9 matches found
LSC Smart Connect Indoor IP Camera 安全漏洞
LSC Smart Connect Indoor IP Camera is a camera driver developed by LSC Smart Connect. Version 7.6.32 of the LSC Indoor Camera contains a security vulnerability. This vulnerability stems from the lack of verification of the length of the Protocol parameter within the Transport element. It may lead...
CVE-2024-51347: Buffer Copy without Checking Size of Input
A buffer overflow vulnerability in the dgiot binary in LSC Smart Indoor IP Camera V7.6.32. The flaw exists in the handling of the Time Zone TZ parameter within the ONVIF configuration interface. The time zone TZ parameter does not have its length properly validated before being copied into a...
CVE-2025-65817
LSC Smart Connect Indoor IP Camera 1.4.13 contains a RCE vulnerability in startapp.sh...
CVE-2025-65817
The LSC Smart Connect Indoor IP Camera (version 1.4.13) is vulnerable to Remote Code Execution (RCE) via the start_app.sh script. The root cause is that the script blindly trusts and executes any file named update.nor.sh located on an SD card during the boot process. Specifically, the script copi...
CVE-2025-65817: Improper Control of Generation of Code
LSC Smart Connect Indoor IP Camera 1.4.13 contains a RCE vulnerability in startapp.sh...
PT-2025-52682
Name of the Vulnerable Software and Affected Versions LSC Smart Connect Indoor IP Camera version 1.4.13 Description The LSC Smart Connect Indoor IP Camera version 1.4.13 contains a remote code execution issue in the start app.sh script. Recommendations At the moment, there is no information about...
CVE-2024-51362
The LSC Smart Connect Indoor IP Camera V7.6.32 is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera's feed,...
CVE-2024-51362
The LSC Smart Connect Indoor IP Camera V7.6.32 is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera's feed,...
CVE-2024-51362
The LSC Smart Connect Indoor IP Camera (version V7.6.32 ) is susceptible to an information disclosure vulnerability. The root cause is an unauthenticated RTSP service running on port 8554 , which allows unauthorized users with network access to view live camera footage remotely. This exposure can...