Lucene search
+L

560 matches found

Positive Technologies
Positive Technologies
added 2022/06/14 12:00 a.m.78 views

PT-2022-3201 · Unknown · Igss Data Server

Name of the Vulnerable Software and Affected Versions: IGSS Data Server - IGSSdataServer.exe versions prior to V15.0.0.22170 Description: A buffer copy without checking the size of input vulnerability exists, potentially leading to a stack-based buffer overflow and remote code execution when an...

10CVSS9.8AI score0.01269EPSS
SaveExploits0References7
Positive Technologies
Positive Technologies
added 2022/06/14 12:00 a.m.10 views

PT-2022-3197 · Unknown · Igss Data Server

Name of the Vulnerable Software and Affected Versions: IGSS Data Server versions prior to V15.0.0.22170 Description: The issue is related to a buffer copy without checking the size of input data, which could cause a stack-based buffer overflow. This might lead to remote code execution when an...

9.8CVSS9.7AI score0.01269EPSS
SaveExploits0References7
CNVD
CNVD
added 2022/04/24 12:00 a.m.23 views

A binary vulnerability exists in IGSS (Interactive Graphical SCADA System)

IGSS Interactive Graphical SCADA System is an industrial control SCADA system from Schneider, which is used in various fields such as power, wastewater treatment, manufacturing, etc. A binary vulnerability exists in IGSS Interactive Graphical SCADA System, which can be exploited by attackers to...

3.5AI score
SaveExploits0
Positive Technologies
Positive Technologies
added 2022/04/12 12:00 a.m.11 views

PT-2022-3142 · Unknown · Igss Data Server

Name of the Vulnerable Software and Affected Versions: IGSS Data Server - IGSSdataServer.exe versions prior to V15.0.0.22073 Description: A buffer copy without checking the size of the input issue exists, potentially leading to a stack-based buffer overflow and remote code execution when an...

9.8CVSS10AI score0.01204EPSS
SaveExploits0References8
Positive Technologies
Positive Technologies
added 2022/04/12 12:00 a.m.16 views

PT-2022-3589 · Unknown · Igss Data Server

Name of the Vulnerable Software and Affected Versions: IGSS Data Server - IGSSdataServer.exe versions prior to V15.0.0.22073 Description: A CWE-190: Integer Overflow or Wraparound issue exists, potentially causing a heap-based buffer overflow. This could lead to denial of service and possibly...

10CVSS9.8AI score0.02141EPSS
SaveExploits0References5
Tenable Nessus
Tenable Nessus
added 2022/03/17 12:00 a.m.108 views

Schneider Electric IGSS Data Server Path Traversal (CVE-2022-24312)

Binary data schneiderelectricigsscve-2022-24312.nbin...

9.8CVSS9.6AI score0.03463EPSS
SaveExploits0References3
CNVD
CNVD
added 2022/02/18 12:00 a.m.56 views

Schneider Electric Interactive Graphical Scada System Integer Overflow Vulnerability

The Schneider Electric Interactive Graphical Scada System Igss is a Scada system for monitoring and controlling industrial processes from Schneider Electric, France. The Schneider Electric Interactive Graphical Scada System has an integer overflow vulnerability that can be exploited by an attacke...

9.8CVSS9.7AI score0.02227EPSS
SaveExploits0References1
ICS
ICS
added 2022/02/15 12:00 a.m.103 views

Schneider Electric IGSS

1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: IGSS Interactive Graphical SCADA System Vulnerabilities: Integer Overflow or Wraparound, Path Traversal, Classic Buffer Overflow, Out-of-bounds Read, Improper...

9.8CVSS9.7AI score0.44559EPSS
SaveExploits0References4
CNVD
CNVD
added 2022/02/15 12:00 a.m.53 views

Schneider Electric Interactive Graphical SCADA System Access Control Error Vulnerability (CNVD-2022-13067)

Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. An access control error vulnerability exists in the Schneider Electric Interactive Graphical...

9.1CVSS9.2AI score0.21388EPSS
SaveExploits0References1
CNVD
CNVD
added 2022/02/13 12:00 a.m.61 views

Schneider Electric Interactive Graphical SCADA System Out-of-Bounds Read Vulnerability

Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. An out-of-bounds read vulnerability exists in the Schneider Electric Interactive Graphical SCAD...

7.5CVSS7.3AI score0.19255EPSS
SaveExploits0References1
CNVD
CNVD
added 2022/02/13 12:00 a.m.51 views

Schneider Electric Interactive Graphical SCADA System Authorization Issues Vulnerability

Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. An authorization issue vulnerability exists in the Schneider Electric Interactive Graphical SCA...

7.5CVSS7.6AI score0.01206EPSS
SaveExploits0References1
ATTACKERKB
ATTACKERKB
added 2022/02/11 6:15 p.m.7 views

CVE-2021-22804

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause disclosure of arbitrary files being read in the context of the user running IGSS, due to missing validation of user supplied data in network messages. Affected Product: Interactive Graphica...

7.5CVSS7.1AI score0.01294EPSS
SaveExploits0References2
NVD
NVD
added 2022/02/11 6:15 p.m.23 views

CVE-2021-22823

A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector dc.exe V15.0.0.21320...

9.1CVSS0.21388EPSS
SaveExploits0References1
NVD
NVD
added 2022/02/11 6:15 p.m.31 views

CVE-2021-22805

A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector dc.exe V15.0.0.21243...

9.1CVSS0.0085EPSS
SaveExploits0References1
NVD
NVD
added 2022/02/11 6:15 p.m.25 views

CVE-2021-22804

A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause disclosure of arbitrary files being read in the context of the user running IGSS, due to missing validation of user supplied data in network messages. Affected Product: Interactive Graphica...

7.5CVSS0.01294EPSS
SaveExploits0References1
ATTACKERKB
ATTACKERKB
added 2022/02/11 6:15 p.m.7 views

CVE-2021-22805

A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector dc.exe V15.0.0.21243...

9.1CVSS6.8AI score0.0085EPSS
SaveExploits0References2
Prion
Prion
added 2022/02/11 6:15 p.m.19 views

Authentication flaw

A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector dc.exe V15.0.0.21320...

5CVSS9.1AI score0.21388EPSS
SaveExploits0References1Affected Software1
CVE
CVE
added 2022/02/11 5:40 p.m.68 views

CVE-2021-22823

CVE-2021-22823 affects Schneider Electric IGSS Interactive Graphical SCADA System Data Collector (dc.exe) on v15.0.0.21320 and earlier. It is a CWE-306 Missing Authentication for Critical Function vulnerability caused by lack of validation of network messages, which could lead to deletion of arbi...

9.1CVSS9.1AI score0.21388EPSS
SaveExploits0References1Affected Software1
Cvelist
Cvelist
added 2022/02/11 5:40 p.m.29 views

CVE-2021-22823

A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector dc.exe V15.0.0.21320...

9.3AI score0.21388EPSS
SaveExploits0References1
CVE
CVE
added 2022/02/11 5:40 p.m.83 views

CVE-2021-22805

Schneider Electric IGSS DC (dc.exe) up to v15.0.0.21243 is affected by CVE-2021-22805 (CWE-306) due to missing authentication for a critical function caused by lack of validation of network messages. This could allow a remote attacker to delete arbitrary files in the context of the running user. ...

9.1CVSS9.1AI score0.0085EPSS
SaveExploits0References1Affected Software1
Rows per page
Query Builder