HTTP request can lead to an uninitialized read. An attacker can send an HTTP request to trigger this vulnerability...
CVE-2021-21966
The TI CC3200 SimpleLink Solution NWP 2.9.0.0 HTTP Server component exposes /ping.html to unauthenticated POST requests. A POST with parameters __SL_P_T.A/B/C can trigger an uninitialized read, causing information disclosure. TALOS-2021-1393 documents the root cause as CWE-457 (Use of Uninitializ...
CVE-2021-21966
An information disclosure vulnerability exists in the HTTP Server /ping.html functionality of Texas Instruments CC3200 SimpleLink Solution NWP 2.9.0.0. A specially-crafted HTTP request can lead to an uninitialized read. An attacker can send an HTTP request to trigger this vulnerability...
Texas Instruments Cc3200 SimpleLink Solution Nwp 环境问题漏洞
Texas Instruments Cc3200 SimpleLink Solution Nwp is a Texas Instruments microcontroller with built-in 2.4Ghz Wifi functionality from Texas Instruments, Inc. An environmental issue vulnerability exists in the Texas Instruments Cc3200 SimpleLink Solution Nwp version 2.9.0.0, which stems from an...
CVE-2021-21966: Use of Uninitialized Variable
An information disclosure vulnerability exists in the HTTP Server /ping.html functionality of Texas Instruments CC3200 SimpleLink Solution NWP 2.9.0.0. A specially-crafted HTTP request can lead to an uninitialized read. An attacker can send an HTTP request to trigger this vulnerability...
Texas Instruments CC3200 SimpleLink Solution HTTP Server /ping.html information disclosure vulnerability
Summary An information disclosure vulnerability exists in the HTTP Server /ping.html functionality of Texas Instruments CC3200 SimpleLink Solution NWP 2.9.0.0. A specially-crafted HTTP request can lead to an uninitialized read. An attacker can send an HTTP request to trigger this vulnerability...
NI Service Locator 代码问题漏洞
NI Service Locator is the NI Service Locator stores registered services and returns data to the client requesting the service. A security vulnerability exists in NI Service Locator versions prior to 18.0 that allows a local user to insert arbitrary code into an unquoted service path and elevate...
sensorinstruments.de Cross Site Scripting vulnerability OBB-2215868
Following the coordinated and responsible vulnerability disclosure guidelines of the ISO 29147 standard, Open Bug Bounty has: a. verified the vulnerability and confirmed its existence; b. notified the website operator about its existence. Technical details of the vulnerability are currently hidde...