15 matches found
*Rockwell Automation AADvance-Trusted SIS Workstation *
RISK EVALUATION Successful exploitation of this vulnerability may allow remote code execution. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as: Minimize network exposure for all control system devices...
CVE-2022-1118
Connected Components Workbench v13.00.00 and prior, ISaGRAF Workbench v6.0 though v6.6.9, and Safety Instrumented System Workstation v1.2 and prior for Trusted Controllers do not limit the objects that can be deserialized. This allows attackers to craft a malicious serialized object that, if open...
VulnCheck KEV: CVE-2022-1118
Connected Components Workbench v13.00.00 and prior, ISaGRAF Workbench v6.0 though v6.6.9, and Safety Instrumented System Workstation v1.2 and prior for Trusted Controllers do not limit the objects that can be deserialized. This allows attackers to craft a malicious serialized object that,...
CVE-2022-29957
The Emerson DeltaV Distributed Control System DCS through 2022-04-29 mishandles authentication. It utilizes several proprietary protocols for a wide variety of functionality. These protocols include Firmware upgrade 18508/TCP, 18518/TCP; Plug-and-Play 18510/UDP; Hawk services 18507/UDP; Managemen...
CVE-2022-1118
Connected Components Workbench v13.00.00 and prior, ISaGRAF Workbench v6.0 though v6.6.9, and Safety Instrumented System Workstation v1.2 and prior for Trusted Controllers do not limit the objects that can be deserialized. This allows attackers to craft a malicious serialized object that, if open...
Remote code execution
Connected Components Workbench v13.00.00 and prior, ISaGRAF Workbench v6.0 though v6.6.9, and Safety Instrumented System Workstation v1.2 and prior for Trusted Controllers do not limit the objects that can be deserialized. This allows attackers to craft a malicious serialized object that, if open...
CVE-2022-1118 Rockwell Automation ISaGRAF Deserialization of Untrusted Data
Connected Components Workbench v13.00.00 and prior, ISaGRAF Workbench v6.0 though v6.6.9, and Safety Instrumented System Workstation v1.2 and prior for Trusted Controllers do not limit the objects that can be deserialized. This allows attackers to craft a malicious serialized object that, if open...
CVE-2022-1118
CVE-2022-1118 affects Rockwell Automation components: Connected Components Workbench (v13.00.00 and prior), ISaGRAF Workbench (v6.0–v6.6.9), and Safety Instrumented System Workstation (v1.2 and prior for Trusted Controllers). The issue is deserialization of untrusted data, allowing a crafted seri...
Denial of Service Vulnerability in the MP3009 Processor of the Schneider Tricon Safety Instrumented System (CNVD-2020-70793)
The Tricon Safety Instrumented System is a safety instrumented system from Schneider Electric Co. The MP3009 module is the processor module for the Schneider Tricon Safety Instrumented System. A denial of service vulnerability exists in the MP3009 processor of the Schneider Tricon Safety...
Denial of Service Vulnerability in the MP3009 Processor of the Schneider Tricon Safety Instrumented System (CNVD-2020-67123)
The Tricon Safety Instrumented System is a safety instrumented system from Schneider Electric Co. The MP3009 module is the processor module for the Schneider Tricon Safety Instrumented System. A denial of service vulnerability exists in the MP3009 processor of the Schneider Tricon Safety...
Denial of Service Vulnerability in the MP3009 Processor of the Schneider Tricon Safety Instrumented System (CNVD-2020-67121)
The Tricon Safety Instrumented System is a safety instrumented system from Schneider Electric Co. The MP3009 module is the processor module for the Schneider Tricon Safety Instrumented System. A denial of service vulnerability exists in the MP3009 processor of the Schneider Tricon Safety...
Denial of Service Vulnerability in the MP3009 Processor of the Schneider Tricon Safety Instrumented System (CNVD-2020-67122)
The Tricon Safety Instrumented System is a safety instrumented system from Schneider Electric Co. The MP3009 module is the processor module for the Schneider Tricon Safety Instrumented System. A denial of service vulnerability exists in the MP3009 processor of the Schneider Tricon Safety...
Authentication Bypass Vulnerability in Triconex SIS System
The Triconex SIS system is a modern programmable logic and process controller. An authentication bypass vulnerability exists in the Triconex SIS system, which could be exploited by an unauthorized attacker to gain access to the controller...
TRISIS Group, Known for Physical Destruction, Targets U.S. Electric Companies
XENOTIME, the APT group behind the TRISIS industrial control system ICS event, has expanded its focus beyond the oil and gas industries, according to researchers. The group has recently been seen probing the networks of electric utility organizations in the U.S. and elsewhere – perhaps a precurso...
Yokogawa Multiple Products Vulnerabilities
OVERVIEW Yokogawa reports that several buffer overflow vulnerabilities affect several of its products. Juan Vazquez of Rapid7 Inc.,Rapid7 Inc., http://www.rapid7.com, web site last accessed May 13, 2014. and independent researcher Julian Vilas Diaz reported to CERT/CC that they identified several...