540 matches found
Schneider Electric IGSS SCADA Software Local Code Execution Vulnerability
Schneider Electric IGSS SCADA Software is a shared service platform for SCADA Data Acquisition and Supervisory Control systems from Schneider Electric France. A security vulnerability exists in Schneider Electric IGSS SCADA Software version 12 and earlier, which stems from incorrect security...
Schneider Electric IGSS Mobile
CVSS v3 6.4 ATTENTION: Locally exploitable/low skill level to exploit. Vendor: Schneider Electric Equipment: IGSS Mobile Vulnerabilities: Improper Certificate Validation, Plaintext Storage of a Password AFFECTED PRODUCTS Schneider Electric reports that the vulnerabilities affect the following IGS...
Schneider Electric IGSS SCADA Software
CVSS v3 7.0 ATTENTION: Locally exploitable/high skill level to exploit. Vendor: Schneider Electric Equipment: IGSS SCADA Software Vulnerability: Security Misconfiguration AFFECTED PRODUCTS Schneider Electric reports that the vulnerability affects the following IGSS SCADA Software products: IGSS...
Schneider Electric IGSS Mobile Information Disclosure Vulnerability
Schneider Electric IGSS Mobile is a suite of mobile applications for managing IGSS Shared Services Platform from Schneider Electric, France. An information disclosure vulnerability exists in Schneider Electric IGSS Mobile version 3.01 and prior versions, which stems from the program storing...
CVE-2017-9967
A security misconfiguration vulnerability exists in Schneider Electric's IGSS SCADA Software versions 12 and prior. Security configuration settings such as Address Space Layout Randomization ASLR and Data Execution prevention DEP were not properly configured resulting in weak security...
CVE-2017-9969
An information disclosure vulnerability exists in Schneider Electric's IGSS Mobile application version 3.01 and prior. Passwords are stored in clear text in the configuration which can result in exposure of sensitive information...
CVE-2017-9968
A security misconfiguration vulnerability exists in Schneider Electric's IGSS Mobile application versions 3.01 and prior in which a lack of certificate pinning during the TLS/SSL connection establishing process can result in a man-in-the-middle attack...
CVE-2017-9968
A security misconfiguration vulnerability exists in Schneider Electric's IGSS Mobile application versions 3.01 and prior in which a lack of certificate pinning during the TLS/SSL connection establishing process can result in a man-in-the-middle attack...
Security feature bypass
A security misconfiguration vulnerability exists in Schneider Electric's IGSS Mobile application versions 3.01 and prior in which a lack of certificate pinning during the TLS/SSL connection establishing process can result in a man-in-the-middle attack...
CVE-2017-9969
An information disclosure vulnerability exists in Schneider Electric's IGSS Mobile application version 3.01 and prior. Passwords are stored in clear text in the configuration which can result in exposure of sensitive information...
CVE-2017-9967
A security misconfiguration vulnerability exists in Schneider Electric's IGSS SCADA Software versions 12 and prior. Security configuration settings such as Address Space Layout Randomization ASLR and Data Execution prevention DEP were not properly configured resulting in weak security...
Security feature bypass
A security misconfiguration vulnerability exists in Schneider Electric's IGSS SCADA Software versions 12 and prior. Security configuration settings such as Address Space Layout Randomization ASLR and Data Execution prevention DEP were not properly configured resulting in weak security...
Information disclosure
An information disclosure vulnerability exists in Schneider Electric's IGSS Mobile application version 3.01 and prior. Passwords are stored in clear text in the configuration which can result in exposure of sensitive information...
CVE-2017-9969
The CVE-2017-9969 entry affects Schneider Electric IGSS Mobile (Android/iOS) up to version 3.01 and earlier. The root cause is plaintext storage of passwords in the app configuration, enabling exposure of sensitive credentials and potential information disclosure. The ICSA advisory notes CVSS v3 ...
CVE-2017-9968
IGSS Mobile (Schneider Electric) affected: Android and iOS apps version 3.01 and earlier. Root cause: missing certificate pinning during TLS/SSL handshake, enabling potential MITM risks. Public-facing impact: credential exposure risk and MITM possibility as described in ICSA-18-046-03; CVSS v3 ba...
CVE-2017-9967
Affected product: Schneider Electric IGSS SCADA Software (version 12 and earlier). Root cause: security misconfiguration of memory protection (ASLR and DEP) leading to weak security. Impact: vulnerability described as a local, likely code-execution risk when exploiting improper security configura...
CVE-2017-9967
A security misconfiguration vulnerability exists in Schneider Electric's IGSS SCADA Software versions 12 and prior. Security configuration settings such as Address Space Layout Randomization ASLR and Data Execution prevention DEP were not properly configured resulting in weak security...
CVE-2017-9968
A security misconfiguration vulnerability exists in Schneider Electric's IGSS Mobile application versions 3.01 and prior in which a lack of certificate pinning during the TLS/SSL connection establishing process can result in a man-in-the-middle attack...
CVE-2017-9969
An information disclosure vulnerability exists in Schneider Electric's IGSS Mobile application version 3.01 and prior. Passwords are stored in clear text in the configuration which can result in exposure of sensitive information...
CVE-2017-6033
A DLL Hijacking issue was discovered in Schneider Electric Interactive Graphical SCADA System IGSS Software, Version 12 and previous versions. The software will execute a malicious file if it is named the same as a legitimate file and placed in a location that is earlier in the search path...