Lucene search
+L

57 matches found

CNNVD
CNNVD
added 2026/03/18 12:0 a.m.8 views

Phoenix Contact多款产品 跨站脚本漏洞

PHOENIX CONTACT FL SWITCH and PHOENIX CONTACT FL NAT are products of the German company PHOENIX CONTACT. PHOENIX CONTACT FL SWITCH is an industrial-grade Ethernet switch. PHOENIX CONTACT FL NAT is a series of industrial security gateways. Several products from Phoenix Contact have a cross-site...

7.1CVSS5.7AI score0.00253EPSS
Exploits0References1
CNNVD
CNNVD
added 2025/12/10 12:0 a.m.5 views

WAGO Indsutrial-Managed-Switches 安全漏洞

WAGO Indsutrial-Managed-Switches is a series of high-performance network devices from WAGO, Germany. A security vulnerability exists in WAGO Indsutrial-Managed-Switches, which stems from an unsafe sscanf call in the checkaccount function, which could lead to full control of the device...

9.8CVSS6.7AI score0.00376EPSS
Exploits0References1
EUVD
EUVD
added 2025/10/07 12:30 a.m.5 views

EUVD-2016-10145

Malware in sbrugna...

10CVSS9.1AI score0.01563EPSS
Exploits0References2
BDU FSTEC
BDU FSTEC
added 2025/05/23 12:0 a.m.15 views

The vulnerability of SCALANCE W-700 IEEE 802.11ax industrial switches, related to insufficient verification of input data, allows a intruder to execute arbitrary commands.

The vulnerability of SCALANCE W-700 IEEE 802.11ax industrial switches lies in insufficient validation of input data. Exploiting this vulnerability allows a remote attacker to execute arbitrary commands...

9CVSS5.9AI score0.0082EPSS
Exploits0References2Affected Software17
BDU FSTEC
BDU FSTEC
added 2025/05/16 12:0 a.m.8 views

The vulnerability of the VLAN (Virtual Local Area Network) technology in the microprogramming-based industrial wireless switches ABB ARG600, ARP600, ARR600, and ARC600 allows attackers to compromise the confidentiality, integrity, and accessibility of protected information.

The vulnerability of the VLAN Virtual Local Area Network technology in the microprogramming-based industrial wireless switches ABB ARG600, ARP600, ARR600, and ARC600 is related to incorrect initialization of resources. Exploiting this vulnerability can allow an attacker to compromise the...

10CVSS7.8AI score0.00819EPSS
Exploits0References2Affected Software4
BDU FSTEC
BDU FSTEC
added 2025/03/18 12:0 a.m.14 views

The vulnerability of Siemens Scalance LPE9403 industrial switches’ microprogramming software lies in the lack of measures to neutralize special elements, allowing attackers to execute arbitrary code.

The vulnerability of Siemens Scalance LPE9403 industrial switches’ microprogramming software is related to the lack of measures taken to neutralize special elements. Exploiting this vulnerability allows a remote attacker to execute arbitrary code...

9CVSS5.9AI score0.00666EPSS
Exploits0References2Affected Software1
CNNVD
CNNVD
added 2025/03/11 12:0 a.m.4 views

Siemens SCALANCE LPE9403 路径遍历漏洞

Siemens SCALANCE and Siemens SCALANCE LPE9403 are both products of Siemens, Germany.Siemens SCALANCE is a series of Ethernet switches. It connects to Industrial Control System ICS devices, including Programmable Logic Controllers PLCs and Human Machine Interface HMI systems.Siemens SCALANCE LPE94...

5.1CVSS6.4AI score0.00375EPSS
Exploits0References2
BDU FSTEC
BDU FSTEC
added 2024/07/23 12:0 a.m.9 views

The vulnerability of Siemens SCALANCE industrial switches, related to the ability to bypass authentication through spoofing, allows attackers to enhance their privileges.

The vulnerability of Siemens SCALANCE industrial switches relates to the ability to bypass authentication through spoofing. Exploiting this vulnerability can allow a malicious actor to gain increased privileges...

8.4CVSS5.5AI score0.00234EPSS
Exploits0References2
BDU FSTEC
BDU FSTEC
added 2024/07/17 12:0 a.m.8 views

The vulnerability of Siemens SCALANCE industrial switches’ microprogramming software, related to bypassing authentication through spoofing, allows attackers to gain unauthorized access to protected information.

The vulnerability of Siemens SCALANCE industrial switches’ microprogramming software relates to the ability to bypass authentication through spoofing. Exploiting this vulnerability can allow an intruder operating remotely to gain unauthorized access to protected information...

6.1CVSS5.5AI score0.00214EPSS
Exploits0References2
CNNVD
CNNVD
added 2024/07/09 12:0 a.m.5 views

Siemens RUGGEDCOM 安全漏洞

Siemens RuggedCom ROS is an operating system from Siemens, Germany, used in the RuggedCom series of switches. An incorrect privilege assignment vulnerability exists in Siemens RUGGEDCOM ROS, which can be exploited by an attacker to create a remote shell for an affected system...

7.5CVSS6.9AI score0.00344EPSS
Exploits0References4
BDU FSTEC
BDU FSTEC
added 2023/11/22 12:0 a.m.10 views

The vulnerability of Siemens SCALANCE industrial switches’ microprogramming software, related to the use of a weak password hash function, allows attackers to modify the device’s configuration.

The vulnerability of Siemens SCALANCE industrial switches’ microprogrammed software is related to the use of a weak password hash function. Exploiting this vulnerability could allow an attacker to remotely modify the device’s configuration...

6.1CVSS6.3AI score0.00446EPSS
Exploits0References3Affected Software40
Positive Technologies
Positive Technologies
added 2023/11/14 12:0 a.m.5 views

PT-2023-6993 · Siemens · Scalance M826-2 Shdsl-Router +16

Name of the Vulnerable Software and Affected Versions: RUGGEDCOM RM1224 LTE4G EU versions V8.0 RUGGEDCOM RM1224 LTE4G NAM versions V8.0 SCALANCE M804PB versions V8.0 SCALANCE M812-1 ADSL-Router versions V8.0 SCALANCE M816-1 ADSL-Router versions V8.0 SCALANCE M826-2 SHDSL-Router versions V8.0...

5.9CVSS6.6AI score0.00879EPSS
Exploits0References11
CNNVD
CNNVD
added 2023/11/14 12:0 a.m.4 views

Siemens SCALANCE 安全漏洞

The SCALANCE M-800, MUM-800 and S615 and the RUGGEDCOM RM1224 are industrial routers.The SCALANCE W products are wireless communication devices for connecting industrial components, such as Programmable Logic Controllers PLCs or Human Machine Interfaces HMIs, that comply with the IEEE 802.11...

4.3CVSS6.7AI score0.00643EPSS
Exploits0References9
CNVD
CNVD
added 2023/02/06 12:0 a.m.10 views

Moxa SDS-3008 cross-site scripting vulnerability (CNVD-2023-58304)

Moxa SDS-3008 is a series of industrial switches from MOXA China. The Moxa SDS-3008 suffers from a cross-site scripting vulnerability that can be exploited by an attacker to send a specially crafted HTTP request resulting in arbitrary Javascript execution...

5.4CVSS6.3AI score0.01084EPSS
Exploits1References1
CNVD
CNVD
added 2023/02/06 12:0 a.m.10 views

Moxa SDS-3008 Plaintext Transfer Vulnerability

Moxa SDS-3008 is a series of industrial switches from MOXA China. The Moxa SDS-3008 suffers from a plaintext transmission vulnerability that can be exploited by an attacker to cause the disclosure of sensitive information via specially crafted network sniffing...

7.5CVSS6.2AI score0.00646EPSS
Exploits1References1
CNVD
CNVD
added 2023/02/06 12:0 a.m.8 views

Moxa SDS-3008 Information Disclosure Vulnerability

Moxa SDS-3008 is a series of industrial switches from MOXA China. The Moxa SDS-3008 suffers from an information disclosure vulnerability that can be exploited by an attacker to send specially crafted HTTP requests resulting in the disclosure of sensitive information...

5.3CVSS6.2AI score0.01458EPSS
Exploits1References1
CNVD
CNVD
added 2023/02/06 12:0 a.m.14 views

Moxa SDS-3008 Cross-Site Scripting Vulnerability

Moxa SDS-3008 is a series of industrial switches from MOXA China. The Moxa SDS-3008 suffers from a cross-site scripting vulnerability that can be exploited by an attacker to send a specially crafted HTTP request resulting in arbitrary Javascript execution...

5.4CVSS6.3AI score0.01084EPSS
Exploits1References1
CNNVD
CNNVD
added 2023/02/02 12:0 a.m.5 views

MOXA SDS-3008 跨站脚本漏洞

Moxa SDS-3008 is a series of industrial switches from MOXA China. The Moxa SDS-3008 suffers from a cross-site scripting vulnerability that can be exploited by an attacker to send a specially crafted HTTP request resulting in arbitrary Javascript execution...

5.4CVSS6.4AI score0.01084EPSS
Exploits1References4
BDU FSTEC
BDU FSTEC
added 2022/12/28 12:0 a.m.9 views

The vulnerability of Siemens SCALANCE industrial switches’ microprogramming software, related to buffer overflow in the stack, allows a hacker to execute arbitrary code.

The vulnerability of Siemens SCALANCE industrial switches’ microprogramming software is related to buffer overflow in the stack. Exploiting this vulnerability could allow a remote attacker to execute arbitrary code...

10CVSS8.5AI score0.01539EPSS
Exploits0References4Affected Software2
BDU FSTEC
BDU FSTEC
added 2022/11/11 12:0 a.m.9 views

The vulnerability of Siemens SCALANCE industrial switches’ microprogramming software, related to buffer overflow in the stack, allows a hacker to execute arbitrary code.

The vulnerability of Siemens SCALANCE industrial switches’ microprogramming software is related to buffer overflow in the stack. Exploiting this vulnerability could allow a remote attacker to execute arbitrary code...

10CVSS8.5AI score0.01349EPSS
Exploits0References3Affected Software2
Rows per page