Lucene search
+L

29 matches found

OSV
OSV
added 2020/07/14 6:15 p.m.27 views

CVE-2020-13845

Sylabs Singularity 3.0 through 3.5 has Improper Validation of an Integrity Check Value. Image integrity is not validated when an ECL policy is enforced. The fingerprint required by the ECL is compared against the signature object descriptors in the SIF file, rather than to a cryptographically...

7.5CVSS6.6AI score
SaveExploits0References5
OSV
OSV
added 2020/07/14 6:15 p.m.7 views

UBUNTU-CVE-2020-13845

Sylabs Singularity 3.0 through 3.5 has Improper Validation of an Integrity Check Value. Image integrity is not validated when an ECL policy is enforced. The fingerprint required by the ECL is compared against the signature object descriptors in the SIF file, rather than to a cryptographically...

7.5CVSS7.1AI score0.00517EPSS
SaveExploits0References4
CVE
CVE
added 2020/07/14 5:23 p.m.164 views

CVE-2020-13845

CVE-2020-13845 affects Sylabs Singularity 3.0–3.5. The vulnerability is improper validation of an integrity check value: image integrity is not validated when an ECL policy is enforced, because the fingerprint is compared against the SIF descriptor instead of a cryptographically validated signatu...

7.5CVSS7.4AI score0.00517EPSS
SaveExploits0References5Affected Software1
Cvelist
Cvelist
added 2020/07/14 5:23 p.m.37 views

CVE-2020-13845

Sylabs Singularity 3.0 through 3.5 has Improper Validation of an Integrity Check Value. Image integrity is not validated when an ECL policy is enforced. The fingerprint required by the ECL is compared against the signature object descriptors in the SIF file, rather than to a cryptographically...

7.5AI score0.00517EPSS
SaveExploits0References5
Debian CVE
Debian CVE
added 2020/07/14 5:23 p.m.78 views

CVE-2020-13845

Removed by vendor...

7.5CVSS7.1AI score0.00517EPSS
SaveExploits0
ICS
ICS
added 2019/08/29 12:00 a.m.76 views

Philips HDI 4000 Ultrasound

1. EXECUTIVE SUMMARY CVSS v3 3.0 ATTENTION: Public exploits are available/exploitable from within the same local subnet Vendor: Philips Equipment: HDI 4000 Ultrasound Systems Vulnerability: Use of Obsolete Function 2. RISK EVALUATION Successful exploitation of this vulnerability could lead to...

3.6CVSS4.1AI score0.00344EPSS
SaveExploits0References5
Positive Technologies
Positive Technologies
added 2019/05/17 12:00 a.m.6 views

PT-2019-3149 · Fortinet · Fortimanager

Name of the Vulnerable Software and Affected Versions: FortiManager VM versions 6.2.0, 6.0.6 and below Description: The issue is due to insufficient input validation in the FortiManager VM application. This could allow a remote attacker to execute arbitrary code or commands. Additionally, the lac...

10CVSS9.5AI score0.0077EPSS
SaveExploits0References4
Positive Technologies
Positive Technologies
added 2016/04/13 12:00 a.m.9 views

PT-2016-4404

Name of the Vulnerable Software and Affected Versions OpenStack Image Service Glance versions prior to 2015.1.3 kilo OpenStack Image Service Glance versions 11.0.x prior to 11.0.2 liberty Description The issue allows remote authenticated users to tamper with images, potentially compromising the...

4.3CVSS6AI score0.01466EPSS
SaveExploits0References34
securityvulns
securityvulns
added 2015/01/25 12:00 a.m.74 views

AVM FRITZ!Box protection bypass

Image integrity protection bypass...

9.3CVSS2.6AI score0.01503EPSS
SaveExploits3References1
Rows per page
Query Builder