Lucene search
+L

1624 matches found

seebug.org
seebug.org
added 2014/07/01 12:0 a.m.30 views

KingView Log File Parsing Buffer Overflow

No description provided by source. This file is part of the Metasploit Framework and may be subject to redistribution and commercial restrictions. Please see the Metasploit Framework web site for more information on licensing and terms of use. http://metasploit.com/framework/ require 'msf/core'...

7.1AI score
SaveExploits0
seebug.org
seebug.org
added 2014/07/01 12:0 a.m.27 views

Measuresoft ScadaPro <= 4.0.0 - Remote Command Execution

No description provided by source. $Id: scadaprocmdexe.rb 13737 2011-09-16 08:23:59Z sinn3r $ This file is part of the Metasploit Framework and may be subject to redistribution and commercial restrictions. Please see the Metasploit Framework web site for more information on licensing and terms of...

7.1AI score
SaveExploits0
seebug.org
seebug.org
added 2014/07/01 12:0 a.m.35 views

GE Proficy CIMPLICITY gefebt.exe Remote Code Execution

No description provided by source. This module requires Metasploit: http//metasploit.com/download Current source: https://github.com/rapid7/metasploit-framework require 'msf/core' class Metasploit3 Msf::Exploit::Remote Rank = ExcellentRanking include Msf::Auxiliary::Report include Msf::Exploit::E...

7.1AI score
SaveExploits0
ThreatPost
ThreatPost
added 2014/06/30 10:30 a.m.7 views

ICS Malware Found on Vendors' Update Installers

Malware targeting industrial control systems has infected the update installers belonging to three known industrial control vendors, according to an advisory from the Industrial Control Systems Cyber Emergency Response Team ICS-CERT. The Havex remote access Trojan RAT is targeting vendors via...

0.5AI score
SaveExploits0References3
ICS
ICS
added 2014/06/29 6:0 a.m.173 views

Bash Command Injection Vulnerability

OVERVIEW This updated advisory is a follow-up to the original advisory titled ICSA-14-269-01 Bash Command Injection Vulnerability that was published September 26, 2014, on the NCCIC/ICS‑CERT web site. A command injection vulnerability has been reported in the Bourne again shell bash. Bash is the...

10CVSS9.5AI score0.99999EPSS
SaveExploits141References10
ICS
ICS
added 2014/06/19 6:0 a.m.49 views

Schneider Electric SCADA Expert ClearSCADA Vulnerabilities (Update A)

OVERVIEW This updated advisory is a follow-up to the original advisory titled ICSA-14-259-01 Schneider Electric SCADA Expert ClearSCADA Vulnerabilities that was published September 16, 2014, on the NCCIC/ICS-CERT web site. Independent researcher Aditya Sood has identified a weak hashing algorithm...

6.7AI score
SaveExploits0References10
ThreatPost
ThreatPost
added 2014/06/09 11:38 a.m.19 views

ICS-CERT Alert on Easily Hackable Road Signs

A new, remotely exploitable vulnerability in Daktronics’ Vanguard software could make it even easier for attackers to hack electronic road signs, a task that was reportedly never very difficult to begin with. Daktronics’ Vanguard dynamic highway message sign configuration software was initially...

2.5AI score
SaveExploits0References2
ThreatPost
ThreatPost
added 2014/06/04 3:19 p.m.10 views

COPA-DATA Patches DNP3 SCADA Vulnerability

A vulnerability exists in a particular brand of SCADA software that if left unpatched, could trigger a denial of service condition and go on to compromise the software’s communication connections, resulting in system instability. The problem is an improper input validation vulnerability and exist...

1.4AI score
SaveExploits0References3
ThreatPost
ThreatPost
added 2014/05/28 9:41 a.m.9 views

Siemens Fixes DoS Flaw in Rugged OS Devices

Siemens has patched a denial-of-service vulnerability that affected many versions of its Rugged Operating System, software that runs on some of the company’s RuggedCom switches and serial-to-ethernet devices. The vulnerability could enable a remote attacker to cause the Rugged OS software to cras...

1.4AI score
SaveExploits0References1
ThreatPost
ThreatPost
added 2014/05/21 10:31 a.m.8 views

ICS-CERT Confirms Public Utility Compromised Recently

Attackers recently compromised a utility in the United States through an Internet-connected system that gave the attackers access to the utility’s internal control system network. The utility, which has not been named, had remote access enabled on some of its Internet-connected hosts and the...

0.3AI score
SaveExploits0References2
ICS
ICS
added 2014/05/17 6:0 a.m.52 views

Siemens SIMATIC S7-1500 CPU Denial of Service

OVERVIEW Arnaud Ebalard from Agence Nationale de la Sécurité des Systèmes d’Information ANSSI has reported a denial-of-service DoS vulnerability in Siemens SIMATIC S7-1500 CPU. Siemens produced a new firmware version that mitigates this vulnerability and then reported it to NCCIC/ICS-CERT. This...

7.1CVSS6.4AI score0.09696EPSS
SaveExploits3References10
Metasploit
Metasploit
added 2014/05/13 7:17 p.m.55 views

Advantech WebAccess DBVisitor.dll ChartThemeConfig SQL Injection

This module exploits a SQL injection vulnerability found in Advantech WebAccess 7.1. The vulnerability exists in the DBVisitor.dll component, and can be abused through malicious requests to the ChartThemeConfig web service. This module can be used to extract the site and project usernames and...

7.5CVSS0.4AI score0.19243EPSS
SaveExploits4
ThreatPost
ThreatPost
added 2014/05/09 9:56 a.m.11 views

Digi International Gateways Vulnerable to Heartbleed

Wireless Web mesh gateways used everywhere from industrial control environments to home area networks are vulnerable to the Heartbleed OpenSSL vulnerability. The Industrial Control System Computer Emergency Response Team ICS-CERT issued an advisory Thursday warning SCADA and ICS managers with Dig...

7.2AI score
SaveExploits0References8
ThreatPost
ThreatPost
added 2014/04/30 11:29 a.m.9 views

Hacking Traffic Systems for Fun and Chaos

It has been a running joke in the tech industry for years that the hacking scenes in movies are, well, a joke. Hackers in hoodies pushing a few keys and taking down the power grid or causing massive traffic pileups by turning all the stoplights green at once. While those scenes provide endless...

7.4AI score
SaveExploits0References5
ThreatPost
ThreatPost
added 2014/04/28 12:3 p.m.11 views

Siemens Update on Heartbleed Patches in ICS, SCADA

Industrial control equipment manufacturer Siemens has produced a security update that mitigates the OpenSSL Heartbleed vulnerability in its eLAN systems and now its WinCC OA supervisory control and data acquisition SCADA software as well. The company is continuing to work on patches to resolve th...

SaveExploits0References9
ThreatPost
ThreatPost
added 2014/04/21 1:49 p.m.7 views

OpenICS ICS Protocol Decoder Builds Data Dictionaries

Industrial control system security has been called archaic, laughable and even non-existent. Most ICS and SCADA systems weren’t built with the Internet in mind, much less security, but yet they are at the forefront of manufacturing, building automation and critical infrastructure operations...

7AI score
SaveExploits0References4
ThreatPost
ThreatPost
added 2014/04/18 1:20 p.m.13 views

ICS-CERT Warns of Heartbleed Vulnerabilities in Siemens Gear

A number of ICS products from Siemens and Innominate are vulnerable to the OpenSSL heartbleed flaw, some of which do not have updates available yet. The list of products affected by the heartbleed vulnerability continues to grow by the day, with OpenVPN being one of the latest. A researcher on...

0.7AI score
SaveExploits0References3
ThreatPost
ThreatPost
added 2014/04/10 8:47 p.m.11 views

Cyber Intelligence Asia 2014: CERTs and Industrial Security

In March I spoke at Cyber Intelligence Asia 2014, where CERTs from most Asians countries were presented. The fact is that only a few CERTs are now dealing in some way with industrial security, ICS and SCADA matters. One of the best of those is CERT of Japan, which is doing a great job here, and...

1.1AI score
SaveExploits0References7
ThreatPost
ThreatPost
added 2014/04/09 8:0 a.m.9 views

Siemens Ruggedcom Addresses BEAST Flaw in WiMax Products

The BEAST attack on some TLS implementations made major news when it was disclosed, showing that attackers could intercept and decrypt SSL-protected sessions in real time, breaking a significant portion of the confidentiality model of the protocol. Vendors rushed to patch and implement mitigation...

1.7AI score
SaveExploits0References2
ThreatPost
ThreatPost
added 2014/03/28 10:34 a.m.18 views

Patch Available for Schneider Electric Serial Modbus Driver

Schneider Electric, a leading provider of industrial control systems, recently patched a remotely exploitable vulnerability in a driver found in 11 of its products. The Industrial Control Systems Computer Emergency Response Team ICS-CERT released an advisory yesterday alerting users to the...

2.2AI score
SaveExploits0References4
Rows per page