B&R Industrial Automation GmbH Runtime 安全漏洞
B&R Industrial Automation GmbH Runtime is a major component of the AS from B&R Industrial Automation, Austria. A security vulnerability exists in B&R Industrial Automation GmbH Runtime versions prior to G4.93, which stems from an improper initialization issue that results in multiple services bei...
CVE-2023-37479: Improper Initialization
Open Enclave is a hardware-agnostic open source library for developing applications that utilize Hardware-based Trusted Execution Environments, also known as Enclaves. There are two issues that are mitigated in version 0.19.3. First, Open Enclave SDK does not properly sanitize the MXCSR register ...
Exploit for Improper Initialization in Linux Linux_Kernel
CVE-2022-0847-Exploit-Implementation This is a POC showing ho...
CVE-2022-48518: Improper Initialization
Vulnerability of signature verification in the iaware system being initialized later than the time when the system broadcasts are sent. Successful exploitation of this vulnerability may cause malicious apps to start upon power-on by spoofing the package names of apps in the startup trustlist, whi...
Mitsubishi Electric MELSEC-F Series Improper Initialization (CVE-2021-20613)
Improper initialization vulnerability in MELSEC-F series FX3U-ENET Firmware version 1.16 and prior, FX3U-ENET-L Firmware version 1.16 and prior and FX3U-ENET-P502 Firmware version 1.16 and prior allows a remote unauthenticated attacker to cause a denial-of-service DoS condition in communication...
Divide By Zero
qt6-qtsvg is vulnerable to Divide By Zero. The vulnerability due to the improper initialization of the QSvgFont munitsPerEm, which allows an attacker to cause an application crash...
Input validation
Improper initialization for some IntelR NUC BIOS firmware may allow a privileged user to potentially enable information disclosure via local access...
PT-2023-13044 · Intel · Intel Nuc Bios
Name of the Vulnerable Software and Affected Versions: IntelR NUC BIOS firmware affected versions not specified Description: The issue is related to improper initialization in some IntelR NUC BIOS firmware, which may allow a privileged user to potentially enable information disclosure via local...
CVE-2023-27934: Improper Initialization
A memory initialization issue was addressed. This issue is fixed in macOS Ventura 13.3, macOS Monterey 12.6.4. A remote attacker may be able to cause unexpected app termination or arbitrary code execution...
Exploit for Improper Initialization in Linux Linux_Kernel
CVE-2022-0847 A simple exploit that uses dirtypipe to inject s...
The vulnerability of the software and hardware components of SCADA systems such as ABB Relion 611, Relion 615, Relion 620, Relion REF615, Relion RED615, Relion RER620, Relion RER615, Relion REX640, eVD4, REC615, and SMU615 lies in improper initialization of resources, which allows attackers to trigger maintenance-related failures.
The vulnerability of the software and hardware components of SCADA systems such as ABB Relion 611, Relion 615, Relion 620, Relion REF615, Relion RED615, Relion RER620, Relion RER615, Relion REX640, eVD4, REC615, and SMU615 is related to improper initialization of resources. Exploiting this...
CVE-2023-26084: Improper Initialization
The armv8decaesgcmfull API of Arm AArch64cryptolib before 86065c6 fails to the verify the authentication tag of AES-GCM protected data, leading to a man-in-the-middle attack. This occurs because of an improperly initialized variable...
ABB SMU615 Improper Initialization (CVE-2021-22283)
Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion protection relays - 615 series IEC 4.0 FP1, ABB Relion protection relays - 615 series CN 4.0 FP1, ABB Relion protection relays - 615 series IEC 5.0, ABB Relion protection relays - 615 series IEC 5.0 FP1...
PT-2023-36771
Уязвимость функции mptcp close ssk и mptcp worker модуля net/mptcp/protocol.c ядра операционной системы Linux связана с некорректной инициализацией. Эксплуатация уязвимости может позволить нарушителю оказать воздействие на конфиденциальность, целостность и доступность защищаемой информации...
Parallels Desktop Updater Improper Initialization Local Privilege Escalation Vulnerability
This vulnerability allows local attackers to escalate privileges on affected installations of Parallels Desktop. An attacker must first obtain the ability to execute low-privileged code on the target host system in order to exploit this vulnerability. The specific flaw exists within the Updater...
CVE-2021-22283
Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion protection relays - 615 series IEC 4.0 FP1, ABB Relion protection relays - 615 series CN 4.0 FP1, ABB Relion protection relays - 615 series IEC 5.0, ABB Relion protection relays - 615 series IEC 5.0 FP1...
Input validation
Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion protection relays - 615 series IEC 4.0 FP1, ABB Relion protection relays - 615 series CN 4.0 FP1, ABB Relion protection relays - 615 series IEC 5.0, ABB Relion protection relays - 615 series IEC 5.0 FP1...
CVE-2021-22283 MMS File Transfer Vulnerability impact on Distribution Automation products
Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion protection relays - 615 series IEC 4.0 FP1, ABB Relion protection relays - 615 series CN 4.0 FP1, ABB Relion protection relays - 615 series IEC 5.0, ABB Relion protection relays - 615 series IEC 5.0 FP1...
CVE-2021-22283 MMS File Transfer Vulnerability impact on Distribution Automation products
Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion protection relays - 615 series IEC 4.0 FP1, ABB Relion protection relays - 615 series CN 4.0 FP1, ABB Relion protection relays - 615 series IEC 5.0, ABB Relion protection relays - 615 series IEC 5.0 FP1...
CVE-2021-22283: Improper Initialization
Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion protection relays - 615 series IEC 4.0 FP1, ABB Relion protection relays - 615 series CN 4.0 FP1, ABB Relion protection relays - 615 series IEC 5.0, ABB Relion protection relays - 615 series IEC 5.0 FP1...