Lucene search
+L

100 matches found

OSV
OSV
•added 2019/10/28 1:15 p.m.•12 views

CVE-2019-14928

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A number of stored cross-site script XSS vulnerabilities allow an attacker to inject malicious code directly into the application. An example input variable vulnerable to...

5.4CVSS6.1AI score0.44149EPSS
SaveExploits1References2
NVD
NVD
•added 2019/10/28 1:15 p.m.•30 views

CVE-2019-14930

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Undocumented hard-coded user passwords for root, ineaadmin, mitsadmin, and maint could allow an attacker to gain unauthorised access to the RTU. Also, the accounts ineaadmin...

10CVSS9.9AI score0.02343EPSS
SaveExploits1References2
NVD
NVD
•added 2019/10/28 1:15 p.m.•73 views

CVE-2019-14928

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A number of stored cross-site script XSS vulnerabilities allow an attacker to inject malicious code directly into the application. An example input variable vulnerable to...

5.4CVSS6.4AI score0.44149EPSS
SaveExploits1References2
NVD
NVD
•added 2019/10/28 1:15 p.m.•31 views

CVE-2019-14925

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A world-readable /usr/smartrtu/init/settings.xml configuration file on the file system allows an attacker to read sensitive configuration settings such as usernames,...

6.5CVSS7.1AI score0.0126EPSS
SaveExploits1References2
NVD
NVD
•added 2019/10/28 1:15 p.m.•33 views

CVE-2019-14929

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Stored cleartext passwords could allow an unauthenticated attacker to obtain configured username and password combinations on the RTU due to the weak credentials management ...

9.8CVSS9.7AI score0.01936EPSS
SaveExploits1References2
Prion
Prion
•added 2019/10/28 1:15 p.m.•30 views

Default credentials

An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Stored cleartext passwords could allow an unauthenticated attacker to obtain configured username and password combinations on the RTU due to the weak credentials management on the RTU. ...

5CVSS9.6AI score0.01936EPSS
SaveExploits1References2Affected Software2
Prion
Prion
•added 2019/10/28 1:15 p.m.•32 views

Design/Logic Flaw

An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A world-readable /usr/smartrtu/init/settings.xml configuration file on the file system allows an attacker to read sensitive configuration settings such as usernames, passwords, and othe...

4CVSS7AI score0.0126EPSS
SaveExploits1References2Affected Software2
Prion
Prion
•added 2019/10/28 1:15 p.m.•28 views

Hardcoded credentials

An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Hard-coded SSH keys allow an attacker to gain unauthorised access or disclose encrypted data on the RTU due to the keys not being regenerated on initial installation or with firmware...

7.5CVSS9.6AI score0.02085EPSS
SaveExploits1References2Affected Software2
Prion
Prion
•added 2019/10/28 1:15 p.m.•25 views

Hardcoded credentials

An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Undocumented hard-coded user passwords for root, ineaadmin, mitsadmin, and maint could allow an attacker to gain unauthorised access to the RTU. Also, the accounts ineaadmin and mitsadm...

10CVSS9.8AI score0.02343EPSS
SaveExploits1References2Affected Software2
Prion
Prion
•added 2019/10/28 1:15 p.m.•27 views

Cross site scripting

An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A number of stored cross-site script XSS vulnerabilities allow an attacker to inject malicious code directly into the application. An example input variable vulnerable to stored XSS is...

3.5CVSS6.2AI score0.44149EPSS
SaveExploits1References2Affected Software2
Prion
Prion
•added 2019/10/28 1:15 p.m.•24 views

Design/Logic Flaw

An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU's configuration file which contains data such as usernames, passwords, and oth...

5CVSS7.7AI score0.41847EPSS
SaveExploits3References2Affected Software2
Prion
Prion
•added 2019/10/28 1:15 p.m.•28 views

Command injection

An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote OS Command Injection vulnerability allows an attacker to execute arbitrary commands on the RTU due to the passing of unsafe user supplied data to the RTU's...

10CVSS10AI score0.58361EPSS
SaveExploits3References2Affected Software2
Cvelist
Cvelist
•added 2019/10/28 12:12 p.m.•56 views

CVE-2019-14925

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A world-readable /usr/smartrtu/init/settings.xml configuration file on the file system allows an attacker to read sensitive configuration settings such as usernames,...

6.4AI score0.0126EPSS
SaveExploits1References2
CVE
CVE
•added 2019/10/28 12:12 p.m.•87 views

CVE-2019-14925

CVE-2019-14925 affects Mitsubishi Electric Europe B.V. ME-RTU devices up to v2.02 and INEA ME-RTU devices up to v3.0. The issue is insecure world-readable permissions on /usr/smartrtu/init/settings.xml, allowing access to sensitive configuration data (e.g., usernames and passwords). Public disclo...

6.5CVSS6.7AI score0.0126EPSS
SaveExploits1References2Affected Software1
CVE
CVE
•added 2019/10/28 12:11 p.m.•80 views

CVE-2019-14929

CVE-2019-14929 affects Mitsubishi Electric Europe B.V. smartRTU ME-RTU devices (firmware up to 2.02) and INEA ME-RTU devices (up to 3.0). The root cause is unprotected storage of credentials (passwords stored in plaintext) due to weak credential management, enabling an unauthenticated attacker to...

9.8CVSS9.7AI score0.01936EPSS
SaveExploits1References2Affected Software1
Cvelist
Cvelist
•added 2019/10/28 12:11 p.m.•48 views

CVE-2019-14929

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Stored cleartext passwords could allow an unauthenticated attacker to obtain configured username and password combinations on the RTU due to the weak credentials management ...

9.7AI score0.01936EPSS
SaveExploits1References2
Cvelist
Cvelist
•added 2019/10/28 12:10 p.m.•42 views

CVE-2019-14930

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Undocumented hard-coded user passwords for root, ineaadmin, mitsadmin, and maint could allow an attacker to gain unauthorised access to the RTU. Also, the accounts ineaadmin...

9.9AI score0.02343EPSS
SaveExploits1References2
CVE
CVE
•added 2019/10/28 12:10 p.m.•87 views

CVE-2019-14930

CVE-2019-14930 affects Mitsubishi Electric Europe B.V. ME-RTU (through 2.02) and INEA ME-RTU (through 3.0). The issue arises from undocumented hard-coded credentials for root, ineaadmin, mitsadmin, and maint, enabling unauthenticated access to the RTU. Additionally, ineaadmin and mitsadmin can es...

10CVSS9.9AI score0.02343EPSS
SaveExploits1References2Affected Software1
Cvelist
Cvelist
•added 2019/10/28 12:10 p.m.•53 views

CVE-2019-14926

An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Hard-coded SSH keys allow an attacker to gain unauthorised access or disclose encrypted data on the RTU due to the keys not being regenerated on initial installation or with...

9.7AI score0.02085EPSS
SaveExploits1References2
CVE
CVE
•added 2019/10/28 12:10 p.m.•84 views

CVE-2019-14926

CVE-2019-14926 concerns hard-coded SSH keys in Mitsubishi Electric ME-RTU (firmware up to 2.02) and INEA ME-RTU (up to 3.0). The root cause is static private-key values stored in /etc/ssh/ssh_host_rsa_key, /etc/ssh/ssh_host_ecdsa_key, and /etc/ssh/ssh_host_dsa_key that are publicly available from...

9.8CVSS9.7AI score0.02085EPSS
SaveExploits1References2Affected Software1
Rows per page
Query Builder