Abb Relion Improper Input Validation
ABB Relion 630 devices 1.1 before 1.1.0.C0, 1.2 before 1.2.0.B3, and 1.3 before 1.3.0.A6 allow remote attackers to cause a denial of service reboot via a reboot command in an SPA message. File data ot500307.nasl...
Siemens Simatic Improper Input Validation
Siemens SIMATIC S7-1500 CPU devices before 1.8.3 allow remote attackers to cause a denial of service STOP mode transition via crafted packets on TCP port 102. File data ot500287.nasl...
Siemens Sicam Improper Input Validation
A vulnerability in Siemens SICAM PAS all versions before V8.09 could allow a remote attacker to upload, download, or delete files in certain parts of the file system by sending specially crafted packets to port 19235/TCP. File data ot500098.nasl...
Rockwellautomation Rslinx Improper Input Validation
LogReceiver.exe in Rockwell Automation RSLinx Enterprise CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denial of service service outage via a zero-byte UDP packet that is not properly handled by Logger.dll. File data ot500259.n...
Schneider-electric Somachine Improper Input Validation
A Environment CWE-2 vulnerability exists in SoMachine Basic, all versions, and Modicon M221all references, all versions prior to firmware V1.10.0.0 which could cause remote launch of SoMachine Basic when sending crafted ethernet message. File data ot500329.nasl...
Schneider-electric Modicon Improper Input Validation
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum and Modicon Premium which could cause a possible Denial of Service due to improper data integrity check when sending files the controller over Modbus. File data ot500224.nasl...
Siemens Dnp3 Improper Input Validation
A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module All versions V4.33, Firmware variant PROFINET IO for EN100 Ethernet module All versions, Firmware variant Modbus TCP for EN100 Ethernet module All versions, Firmware variant DNP3 TCP for EN100 Ethernet...
Rockwellautomation Factorytalk Improper Input Validation
An Improper Input Validation issue was discovered in Rockwell Automation FactoryTalk Alarms and Events, Version 2.90 and earlier. An unauthenticated attacker with remote access to a network with FactoryTalk Alarms and Events can send a specially crafted set of packets packet to Port 403/TCP the...
Siemens Sicam Improper Input Validation
Siemens SICAM MIC devices with firmware before 2404 allow remote attackers to bypass authentication and obtain administrative access via unspecified HTTP requests. File data ot500141.nasl...
Siemens Sicam Improper Input Validation
A vulnerability has been identified in SICAM A8000 CP-8000 All versions V14, SICAM A8000 CP-802X All versions V14, SICAM A8000 CP-8050 All versions V2.00. Specially crafted network packets sent to port 80/TCP or 443/TCP could allow an unauthenticated remote attacker to cause a Denial-of-Service...
Medtronic Valleylab FT10 and FX8
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Medtronic Equipment: Valleylab FT10, Valleylab FX8 Vulnerabilities: Use of Hard-coded Credentials, Reversible One-way Hash, Improper Input Validation 2. RISK EVALUATION Successful exploitation of...
Cisco Unified Communications Manager XSS (cisco-sa-20191002-cuc-xss)
According to its self-reported version, Cisco Unified Communications Manager is affected by a cross-site scripting XSS vulnerability. This is due to improper validation of user-supplied input. An unauthenticated, remote attacker can exploit this by convincing a user to click a specially crafted U...
Honeywell equIP Series IP Cameras
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Honeywell Equipment: equIP series IP cameras Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could result in denial-of-service conditions...
Tiki Wiki CMS Groupware cross-site scripting vulnerability (CNVD-2019-39359)
Tiki Wiki CMS Groupware is a Wiki-based open source content management system and online office suite . A cross-site scripting vulnerability exists in Tiki Wiki CMS Groupware version 5.2, which stems from a lack of proper validation of client-side data in the web application and can be exploited ...
PHOENIX CONTACT Automation Worx Software Suite
1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low skill level to exploit Vendor: Phoenix Contact Equipment: Automation Worx Software Suite Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could compromise the availability, integrity, or...
Siemens SIPROTEC 5 < V7.9 and DIGSI 5 < V7.9 Improper Input Validation (ICSA-19-190-05)
Binary data 720310.prm...
ClonOS WEB control panel cross-site scripting vulnerability
ClonOS is an open source platform based on FreeBSD. The platform is mainly used for the creation and management of virtual environments. web control panel is one of the web-based ClonOS control panel. A cross-site scripting vulnerability exists in the index.php file in the ClonOS WEB control pane...
Exploit for Improper Input Validation in Microsoft
cve-2019-0604 SharePoint RCE exploit...
Cisco SPA100 Remote Code Execution Vulnerability (CNVD-2019-36891)
The Cisco SPA100 Series is an analog phone adapter from Cisco that allows your standard analog phone to access Internet telephony services through an RJ-11 phone port. A remote code execution vulnerability exists in the Cisco SPA100 Series with firmware 1.4.1 SR4 and earlier. The vulnerability...
Horner Automation Cscape
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Low skill level to exploit Vendor: Horner Automation Equipment: Cscape Vulnerabilities: Improper Input Validation, Out-of-bounds Write 2. RISK EVALUATION Successful exploitation of these vulnerabilities could crash the device being accessed, which may...