Lucene search
+L

10 matches found

Sick AG
Sick AG
•added 2026/09/04 1:00 p.m.•25 views

Vulnerabilities in Wibu Systems CodeMeter Runtime Affect Multiple SICK Products

Several vulnerabilities in the Wibu Systems CodeMeter Runtime affect the SICK products Sentio Creator, Sentio Compose, Safety Designer, Stream Editor, CODE-LOC, LiDAR-LOC, PLB, SIM1200-2A1A130 LiDAR-LOC and multiple SICK Industrial PCs APU0G00, APU0G50, APU0G03, APU3F00, APU4600, APU8G00 and...

8.6CVSS6AI score0.0046EPSS
SaveExploits0
EUVD
EUVD
•added 2025/10/03 8:07 p.m.•20 views

EUVD-2025-28244

Malicious code in bioql PyPI...

4.3CVSS6.6AI score0.00331EPSS
SaveExploits0References1
BDU FSTEC
BDU FSTEC
•added 2024/11/15 12:00 a.m.•19 views

The vulnerability of the system monitoring application for industrial PCs from Harmony Industrial PC series, namely HMIBMO/HMIBMI/HMIPSO/HMIBMP/HMIBMU/HMIPSP/HMIPEP, arises from the lack of protection for operational data. This allows attackers to expose account information.

The vulnerability of the system monitoring application in Harmony Industrial PCs of the HMIBMO/HMIBMI/HMIPSO/HMIBMP/HMIBMU/HMIPSP/HMIPEP series is related to the lack of protection for operational data. Exploiting this vulnerability can allow a malicious actor to access user accounts remotely...

10CVSS5.4AI score0.00583EPSS
SaveExploits0References3
Tenable Nessus
Tenable Nessus
•added 2022/10/14 12:00 a.m.•41 views

Siemens Devices Using Intel CPUs Improper Privilege Management (CVE-2020-8745)

Insufficient control flow management in subsystem for IntelR CSME versions before 11.8.80, 11.12.80, 11.22.80, 12.0.70, 13.0.40, 13.30.10, 14.0.45 and 14.5.25 , IntelR TXE versions before 3.1.80 and 4.0.30 may allow an unauthenticated user to potentially enable escalation of privilege via physica...

6.8CVSS7AI score0.00383EPSS
SaveExploits0References5
ICS
ICS
•added 2021/05/11 12:00 a.m.•113 views

Siemens Industrial PCs and CNC devices

1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Siemens Equipment: Industrial PCs and CNC devices Vulnerabilities: Improper Input Validation, Improper Authentication, Improper Isolation of Shared Resources on System-on-a-Chip, Improper Privilege Management 2. UPDATE...

7.8CVSS6.4AI score0.00516EPSS
SaveExploits0References11
ICS
ICS
•added 2018/03/01 12:00 a.m.•176 views

ICSA-18-060-01_Siemens SIMATIC, SIMOTION, and SINUMERIK (Update A)

1. EXECUTIVE SUMMARY CVSS v3 8.2 2. UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-18-060-01 Siemens SIMATIC, SIMOTION, and SINUMERIK that was published March 01, 2018, on the NCCIC/ICS-CERT website. 3. RISK EVALUATION Successful exploitation of...

9CVSS8.8AI score0.04407EPSS
SaveExploits0References2
ICS
ICS
•added 2018/02/27 12:00 a.m.•104 views

Siemens SIMATIC Industrial PCs

CVSS v3 5.9 ATTENTION: Remotely exploitable Vendor: Siemens Equipment: SIMATIC Industrial PCs Vulnerability: Cryptographic Issues AFFECTED PRODUCTS Siemens reports that the vulnerability affects the following versions of SIMATIC Industrial PCs using a version of Infineon’s Trusted Platform Module...

5.9CVSS6.6AI score0.09825EPSS
SaveExploits2References36
ICS
ICS
•added 2018/02/22 12:00 a.m.•69 views

Siemens SIMATIC Industrial PCs (Update A)

CVSS v3 5.9 ATTENTION: Exploitable remotely Vendor: Siemens Equipment: SIMATIC Industrial PCs Vulnerability: Cryptographic Issues UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-18-058-01 Siemens SIMATIC Industrial PCs that was published February 27,...

5.9CVSS6.6AI score0.09825EPSS
SaveExploits2References9
ICS
ICS
•added 2017/06/29 12:00 a.m.•109 views

Siemens SIMATIC Industrial PCs, SINUMERIK Panel Control Unit, and SIMOTION P320

CVSS v3 9.8 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Siemens Equipment: SIMATIC Industrial PCs, SINUMERIK Panel Control Unit PCU, SIMOTION P320 Vulnerability: Permissions, Privileges, and Access Controls AFFECTED PRODUCTS Siemens reports that the vulnerability affects...

10CVSS7AI score0.92189EPSS
SaveExploits8References29
ICS
ICS
•added 2017/06/29 12:00 a.m.•120 views

ICSA-17-180-01A_Siemens SIMATIC Industrial PCs, SINUMERIK Panel Control Unit, and SIMOTION P320 (Update A)

CVSS v3 9.8 ATTENTION: Remotely exploitable/low skill level to exploit. Vendor: Siemens Equipment: SIMATIC Industrial PCs, SINUMERIK Panel Control Unit PCU, SIMOTION P320 Vulnerability: Permissions, Privileges, and Access Controls UPDATED INFORMATION This updated advisory is a follow-up to the...

10CVSS7AI score0.92189EPSS
SaveExploits8References2
Rows per page