302 matches found
CISA released Security Advisory on MiCODUS MV720 Global Positioning System (GPS) Tracker
CISA has released an Industrial Controls Systems Advisory ICSA detailing six vulnerabilities that were discovered in MiCODUS MV720 Global Positioning System Tracker. Successful exploitation of these vulnerabilities may allow a remote actor to exploit access and gain control the global positioning...
Siemens Datalogics File Parsing Vulnerability
1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Siemens Equipment: Teamcenter Visualization and JT2Go Vulnerability: Heap-based buffer Overflow 2. UPDATE This updated advisory is a follow-up to the original advisory titled ICSA-22-195-07 Siemens Datalogics file Parsing...
Simcenter Femap and Parasolid
1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Siemens Equipment: Simcenter Femap and Parasolid Vulnerability: Out-of-bounds Read 2. UPDATE This updated advisory is a follow-up to the original advisory titled ICSA-22-195-09 Simcenter Femap and Parasolid Update A that...
CVE-2022-31805
creationtimestamp| type| source ---|---|--- 2022-06-29 02:51:42+00:00| published-proof-of-concept| https://t.me/CyberSecurityTechnologies/6291 2026-03-17 12:00:00+00:00| seen| https://www.cisa.gov/news-events/ics-advisories/icsa-26-076-01...
Mitsubishi Electric MELSEC iQ-R, Q, L Series and MELIPC Series (Update C)
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION : Exploitable remotely/low attack complexity Vendor : Mitsubishi Electric Equipment : MELSEC iQ-R, Q, and L Series CPU Module; MELIPC Series CPU Vulnerability : Improper Resource Locking 2. RISK EVALUATION Successful exploitation of this vulnerability...
Siemens Apache HTTP Server
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Apache HTTP Server Vulnerabilities: NULL Pointer Dereference, Out-of-bounds Write, Server-side Request Forgery SSRF 2. UPDATE INFORMATION This updated advisory is a follow-up to the...
Rockwell Automation Logix Controllers Uncontrolled Resource Consumption (CVE-2022-1797)
The remote OT product is vulnerable as specified in advisory ICSA-22-144-01. - A malformed Class 3 common industrial protocol message with a cached connection can cause a denial-of- service condition in Rockwell Automation Logix Controllers, resulting in a major nonrecoverable fault. If the targe...
Illumina Local Run Manager
1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: Illumina Equipment: Local Run Manager LRM Vulnerabilities: Path Traversal, Unrestricted Upload of File with Dangerous Type, Improper Access Control, Cleartext Transmission of Sensitive Information 2...
Siemens Industrial Devices using libcurl
1. EXECUTIVE SUMMARY CVSS v3 8.1 ATTENTION: Exploitable remotely Vendor: Siemens Equipment: Industrial devices using libcurl Vulnerabilities: Use After Free 2. UPDATE INFORMATION This updated advisory is a follow-up to the original advisory titled ICSA-22-132-13 Siemens Industrial Devices using...
CVE-2022-1039 ICSA-22-104-03 Red Lion DA50N
The weak password on the web user interface can be exploited via HTTP or HTTPS. Once such access has been obtained, the other passwords can be changed. The weak password on Linux accounts can be accessed via SSH or Telnet, the former of which is by default enabled on trusted interfaces. While the...
CVE-2021-43933 ICSA-22-109-03 FANUC ROBOGUIDE Simulation Platform
The affected product is vulnerable to a network-based attack by threat actors sending unimpeded requests to the receiving server, which could cause a denial-of-service condition due to lack of heap memory resources...
CVE-2021-43986 ICSA-22-109-03 FANUC ROBOGUIDE Simulation Platform
The setup program for the affected product configures its files and folders with full access, which may allow unauthorized users permission to replace original binaries and achieve privilege escalation...
CVE-2022-21202 ICSA-22-090-03 Fuji Electric Alpha5
The affected product is vulnerable to an out-of-bounds read, which may result in disclosure of sensitive information...
CVE-2022-24383 ICSA-22-090-03 Fuji Electric Alpha5
The affected product is vulnerable to an out-of-bounds read, which may result in code execution...
CVE-2022-24383 ICSA-22-090-03 Fuji Electric Alpha5
The affected product is vulnerable to an out-of-bounds read, which may result in code execution...
CVE-2022-21228 ICSA-22-090-03 Fuji Electric Alpha5
The affected product is vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code...
CVE-2022-21214 ICSA-22-090-03 Fuji Electric Alpha5
The affected product is vulnerable to a heap-based buffer overflow, which may lead to code execution...
CVE-2022-21168 ICSA-22-090-03 Fuji Electric Alpha5
The affected product is vulnerable due to an invalid pointer initialization, which may lead to information disclosure...
Siemens PROFINET Stack Integrated on Interniche Stack
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...
CVE-2022-1161 ICSA-22-090-05 Rockwell Automation Logix Controllers
An attacker with the ability to modify a user program may change user program code on some ControlLogix, CompactLogix, and GuardLogix Control systems. Studio 5000 Logix Designer writes user-readable program code to a separate location than the executed compiled code, allowing an attacker to chang...