73 matches found
PT-2021-2232 · Picotcp · Picotcp
Name of the Vulnerable Software and Affected Versions: PicoTCP version 1.7.0 Description: The issue is related to the improper randomness of TCP Initial Sequence Numbers ISNs in the PicoTCP stack implementation. This could potentially allow a remote attacker to gain unauthorized access to protect...
PT-2021-2224 · Silicon · Uc/Tcp-Ip
Name of the Vulnerable Software and Affected Versions: Silicon Labs uC/TCP-IP version 3.6.0 Description: The issue is related to the improper randomness of TCP Initial Sequence Numbers ISNs in the stack protocol used by uC/OS and uC/TCP-IP. This could allow a remote attacker to gain unauthorized...
Multiple Embedded TCP/IP Stacks (Update B)
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Multiple Equipment: Nut/Net, CycloneTCP, NDKTCPIP, FNET, uIP-Contiki-OS, uC/TCP-IP, uIP-Contiki-NG, uIP, picoTCP-NG, picoTCP, MPLAB Net, Nucleus NET, Nucleus ReadyStart Vulnerabilities: Use of...
CVE-2020-28388
A vulnerability has been identified in APOGEE PXC Compact BACnet All versions V3.5.5, APOGEE PXC Compact P2 Ethernet All versions V2.8.20, APOGEE PXC Modular BACnet All versions V3.5.5, APOGEE PXC Modular P2 Ethernet All versions V2.8.20, Nucleus NET All versions V5.2, Nucleus ReadyStart V3 All...
Buffer overflow
A vulnerability has been identified in APOGEE PXC Compact BACnet All versions V3.5.5, APOGEE PXC Compact P2 Ethernet All versions V2.8.20, APOGEE PXC Modular BACnet All versions V3.5.5, APOGEE PXC Modular P2 Ethernet All versions V2.8.20, Nucleus NET All versions V5.2, Nucleus ReadyStart V3 All...
PT-2021-7763 · Unknown · Nucleus Net +7
Name of the Vulnerable Software and Affected Versions: APOGEE PXC Compact BACnet versions prior to V3.5.5 APOGEE PXC Compact P2 Ethernet versions prior to V2.8.20 APOGEE PXC Modular BACnet versions prior to V3.5.5 APOGEE PXC Modular P2 Ethernet versions prior to V2.8.20 Nucleus NET versions prior...
CVE-2020-28388
A vulnerability has been identified in APOGEE PXC Compact BACnet All versions V3.5.5, APOGEE PXC Compact P2 Ethernet All versions V2.8.20, APOGEE PXC Modular BACnet All versions V3.5.5, APOGEE PXC Modular P2 Ethernet All versions V2.8.20, Nucleus NET All versions V5.2, Nucleus ReadyStart V3 All...
Rockwell Automation/Allen-Bradley MicroLogix Controllers <= 16.00 Predictable Value Range
Binary data 720125.prm...
CVE-2017-7901
A Predictable Value Range from Previous Values issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series...
CVE-2017-7901
A Predictable Value Range from Previous Values issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series...
PT-2017-17982 · Rockwell Automation · Micrologix 1100 +1
Name of the Vulnerable Software and Affected Versions: Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers versions 16.00 and prior Rockwell Automation Allen-Bradley MicroLogix 1400 programmable logic controllers versions 16.00 and prior Description: A Predictable Val...
CVE-2017-7901: Predictable Value Range from Previous Values
A Predictable Value Range from Previous Values issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series...
CVE-2017-6030: Predictable Value Range from Previous Values
A predictable value range from previous values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected...
Wind River VxWorks TCP Predictability Vulnerability
According to its self-reported version, the Wind River VxWorks remote device is potentially affected by a TCP predictability vulnerability that allows a man-in-the-middle attacker to predict the TCP initial sequence numbers based on previous values. This can exploited to spoof or disrupt TCP...
CVE-2014-5409 GE Hydran M2 Predictable Value Range from Previous Values
The 17046 Ethernet card before 94450214LFMT100SEM-L.R3-CL for the GE Digital Energy Hydran M2 does not properly generate random values for TCP Initial Sequence Numbers ISNs, which makes it easier for remote attackers to spoof packets by predicting these values...
CVE-2014-5409
CVE-2014-5409 affects GE Digital Energy Hydran M2 devices with the 17046 Ethernet option. The 17046 Ethernet card before 94450214LFMT100SEM-L.R3-CL does not generate proper random TCP Initial Sequence Numbers, enabling an attacker to predict sequence values and spoof packets. Exploitation could b...
CVE-2014-5409: Predictable Value Range from Previous Values
The 17046 Ethernet card before 94450214LFMT100SEM-L.R3-CL for the GE Digital Energy Hydran M2 does not properly generate random values for TCP Initial Sequence Numbers ISNs, which makes it easier for remote attackers to spoof packets by predicting these values...
CVE-2001-0163: Undefined Security Weakness
Cisco AP340 base station produces predictable TCP Initial Sequence Numbers ISNs, which allows remote attackers to spoof or hijack TCP connections...
CVE-2001-0162: Undefined Security Weakness
WinCE 3.0.9348 generates predictable TCP Initial Sequence Numbers ISNs, which allows remote attackers to spoof or hijack TCP connections...
CVE-2002-1463
Symantec Raptor Firewall 6.5 and 6.5.3, Enterprise Firewall 6.5.2 and 7.0, VelociRaptor Models 500/700/1000 and 1100/1200/1300, and Gateway Security 5110/5200/5300 generate easily predictable initial sequence numbers ISN, which allows remote attackers to spoof connections...