2379 matches found
CVE-2018-6219: Improper Certificate Validation
An Insecure Update via HTTP vulnerability in Trend Micro Email Encryption Gateway 5.5 could allow an attacker to eavesdrop and tamper with certain types of update data...
CVE-2018-6221: Improper Certificate Validation
An unvalidated software update vulnerability in Trend Micro Email Encryption Gateway 5.5 could allow a man-in-the-middle attacker to tamper with an update file and inject their own...
CVE-2017-18227: Improper Certificate Validation
TitanHQ WebTitan Gateway has incorrect certificate validation for the TLS interception feature...
CVE-2016-9952: Improper Certificate Validation
The verifycertificate function in lib/vtls/schannel.c in libcurl 7.30.0 through 7.51.0, when built for Windows CE using the schannel TLS backend, makes it easier for remote attackers to conduct man-in-the-middle attacks via a crafted wildcard SAN in a server certificate, as demonstrated by ".com....
CVE-2018-7234: Improper Certificate Validation
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow arbitrary system file download due to lack of validation of SSL certificate...
CVE-2018-0518: Improper Certificate Validation
LINE for iOS version 7.1.3 to 7.1.5 does not verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spoof servers and obtain sensitive information via a crafted certificate...
CVE-2017-17455: Improper Certificate Validation
Mahara 16.10 before 16.10.7, 17.04 before 17.04.5, and 17.10 before 17.10.2 are vulnerable to being forced, via a man-in-the-middle attack, to interact with Mahara on the HTTP protocol rather than HTTPS even when an SSL certificate is present...
Input validation
An Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump does not validate host certificates, leaving the pump vulnerable to a man-in-the-middle MITM attack...
CVE-2017-12721
An Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump does not validate host certificates, leaving the pump vulnerable to a man-in-the-middle MITM attack...
CVE-2017-12721
An Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump does not validate host certificates, leaving the pump vulnerable to a man-in-the-middle MITM attack...
CVE-2017-12721
This CVE concerns the Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump and its failure to validate host certificates, enabling potential MITM attacks. Affected firmware versions are 1.1, 1.5, and 1.6. The underlying issue is Improper Certificate Validation, which can allow remote atta...
CVE-2017-15341: Improper Certificate Validation
Huawei AR3200 V200R008C20, V200R008C30, TE40 V600R006C00, TE50 V600R006C00, TE60 V600R006C00 have a denial of service vulnerability. The software decodes X.509 certificate in an improper way. A remote unauthenticated attacker could send a crafted X.509 certificate to the device. Successful exploi...
CVE-2017-12721: Improper Certificate Validation
An Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump does not validate host certificates, leaving the pump vulnerable to a man-in-the-middle MITM attack...
CVE-2017-17301: Improper Certificate Validation
Huawei AR120-S V200R005C32, V200R006C10, V200R007C00, V200R008C20, AR1200 V200R005C20, V200R005C32, V200R006C10, V200R007C00, V200R007C01, V200R007C02, V200R008C20, AR1200-S V200R005C32, V200R006C10, V200R007C00, V200R008C20, AR150 V200R006C10, V200R007C00, V200R007C01, V200R007C02, V200R008C20,...
PT-2018-5449
Name of the Vulnerable Software and Affected Versions: Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump versions 1.1, 1.5, and 1.6 Description: An issue with improper certificate validation was found, which could allow a man-in-the-middle MITM attack. The pump fails to validate host...
CVE-2017-9968: Improper Certificate Validation
A security misconfiguration vulnerability exists in Schneider Electric's IGSS Mobile application versions 3.01 and prior in which a lack of certificate pinning during the TLS/SSL connection establishing process can result in a man-in-the-middle attack...
CVE-2018-6827: Improper Certificate Validation
VOBOT CLOCK before 0.99.30 devices do not verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spoof servers and obtain sensitive information, and consequently execute arbitrary code, via a crafted certificate, as demonstrated by leveraging a hardcoded...
CVE-2017-15698: Improper Certificate Validation
When parsing the AIA-Extension field of a client certificate, Apache Tomcat Native Connector 1.2.0 to 1.2.14 and 1.1.23 to 1.1.34 did not correctly handle fields longer than 127 bytes. The result of the parsing error was to skip the OCSP check. It was therefore possible for client certificates th...
CVE-2018-6374: Improper Certificate Validation
The GUI component aka PulseUI in Pulse Secure Desktop Linux clients before PULSE5.2R9.2 and 5.3.x before PULSE5.3R4.2 does not perform strict SSL Certificate Validation. This can lead to the manipulation of the Pulse Connection set...
CVE-2017-1000396: Improper Certificate Validation
Jenkins 2.73.1 and earlier, 2.83 and earlier bundled a version of the commons-httpclient library with the vulnerability CVE-2012-6153 that incorrectly verified SSL certificates, making it susceptible to man-in-the-middle attacks. This library is widely used as a transitive dependency in Jenkins...