Lucene search
+L

6921 matches found

Veracode
Veracode
added 2020/12/06 4:32 a.m.29 views

Improper Input Validation

zsh is vulnerable to Improper Input Validation. The library does not properly handle the beginning of a ! in script file which may potentially lead to execve call to a program named on the second line...

9.8CVSS2.3AI score0.02487EPSS
SaveExploits0References7Affected Software1
Prion
Prion
added 2020/12/03 12:15 p.m.14 views

Input validation

Improper input validation vulnerability in EC-CUBE versions from 3.0.5 to 3.0.18 allows a remote attacker to cause a denial-of-service DoS condition via unspecified vector...

5CVSS7.4AI score0.01367EPSS
SaveExploits0References2Affected Software1
OSV
OSV
added 2020/11/30 10:15 p.m.5 views

CVE-2020-16850

Mitsubishi MELSEC iQ-R Series PLCs with firmware 49 allow an unauthenticated attacker to halt the industrial process by sending a crafted packet over the network. This denial of service attack exposes Improper Input Validation. After halting, physical access to the PLC is required in order to...

7.5CVSS7.1AI score0.02117EPSS
SaveExploits0References2
NVD
NVD
added 2020/11/30 10:15 p.m.20 views

CVE-2020-16850

Mitsubishi MELSEC iQ-R Series PLCs with firmware 49 allow an unauthenticated attacker to halt the industrial process by sending a crafted packet over the network. This denial of service attack exposes Improper Input Validation. After halting, physical access to the PLC is required in order to...

7.8CVSS7.3AI score0.02117EPSS
SaveExploits0References2
Cvelist
Cvelist
added 2020/11/30 9:34 p.m.25 views

CVE-2020-16850

Mitsubishi MELSEC iQ-R Series PLCs with firmware 49 allow an unauthenticated attacker to halt the industrial process by sending a crafted packet over the network. This denial of service attack exposes Improper Input Validation. After halting, physical access to the PLC is required in order to...

7.3AI score0.02117EPSS
SaveExploits0References2
ICS
ICS
added 2020/11/24 12:0 a.m.68 views

Rockwell Automation FactoryTalk Linx

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/Low skill level to exploit Vendor: Rockwell Automation Equipment: FactoryTalk Linx Vulnerabilities: Improper Input Validation, Heap-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of these vulnerabilities could...

9.8CVSS9AI score0.05461EPSS
SaveExploits0References4
OSV
OSV
added 2020/11/23 5:15 p.m.4 views

CVE-2020-12351

Improper input validation in BlueZ may allow an unauthenticated user to potentially enable escalation of privilege via adjacent access...

8.8CVSS9AI score0.07693EPSS
SaveExploits5References2
CVE
CVE
added 2020/11/23 4:15 p.m.439 views

CVE-2020-12351

CVE-2020-12351 corresponds to the Linux kernel Bluetooth vulnerability known as BleedingTooth. Exploitation involves Bluetooth L2CAP and related memory handling, with PoCs showing remote code execution from a nearby attacker. Root causes cited in public exploit data include a type-confusion error...

8.8CVSS9AI score0.07693EPSS
SaveExploits5References2Affected Software1
Prion
Prion
added 2020/11/20 4:15 p.m.19 views

Input validation

Improper Input validation vulnerability exists in Netis Korea D'live AP which could cause arbitrary command injection and execution when the time setting using ntpServerlp1 parameter for the users. This affects D'live set-top box APWF2429TB v1.1.10...

6CVSS7AI score0.01485EPSS
SaveExploits0References1Affected Software1
NVD
NVD
added 2020/11/17 2:15 p.m.24 views

CVE-2020-7841

Improper input validation vulnerability exists in TOBESOFT XPLATFORM which could cause arbitrary .hta file execution when the command string is begun with http://, https://, mailto://...

8.8CVSS8.9AI score0.01512EPSS
SaveExploits0References1
OSV
OSV
added 2020/11/12 7:15 p.m.4 views

CVE-2020-8669

Improper input validation in the IntelR Data Center Manager Console before version 3.6.2 may allow an authenticated user to potentially enable information disclosure via network access...

6.5CVSS6.6AI score0.00863EPSS
SaveExploits0References1
NVD
NVD
added 2020/11/12 7:15 p.m.21 views

CVE-2020-12349

Improper input validation in the IntelR Data Center Manager Console before version 3.6.2 may allow an authenticated user to potentially enable information disclosure via network access...

6.5CVSS6.2AI score0.00863EPSS
SaveExploits0References1
Cvelist
Cvelist
added 2020/11/12 6:16 p.m.19 views

CVE-2020-12323

Improper input validation in the IntelR ADAS IE before version ADASIE1.0.766 may allow a privileged user to potentially enable escalation of privilege via local access...

6.7AI score0.00318EPSS
SaveExploits0References1
NVD
NVD
added 2020/11/12 6:15 p.m.22 views

CVE-2020-8756

Improper input validation in subsystem for IntelR CSME versions before 11.8.80, 11.12.80, 11.22.80, 12.0.70 and 14.0.45 may allow a privileged user to potentially enable escalation of privilege via local access...

6.7CVSS6.7AI score0.00347EPSS
SaveExploits0References2
Prion
Prion
added 2020/11/12 6:15 p.m.20 views

Input validation

Improper input validation in subsystem for IntelR CSME versions before 11.8.80, 11.12.80, 11.22.80, 12.0.70 and 14.0.45 may allow a privileged user to potentially enable escalation of privilege via local access...

4.6CVSS6.6AI score0.00347EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2020/11/12 6:11 p.m.26 views

CVE-2020-12314

Improper input validation in some IntelR PROSet/Wireless WiFi products before version 21.110 may allow an unauthenticated user to potentially enable denial of service via adjacent access...

6.5AI score0.00455EPSS
SaveExploits0References1
CVE
CVE
added 2020/11/12 12:0 a.m.303 views

CVE-2019-17566

CVE-2019-17566 (Apache Batik) is a server-side request forgery caused by improper input validation in xlink:href attributes, potentially allowing an attacker to trigger arbitrary GET requests from the vulnerable server. Connected advisories reference Batik-related SSRF issues across IBM JRS, SUSE...

7.5CVSS8.2AI score0.1074EPSS
SaveExploits0References10Affected Software1
NVD
NVD
added 2020/11/11 9:15 a.m.21 views

CVE-2020-7328

External entity attack vulnerability in the ePO extension in McAfee MVISION Endpoint prior to 20.11 allows remote attackers to gain control of a resource or trigger arbitrary code execution via improper input validation of an HTTP request, where the content for the attack has been loaded into ePO...

7.2CVSS7.5AI score0.02082EPSS
SaveExploits0References1
CVE
CVE
added 2020/11/11 9:10 a.m.61 views

CVE-2020-7328

Summary (CVE-2020-7328): McAfee MVISION Endpoint’s ePO extension is affected prior to version 20.11. The issue is a server-side input validation flaw that permits a remote attacker to load attack content into ePO and potentially gain control of a resource or trigger arbitrary code execution via H...

7.2CVSS7.6AI score0.02082EPSS
SaveExploits0References1Affected Software1
Tenable Nessus
Tenable Nessus
added 2020/11/11 12:0 a.m.36 views

Amazon Linux 2 : libvpx (ALAS-2020-1558)

The version of libvpx installed on the remote host is prior to 1.3.0-8. It is, therefore, affected by multiple vulnerabilities as referenced in the ALAS2-2020-1558 advisory. A denial of service vulnerability in libvpx in Mediaserver could enable a remote attacker to use a specially crafted file t...

7.8CVSS6.5AI score0.05092EPSS
SaveExploits0References9
Rows per page