14 matches found
EUVD-2020-19673
Malware in sbrugna...
Moxa NPort IA5150A/IA5250A Series Improper Access Control (CVE-2020-27149)
By exploiting a vulnerability in NPort IA5150A/IA5250A Series before version 1.5, a user with Read Only privilege level can send requests via the web console to have the device's configuration changed. This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-o...
The vulnerability of the serial interface converters NPort IA5150A/IA5250A, IA5450A lies in the storage of passwords in an unencrypted form, allowing attackers to gain unauthorized access to protected information.
The vulnerability of the serial interface converters NPort IA5150A/IA5250A, IA5450A lies in the storage of passwords in an unencrypted form. Exploiting this vulnerability can allow a malicious actor, operating remotely, to gain unauthorized access to protected information...
The vulnerability of the serial interface converters NPort IA5150A/IA5250A, IA5450A lies in the lack of protection for transmitted data. This allows attackers to gain unauthorized access to protected information through Telnet connections.
The vulnerability of the serial interface converters NPort IA5150A/IA5250A, IA5450A lies in the lack of protection for transmitted data. Exploiting this vulnerability can allow an intruder to gain unauthorized access to protected information through Telnet connections...
CVE-2020-27149
By exploiting a vulnerability in NPort IA5150A/IA5250A Series before version 1.5, a user with “Read Only” privilege level can send requests via the web console to have the device’s configuration changed...
CVE-2020-27149
By exploiting a vulnerability in NPort IA5150A/IA5250A Series before version 1.5, a user with “Read Only” privilege level can send requests via the web console to have the device’s configuration changed...
CVE-2020-27149
By exploiting a vulnerability in NPort IA5150A/IA5250A Series before version 1.5, a user with “Read Only” privilege level can send requests via the web console to have the device’s configuration changed...
Design/Logic Flaw
By exploiting a vulnerability in NPort IA5150A/IA5250A Series before version 1.5, a user with “Read Only” privilege level can send requests via the web console to have the device’s configuration changed...
CVE-2020-27149
By exploiting a vulnerability in NPort IA5150A/IA5250A Series before version 1.5, a user with “Read Only” privilege level can send requests via the web console to have the device’s configuration changed...
CVE-2020-27149
CVE-2020-27149 affects MOXA NPort IA5150A/IA5250A Series prior to firmware 1.5. The root cause is an improper access control that lets a Read-Only user send requests via the web console to modify device configuration. Impact is device configuration changes with no conf confidentiality or availabi...
CVE-2020-27149: Undefined Security Weakness
By exploiting a vulnerability in NPort IA5150A/IA5250A Series before version 1.5, a user with “Read Only” privilege level can send requests via the web console to have the device’s configuration changed...
PT-2021-3064
Name of the Vulnerable Software and Affected Versions NPort IA5000A Series devices affected versions not specified NPort IA5150A/IA5250A, IA5450A devices affected versions not specified Description The issue is related to the use of Telnet for network device management, which does not support...
PT-2021-3065
Name of the Vulnerable Software and Affected Versions NPort IA5150A/IA5250A, IA5450A versions affected versions not specified NPort IA5000A Series versions affected versions not specified Description The issue is related to the storage of passwords in plaintext. This could allow a remote attacker...
PT-2021-3066
Name of the Vulnerable Software and Affected Versions NPort IA5150A/IA5250A Series versions prior to 1.5 Description The issue is related to inadequate access control in the NPort IA5150A/IA5250A Series, allowing a user with "Read Only" privilege level to send requests via the web console to chan...