500 matches found
CVE-2024-46844
creationtimestamp| type| source ---|---|--- 2025-08-14 10:00:00+00:00| seen| https://www.cisa.gov/news-events/ics-advisories/icsa-25-226-07...
CVE-2024-47740
creationtimestamp| type| source ---|---|--- 2025-08-14 10:00:00+00:00| seen| https://www.cisa.gov/news-events/ics-advisories/icsa-25-226-07...
CVE-2024-46689
creationtimestamp| type| source ---|---|--- 2025-08-14 10:00:00+00:00| seen| https://www.cisa.gov/news-events/ics-advisories/icsa-25-226-07...
CVE-2024-46817
creationtimestamp| type| source ---|---|--- 2025-08-14 10:00:00+00:00| seen| https://www.cisa.gov/news-events/ics-advisories/icsa-25-226-07...
CVE-2024-26763
creationtimestamp| type| source ---|---|--- 2025-08-14 10:00:00+00:00| seen| https://www.cisa.gov/news-events/ics-advisories/icsa-25-226-15...
CVE-2024-41034
creationtimestamp| type| source ---|---|--- 2025-08-14 10:00:00+00:00| seen| https://www.cisa.gov/news-events/ics-advisories/icsa-25-226-07...
CVE-2024-40958
creationtimestamp| type| source ---|---|--- 2025-08-14 10:00:00+00:00| seen| https://www.cisa.gov/news-events/ics-advisories/icsa-25-226-07...
CVE-2024-49983
creationtimestamp| type| source ---|---|--- 2025-08-14 10:00:00+00:00| seen| https://www.cisa.gov/news-events/ics-advisories/icsa-25-226-07...
CVE-2024-49977
creationtimestamp| type| source ---|---|--- 2025-08-14 10:00:00+00:00| seen| https://www.cisa.gov/news-events/ics-advisories/icsa-25-226-07...
CVE-2024-40901
creationtimestamp| type| source ---|---|--- 2025-08-14 10:00:00+00:00| seen| https://www.cisa.gov/news-events/ics-advisories/icsa-25-226-07...
Rockwell Automation 1756-EN4TR, 1756-EN4TRXT (Update B)
RISK EVALUATION Successful exploitation of these vulnerabilities could result in an attacker causing a denial of service condition. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as: Minimize network...
isf
This is a Python-based exploitation framework called ISF Industrial Exploitation Framework that is similar to Metasploit. It is designed for industrial control system ICS exploitation and is used for testing and demonstrating vulnerabilities in ICS devices. The framework is based on the open-sour...
CVE-2025-29628
creationtimestamp| type| source ---|---|--- 2025-07-04 21:00:04+00:00| published-proof-of-concept| Telegram/OollRHxvoptfGlV2c1gbdC6jSDWMy1y9qQszI5U7KKS9Kqc 2026-02-24 11:00:00+00:00| seen| https://www.cisa.gov/news-events/ics-advisories/icsa-26-055-03 2026-04-02 16:00:04+00:00| seen|...
CVE-2025-29629
creationtimestamp| type| source ---|---|--- 2025-07-04 21:00:04+00:00| published-proof-of-concept| Telegram/OollRHxvoptfGlV2c1gbdC6jSDWMy1y9qQszI5U7KKS9Kqc 2026-02-24 11:00:00+00:00| seen| https://www.cisa.gov/news-events/ics-advisories/icsa-26-055-03 2026-04-02 16:00:04+00:00| seen|...
CVE-2025-29631
creationtimestamp| type| source ---|---|--- 2025-07-04 21:00:04+00:00| published-proof-of-concept| Telegram/OollRHxvoptfGlV2c1gbdC6jSDWMy1y9qQszI5U7KKS9Kqc 2026-02-24 11:00:00+00:00| seen| https://www.cisa.gov/news-events/ics-advisories/icsa-26-055-03 2026-04-02 16:00:04+00:00| seen|...
The vulnerability of the SCADA system Pult.online, related to inconsistencies in responses to incoming requests, allows a intruder to gain unauthorized access to protected information.
The vulnerability of the SCADA system Pult.online is related to inconsistencies in responses to incoming requests. Exploiting this vulnerability can allow a malicious actor, operating remotely, to gain unauthorized access to protected information by sending a specially crafted POST request...
CVE-2020-16850
Mitsubishi MELSEC iQ-R Series PLCs with firmware 49 allow an unauthenticated attacker to halt the industrial process by sending a crafted packet over the network. This denial of service attack exposes Improper Input Validation. After halting, physical access to the PLC is required in order to...
CISA Releases Seven Industrial Control Systems Advisories
CISA released seven Industrial Control Systems ICS advisories on April 24, 2025. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS. ICSA-25-114-01 Schneider Electric Modicon Controllers ICSA-25-114-02 ALBEDO Telecom Net.Time -...
Siemens TeleControl Server Basic SQL Injection Vulnerability (CNVD-2025-08353)
Siemens TeleControl Server Basic is an industrial remote controller from Siemens, Germany. Siemens TeleControl Server Basic suffers from a SQL injection vulnerability that originates from a SQL injection in the internal method UpdateDatabaseSettings, which can be exploited by an attacker to bypas...
Siemens TeleControl Server Basic SQL注入漏洞
Siemens TeleControl Server Basic is an industrial remote controller from Siemens, Germany. Siemens TeleControl Server Basic suffers from a SQL injection vulnerability that originates from a SQL injection in the internal method LockTcmSettings, which can be exploited by an attacker to bypass...