ICS
ICS
•added 2026/10/01 6:00 a.m.•31 views

ABB Protection and Control IED Manager PCM600

ADVISORY SUMMARY Successful exploitation of these vulnerabilities could allow an attacker to escalate privileges or overwrite files. 2. RECOMMENDED PRACTICES CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for...

5.9AI score
SaveExploits0References13
NVD
NVD
•added 2026/09/28 2:17 p.m.•13 views

CVE-2026-15953

Improper Limitation of a Pathname to a Restricted Directory 'Path Traversal' vulnerability in ABB Protection and control IED manager PCM600. This issue affects Protection and control IED manager PCM600: through 2.14...

5.6CVSS0.00115EPSS
SaveExploits0References1
NVD
NVD
•added 2026/09/28 2:17 p.m.•13 views

CVE-2026-15952

Incorrect Permission Assignment for Critical Resource vulnerability in ABB Protection and control IED manager PCM600. This issue affects Protection and control IED manager PCM600: through 2.14...

7.1CVSS0.00092EPSS
SaveExploits0References1
CVE
CVE
•added 2026/09/28 1:17 p.m.•38 views

CVE-2026-15953

The ABB Protection and control IED manager (PCM600) is vulnerable to a Path Traversal vulnerability during the project archive import process. This issue specifically affects versions through 2.14 . The vulnerability allows for the improper limitation of a pathname to a restricted directory, pote...

5.6CVSS5.8AI score0.00115EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
•added 2026/09/28 1:17 p.m.•10 views

CVE-2026-15953 Path Traversal During Project Archive Import

Improper Limitation of a Pathname to a Restricted Directory 'Path Traversal' vulnerability in ABB Protection and control IED manager PCM600. This issue affects Protection and control IED manager PCM600: through 2.14...

5.6CVSS5.8AI score0.00115EPSS
SaveExploits0References1
EUVD
EUVD
•added 2026/09/28 1:17 p.m.•7 views

EUVD-2026-88254

Improper Limitation of a Pathname to a Restricted Directory 'Path Traversal' vulnerability in ABB Protection and control IED manager PCM600. This issue affects Protection and control IED manager PCM600: through 2.14...

5.6CVSS5.8AI score0.00115EPSS
SaveExploits0References1
CVE
CVE
•added 2026/09/28 1:10 p.m.•28 views

CVE-2026-15952

The ABB Protection and control IED manager (PCM600) is affected by an improper permission assignment vulnerability within the Scheduler Service . This flaw involves incorrect permissions for a critical resource, potentially impacting confidentiality, integrity, and availability. The issue specifi...

7.1CVSS5.8AI score0.00092EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2026/09/28 1:10 p.m.•35 views

CVE-2026-15952 Improper Permission Assignment in Scheduler Service

Incorrect Permission Assignment for Critical Resource vulnerability in ABB Protection and control IED manager PCM600. This issue affects Protection and control IED manager PCM600: through 2.14...

7.1CVSS0.00092EPSS
SaveExploits0References1
Vulnrichment
Vulnrichment
•added 2026/09/28 1:10 p.m.•8 views

CVE-2026-15952 Improper Permission Assignment in Scheduler Service

Incorrect Permission Assignment for Critical Resource vulnerability in ABB Protection and control IED manager PCM600. This issue affects Protection and control IED manager PCM600: through 2.14...

7.1CVSS5.8AI score0.00092EPSS
SaveExploits0References1
EUVD
EUVD
•added 2026/09/28 1:10 p.m.•10 views

EUVD-2026-88248

Incorrect Permission Assignment for Critical Resource vulnerability in ABB Protection and control IED manager PCM600. This issue affects Protection and control IED manager PCM600: through 2.14...

7.1CVSS5.8AI score0.00092EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2026/09/28 12:00 a.m.•6 views

CVE-2026-15953: Improper Limitation of a Pathname to a Restricted Directory

Improper Limitation of a Pathname to a Restricted Directory 'Path Traversal' vulnerability in ABB Protection and control IED manager PCM600. This issue affects Protection and control IED manager PCM600: through 2.14...

5.6CVSS5.8AI score0.00115EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2026/09/28 12:00 a.m.•6 views

PT-2026-99885

Improper Limitation of a Pathname to a Restricted Directory 'Path Traversal' vulnerability in ABB Protection and control IED manager PCM600. This issue affects Protection and control IED manager PCM600: through 2.14...

5.6CVSS5.8AI score0.00115EPSS
SaveExploits0References5
RedhatCVE
RedhatCVE
•added 2026/01/09 8:53 a.m.•15 views

CVE-2021-27426

GE UR IED firmware versions prior to version 8.1x with “Basic” security variant does not allow the disabling of the “Factory Mode,” which is used for servicing the IED by a “Factory” user...

9.8CVSS8.2AI score0.0121EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
•added 2026/01/09 8:53 a.m.•14 views

CVE-2021-27428

GE UR IED firmware versions prior to version 8.1x supports upgrading firmware using UR Setup configuration tool – Enervista UR Setup. This UR Setup tool validates the authenticity and integrity of firmware file before uploading the UR IED. An illegitimate user could upgrade firmware without...

9.8CVSS8.2AI score0.0121EPSS
SaveExploits0References1
EUVD
EUVD
•added 2025/10/07 12:30 a.m.•14 views

EUVD-2021-14180

Malware in sbrugna...

9.8CVSS6.9AI score0.0121EPSS
SaveExploits0References3
EUVD
EUVD
•added 2025/10/03 8:07 p.m.•42 views

EUVD-2022-43204

Malicious code in bioql PyPI...

4.5CVSS5AI score0.00353EPSS
SaveExploits0References1
RedhatCVE
RedhatCVE
•added 2025/06/26 12:25 p.m.•12 views

CVE-2025-39203

A vulnerability exists in the IEC 61850 of the MicroSCADA X SYS600 product. An IEC 61850-8 crafted message content from IED or remote system can cause a denial of service resulting in disconnection loop...

8.3CVSS7.3AI score0.00221EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
•added 2025/06/24 12:00 a.m.•21 views

PT-2025-26718

Name of the Vulnerable Software and Affected Versions: MicroSCADA X SYS600 affected versions not specified Description: A vulnerability exists in the IEC 61850 of the MicroSCADA X SYS600 product, where an IEC 61850-8 crafted message content from IED or remote system can cause a denial of service,...

7.1CVSS6.5AI score0.00221EPSS
SaveExploits0References11
NVD
NVD
•added 2025/03/10 9:15 a.m.•17 views

CVE-2025-27253

A CWE-15 "External Control of System or Configuration Setting" in GE Vernova UR IED family devices from version 7.0 up to 8.60 allows an attacker to provide input that establishes a TCP connection through a port forwarding. The lack of the IP address and port validation may allow the attacker to...

6.1CVSS0.00234EPSS
SaveExploits0References2
Positive Technologies
Positive Technologies
•added 2025/03/10 12:00 a.m.•4 views

PT-2025-10564

Name of the Vulnerable Software and Affected Versions GE Vernova UR IED family devices versions 7.0 through 8.60 Description The issue is related to improper input validation, which allows an attacker to establish a TCP connection through port forwarding. This lack of validation for IP addresses...

6.1CVSS0.00234EPSS
SaveExploits0References11