Lucene search
+L

282 matches found

Prion
Prion
added 2015/07/06 7:59 p.m.21 views

Design/Logic Flaw

Hospira LifeCare PCA Infusion System before 7.0 stores private keys and certificates, which has unspecified impact and attack vectors...

4.6CVSS7.2AI score0.00544EPSS
SaveExploits0References3Affected Software1
CVE
CVE
added 2015/07/06 7:10 p.m.58 views

CVE-2015-3958

CVE-2015-3958 affects Hospira LifeCare PCA Infusion System (Version 5.0 and earlier). The issue enables remote denial-of-service via a flood of TCP packets, forcing manual reboot. Impact is tied to vulnerable AppWeb/network services; exploitation details are discussed in ICS-CERT/NVD entries. Mit...

7.8CVSS6.9AI score0.02612EPSS
SaveExploits0References3Affected Software1
Cvelist
Cvelist
added 2015/07/06 7:10 p.m.27 views

CVE-2015-3958

Hospira LifeCare PCA Infusion System 5.0 and earlier, and possibly other versions, allows remote attackers to cause a denial of service forced manual reboot via a flood of TCP packets...

6.7AI score0.02612EPSS
SaveExploits0References3
CVE
CVE
added 2015/07/06 7:10 p.m.70 views

CVE-2015-3957

CVE-2015-3957 applies to Hospira LifeCare PCA Infusion System prior to v7.0, where private keys and certificates are stored on the device. The public-facing details in the connected ICS/NIST sources describe a stack-based buffer overflow risk and related UI/network exposure in older LifeCare PCA ...

4.6CVSS6.8AI score0.00544EPSS
SaveExploits0References3Affected Software3
CVE
CVE
added 2015/07/06 7:10 p.m.57 views

CVE-2014-5406

Hospira LifeCare PCA Infusion System prior to version 7.0 is affected by CVE-2014-5406. The device’s network-facing components (TELNET, HTTP/HTTPS, UPNP) do not validate or restrict incoming traffic, enabling an unauthenticated remote attacker to modify drug libraries, software updates, or pump c...

9.3CVSS6.6AI score0.01242EPSS
SaveExploits0References5Affected Software1
Cvelist
Cvelist
added 2015/07/06 7:10 p.m.28 views

CVE-2014-5406 Hospira LifeCare PCA Infusion System

The Hospira LifeCare PCA Infusion System before 7.0 does not validate network traffic associated with sending a 1 drug library, 2 software update, or 3 configuration change, which allows remote attackers to modify settings or medication data via packets on the a TELNET, b HTTP, c HTTPS, or d UPNP...

7.6CVSS7.4AI score0.01242EPSS
SaveExploits0References4
Cvelist
Cvelist
added 2015/07/06 7:10 p.m.27 views

CVE-2015-3955

Stack-based buffer overflow in Hospira LifeCare PCA Infusion System 5.0 and earlier, and possibly other versions, allows remote attackers to execute arbitrary code via unspecified vectors...

8.2AI score0.0675EPSS
SaveExploits0References3
CVE
CVE
added 2015/07/06 7:10 p.m.94 views

CVE-2015-1011

Hospira LifeCare PCA Infusion System (Version 5.0 and earlier) is affected by multiple vulnerabilities, notably hardcoded credentials and insecure data handling. Technical details from ICS-CERT/NVD describe improper authorization (CWE-285) that could allow unauthenticated users root access and in...

5CVSS6.8AI score0.02228EPSS
SaveExploits0References2Affected Software1
CNVD
CNVD
added 2015/06/26 12:00 a.m.9 views

Hospira Lifecare PCA Infusion Pump Security Bypass Vulnerability

Hospira Lifecare PCA infusion Pump is a suite of smart infusion pump software from Hospira, USA. A security bypass vulnerability exists in Hospira Lifecare PCA Infusion Pump. An attacker could use this vulnerability to bypass authentication mechanisms and gain access to affected devices...

5CVSS7.1AI score0.02228EPSS
SaveExploits0References1
CNVD
CNVD
added 2015/06/26 12:00 a.m.8 views

Hospira Lifecare PCA Infusion Pump Information Disclosure Vulnerability

Hospira Lifecare PCA infusion Pump is a suite of smart infusion pump software from Hospira, USA. An information disclosure vulnerability exists in Hospira Lifecare PCA Infusion Pump. An attacker could exploit this vulnerability to gain access to sensitive information...

7.5CVSS6.4AI score0.00771EPSS
SaveExploits0References1
CNVD
CNVD
added 2015/06/24 12:00 a.m.7 views

Multiple Hospira Product Security Bypass Vulnerabilities

The Hospira Plum A+ Infusion System, Plum A+3 Infusion System and Symbiq Infusion System are all intelligent infusion systems from Hospira. A security bypass vulnerability exists in multiple Hospira products. An attacker could exploit the vulnerability to bypass security restrictions and perform...

10CVSS6.9AI score0.00954EPSS
SaveExploits0References1
CNVD
CNVD
added 2015/06/24 12:00 a.m.10 views

Authentication Bypass Vulnerability in Multiple Hospira Products

The Hospira Plum A+ Infusion System, Plum A+3 Infusion System and Symbiq Infusion System are all intelligent infusion systems from Hospira. An authentication bypass vulnerability exists in multiple Hospira products. An attacker could use this vulnerability to bypass the authentication mechanism a...

10CVSS7.1AI score0.02036EPSS
SaveExploits0References1
CNVD
CNVD
added 2015/06/24 12:00 a.m.8 views

Information Disclosure Vulnerability in Multiple Hospira Products

The Hospira Plum A+ Infusion System, Plum A+3 Infusion System and Symbiq Infusion System are all intelligent infusion systems from Hospira. An information disclosure vulnerability exists in multiple Hospira products. An attacker could exploit this vulnerability to obtain sensitive information...

7.5CVSS6.2AI score0.01008EPSS
SaveExploits0References1
CNVD
CNVD
added 2015/06/24 12:00 a.m.7 views

Local Security Bypass Vulnerability in Multiple Hospira Products

The Hospira Plum A+ Infusion System, Plum A+3 Infusion System and Symbiq Infusion System are all intelligent infusion systems from Hospira. A local security bypass vulnerability exists in multiple Hospira products. A local attacker could exploit this vulnerability to bypass security restrictions...

4.6CVSS6.7AI score0.00544EPSS
SaveExploits0References1
CNVD
CNVD
added 2015/06/24 12:00 a.m.10 views

Stack Buffer Overflow Vulnerability in Multiple Hospira Products

The Hospira Plum A+ Infusion System, Plum A+3 Infusion System and Symbiq Infusion System are all intelligent infusion systems from Hospira. A stack buffer overflow vulnerability exists in multiple Hospira products due to the program failing to perform proper boundary checks on user-submitted inpu...

10CVSS8.1AI score0.0675EPSS
SaveExploits0References1
CNVD
CNVD
added 2015/06/24 12:00 a.m.7 views

Remote Denial of Service Vulnerability in Multiple Hospira Products

The Hospira Plum A+ Infusion System, Plum A+3 Infusion System and Symbiq Infusion System are all intelligent infusion systems from Hospira. A remote denial of service vulnerability exists in multiple Hospira products. An attacker could exploit this vulnerability to cause a denial of service...

7.8CVSS6.8AI score0.02612EPSS
SaveExploits0References1
CNVD
CNVD
added 2015/06/24 12:00 a.m.8 views

Hardcoded Password Security Bypass Vulnerability in Multiple Hospira Products

The Hospira Plum A+ Infusion System, Plum A+3 Infusion System and Symbiq Infusion System are all intelligent infusion systems from Hospira. A security bypass vulnerability exists in multiple Hospira products. An attacker could exploit this vulnerability to bypass security restrictions and gain...

10CVSS7AI score0.01972EPSS
SaveExploits0References1
CNVD
CNVD
added 2015/05/19 12:00 a.m.6 views

Hospira LifeCare PCA Infusion System Security Restriction Bypass Vulnerability

The Hospira LifeCare PCA Infusion System is an IV infusion pump that delivers medications to patients. Hospira LifeCare PCA Infusion System 5.0 and earlier versions are vulnerable to a data authenticity validation vulnerability in their implementation by uploading software updates, configuration...

9.3CVSS6.8AI score0.01242EPSS
SaveExploits0References1
CNVD
CNVD
added 2015/05/01 12:00 a.m.8 views

Hospira Lifecare PCA Infusion Pump Arbitrary Command Execution Vulnerability

Hospira Lifecare PCA infusion pump is a suite of smart infusion pump software from Hospira USA. Failure to perform authentication for Telnet sessions in Hospira Lifecare PCA infusion pumps running SW ver 412 allows a remote attacker to gain root privileges by accessing the telnet service...

10CVSS7.4AI score0.05064EPSS
SaveExploits0References1
NVD
NVD
added 2015/04/29 11:59 p.m.16 views

CVE-2015-3459

The communication module on the Hospira LifeCare PCA Infusion System before 7.0 does not require authentication for root TELNET sessions, which allows remote attackers to modify the pump configuration via unspecified commands...

10CVSS7.6AI score0.05064EPSS
SaveExploits0References8
Rows per page
Query Builder