Lucene search
+L

2379 matches found

Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/03/15 12:00 a.m.•4 views

CVE-2018-6219: Improper Certificate Validation

An Insecure Update via HTTP vulnerability in Trend Micro Email Encryption Gateway 5.5 could allow an attacker to eavesdrop and tamper with certain types of update data...

6.5CVSS6.9AI score0.03881EPSS
SaveExploits5References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/03/15 12:00 a.m.•3 views

CVE-2018-6221: Improper Certificate Validation

An unvalidated software update vulnerability in Trend Micro Email Encryption Gateway 5.5 could allow a man-in-the-middle attacker to tamper with an update file and inject their own...

9.3CVSS7.6AI score0.06095EPSS
SaveExploits5References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/03/12 12:00 a.m.•7 views

CVE-2017-18227: Improper Certificate Validation

TitanHQ WebTitan Gateway has incorrect certificate validation for the TLS interception feature...

7.5CVSS7.2AI score0.00696EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/03/12 12:00 a.m.•4 views

CVE-2016-9952: Improper Certificate Validation

The verifycertificate function in lib/vtls/schannel.c in libcurl 7.30.0 through 7.51.0, when built for Windows CE using the schannel TLS backend, makes it easier for remote attackers to conduct man-in-the-middle attacks via a crafted wildcard SAN in a server certificate, as demonstrated by ".com....

8.1CVSS7.6AI score0.01276EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/03/09 12:00 a.m.•4 views

CVE-2018-7234: Improper Certificate Validation

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow arbitrary system file download due to lack of validation of SSL certificate...

7.8CVSS7.3AI score0.00956EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/02/23 12:00 a.m.•6 views

CVE-2018-0518: Improper Certificate Validation

LINE for iOS version 7.1.3 to 7.1.5 does not verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spoof servers and obtain sensitive information via a crafted certificate...

5.9CVSS6.2AI score0.00592EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/02/20 12:00 a.m.•6 views

CVE-2017-17455: Improper Certificate Validation

Mahara 16.10 before 16.10.7, 17.04 before 17.04.5, and 17.10 before 17.10.2 are vulnerable to being forced, via a man-in-the-middle attack, to interact with Mahara on the HTTP protocol rather than HTTPS even when an SSL certificate is present...

5.9CVSS6.2AI score0.00605EPSS
SaveExploits0References2
Prion
Prion
•added 2018/02/15 10:29 a.m.•23 views

Input validation

An Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump does not validate host certificates, leaving the pump vulnerable to a man-in-the-middle MITM attack...

4.3CVSS6.3AI score0.00673EPSS
SaveExploits0References2Affected Software1
OSV
OSV
•added 2018/02/15 10:29 a.m.•14 views

CVE-2017-12721

An Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump does not validate host certificates, leaving the pump vulnerable to a man-in-the-middle MITM attack...

5.9CVSS5.8AI score0.00673EPSS
SaveExploits0References2
NVD
NVD
•added 2018/02/15 10:29 a.m.•36 views

CVE-2017-12721

An Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump does not validate host certificates, leaving the pump vulnerable to a man-in-the-middle MITM attack...

5.9CVSS6.4AI score0.00673EPSS
SaveExploits0References2
CVE
CVE
•added 2018/02/15 10:00 a.m.•72 views

CVE-2017-12721

This CVE concerns the Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump and its failure to validate host certificates, enabling potential MITM attacks. Affected firmware versions are 1.1, 1.5, and 1.6. The underlying issue is Improper Certificate Validation, which can allow remote atta...

5.9CVSS5.6AI score0.00673EPSS
SaveExploits0References2Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/02/15 12:00 a.m.•9 views

CVE-2017-15341: Improper Certificate Validation

Huawei AR3200 V200R008C20, V200R008C30, TE40 V600R006C00, TE50 V600R006C00, TE60 V600R006C00 have a denial of service vulnerability. The software decodes X.509 certificate in an improper way. A remote unauthenticated attacker could send a crafted X.509 certificate to the device. Successful exploi...

7.5CVSS7.2AI score0.00759EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/02/15 12:00 a.m.•8 views

CVE-2017-12721: Improper Certificate Validation

An Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump does not validate host certificates, leaving the pump vulnerable to a man-in-the-middle MITM attack...

5.9CVSS6.3AI score0.00673EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/02/15 12:00 a.m.•6 views

CVE-2017-17301: Improper Certificate Validation

Huawei AR120-S V200R005C32, V200R006C10, V200R007C00, V200R008C20, AR1200 V200R005C20, V200R005C32, V200R006C10, V200R007C00, V200R007C01, V200R007C02, V200R008C20, AR1200-S V200R005C32, V200R006C10, V200R007C00, V200R008C20, AR150 V200R006C10, V200R007C00, V200R007C01, V200R007C02, V200R008C20,...

9.8CVSS8.2AI score0.00972EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2018/02/15 12:00 a.m.•3 views

PT-2018-5449

Name of the Vulnerable Software and Affected Versions: Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump versions 1.1, 1.5, and 1.6 Description: An issue with improper certificate validation was found, which could allow a man-in-the-middle MITM attack. The pump fails to validate host...

5.9CVSS0.00673EPSS
SaveExploits0References4
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/02/12 12:00 a.m.•9 views

CVE-2017-9968: Improper Certificate Validation

A security misconfiguration vulnerability exists in Schneider Electric's IGSS Mobile application versions 3.01 and prior in which a lack of certificate pinning during the TLS/SSL connection establishing process can result in a man-in-the-middle attack...

5.9CVSS6.4AI score0.01151EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/02/09 12:00 a.m.•7 views

CVE-2018-6827: Improper Certificate Validation

VOBOT CLOCK before 0.99.30 devices do not verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spoof servers and obtain sensitive information, and consequently execute arbitrary code, via a crafted certificate, as demonstrated by leveraging a hardcoded...

8.1CVSS7.8AI score0.00912EPSS
SaveExploits1References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/01/31 12:00 a.m.•5 views

CVE-2017-15698: Improper Certificate Validation

When parsing the AIA-Extension field of a client certificate, Apache Tomcat Native Connector 1.2.0 to 1.2.14 and 1.1.23 to 1.1.34 did not correctly handle fields longer than 127 bytes. The result of the parsing error was to skip the OCSP check. It was therefore possible for client certificates th...

5.9CVSS6.4AI score0.03527EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/01/31 12:00 a.m.•5 views

CVE-2018-6374: Improper Certificate Validation

The GUI component aka PulseUI in Pulse Secure Desktop Linux clients before PULSE5.2R9.2 and 5.3.x before PULSE5.3R4.2 does not perform strict SSL Certificate Validation. This can lead to the manipulation of the Pulse Connection set...

6.5CVSS6.5AI score0.00616EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2018/01/26 12:00 a.m.•7 views

CVE-2017-1000396: Improper Certificate Validation

Jenkins 2.73.1 and earlier, 2.83 and earlier bundled a version of the commons-httpclient library with the vulnerability CVE-2012-6153 that incorrectly verified SSL certificates, making it susceptible to man-in-the-middle attacks. This library is widely used as a transitive dependency in Jenkins...

5.9CVSS6.7AI score0.00497EPSS
SaveExploits0References2
Rows per page
Query Builder