7204 matches found
CVE-2019-20412
The Convert Sub-Task to Issue page in affected versions of Atlassian Jira Server and Data Center allow remote attackers to enumerate the following information via an Improper Authentication vulnerability: Workflow names; Project Key, if it is part of the workflow name; Issue Keys; Issue Types;...
Authentication flaw
The Convert Sub-Task to Issue page in affected versions of Atlassian Jira Server and Data Center allow remote attackers to enumerate the following information via an Improper Authentication vulnerability: Workflow names; Project Key, if it is part of the workflow name; Issue Keys; Issue Types;...
CVE-2019-20412
The CVE-2019-20412 vulnerability affects Atlassian Jira Server/Data Center on Convert Sub-Task to Issue page. Root cause is an Improper Authentication flaw that lets remote attackers enumerate workflow names, the project key (if part of a workflow name), issue keys, issue types, and status types....
CVE-2019-20412: Improper Authentication
The Convert Sub-Task to Issue page in affected versions of Atlassian Jira Server and Data Center allow remote attackers to enumerate the following information via an Improper Authentication vulnerability: Workflow names; Project Key, if it is part of the workflow name; Issue Keys; Issue Types;...
CVE-2019-18252: Improper Authentication
BIOTRONIK CardioMessenger II, The affected products allow credential reuse for multiple authentication purposes. An attacker with adjacent access to the CardioMessenger can disclose its credentials used for connecting to the BIOTRONIK Remote Communication infrastructure...
CVE-2020-12035: Improper Authentication
Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The PrismaFlex device contains a hard-coded service password that provides access to biomedical information, device settings, calibration settings, and network configuration. This could allow an attacker to modify device settings...
CVE-2019-18246: Improper Authentication
BIOTRONIK CardioMessenger II, The affected products do not properly enforce mutual authentication with the BIOTRONIK Remote Communication infrastructure...
CVE-2016-11074: Improper Authentication
An issue was discovered in Mattermost Server before 3.0.0. A password-reset link could be reused...
CVE-2018-21263: Improper Authentication
An issue was discovered in Mattermost Server before 4.7.0, 4.6.2, and 4.5.2. An attacker could authenticate to a different user's account via a crafted SAML response...
CVE-2017-18908: Improper Authentication
An issue was discovered in Mattermost Server before 4.0.0, 3.10.2, and 3.9.2. A password-reset request was sometime sent to an attacker-provided e-mail address...
CVE-2016-11072: Improper Authentication
An issue was discovered in Mattermost Server before 3.0.2. The purposes of a session ID and a Session Token were mishandled...
CVE-2017-18919: Improper Authentication
An issue was discovered in Mattermost Server before 3.7.0 and 3.6.3. Attackers can use the API for unauthenticated team creation...
CVE-2019-20879: Improper Authentication
An issue was discovered in Mattermost Server before 5.8.0, 5.7.2, 5.6.5, and 4.10.7. Changes to e-mail addresses do not require credential re-entry...
CVE-2017-18906: Improper Authentication
An issue was discovered in Mattermost Server before 4.0.0, 3.10.2, and 3.9.2, when Single Sign-On OAuth2 is used. An attacker could claim somebody else's account...
CVE-2020-14455: Improper Authentication
An issue was discovered in Mattermost Desktop App before 4.4.0. Prompting for HTTP Basic Authentication is mishandled, allowing phishing, aka MMSA-2020-0007...
CVE-2019-20875: Improper Authentication
An issue was discovered in Mattermost Server before 5.9.0, 5.8.1, 5.7.3, and 4.10.8. It allows a password reset to proceed while an e-mail address is being changed...
CVE-2020-3361: Improper Authentication
A vulnerability in Cisco Webex Meetings and Cisco Webex Meetings Server could allow an unauthenticated, remote attacker to gain unauthorized access to a vulnerable Webex site. The vulnerability is due to improper handling of authentication tokens by a vulnerable Webex site. An attacker could...
Baxter PrismaFlex and PrisMax (Update B)
1. EXECUTIVE SUMMARY CVSS v3 7.6 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Baxter Equipment: PrismaFlex and PrisMax Vulnerabilities: Cleartext Transmission of Sensitive Information, Improper Authentication, Use of Hard-Coded Password 2. UPDATE INFORMATION This updated...
BIOTRONIK CardioMessenger II
1. EXECUTIVE SUMMARY CVSS v3 4.6 ATTENTION: Exploitable with adjacent access/low skill level to exploit Vendor: BIOTRONIK Equipment: CardioMessenger II-S T-Line, CardioMessenger II-S GSM Vulnerabilities: Improper Authentication, Cleartext Transmission of Sensitive Information, Missing Encryption...
CVE-2020-9076
HUAWEI P30;HUAWEI P30 Pro;Tony-AL00B smartphones with versions earlier than 10.1.0.135C00E135R2P11; versions earlier than 10.1.0.135C00E135R2P8, versions earlier than 10.1.0.135 have an improper authentication vulnerability. Due to the identity of the message sender not being properly verified, a...