Lucene search
+L

155 matches found

NVD
NVD
added 2023/01/30 11:15 a.m.19 views

CVE-2022-2988

A CWE-787: Out-of-bounds Write vulnerability exists that could cause sensitive information leakage when accessing a malicious web page from the commissioning software. Affected Products: SoMachine HVAC Versions prior to V2.1.0, EcoStruxure Machine Expert – HVAC Versions prior to V1.4.0...

7.5CVSS5.1AI score0.00426EPSS
SaveExploits0References1
OSV
OSV
added 2023/01/30 11:15 a.m.10 views

CVE-2022-2988

A CWE-787: Out-of-bounds Write vulnerability exists that could cause sensitive information leakage when accessing a malicious web page from the commissioning software. Affected Products: SoMachine HVAC Versions prior to V2.1.0, EcoStruxure Machine Expert – HVAC Versions prior to V1.4.0...

7.5CVSS5.8AI score0.00426EPSS
SaveExploits0References1
Prion
Prion
added 2023/01/30 11:15 a.m.22 views

Out-of-bounds

A CWE-787: Out-of-bounds Write vulnerability exists that could cause sensitive information leakage when accessing a malicious web page from the commissioning software. Affected Products: SoMachine HVAC Versions prior to V2.1.0, EcoStruxure Machine Expert – HVAC Versions prior to V1.4.0...

5CVSS7.2AI score0.00426EPSS
SaveExploits0References1Affected Software2
Cvelist
Cvelist
added 2023/01/30 12:00 a.m.21 views

CVE-2022-2988

A CWE-787: Out-of-bounds Write vulnerability exists that could cause sensitive information leakage when accessing a malicious web page from the commissioning software. Affected Products: SoMachine HVAC Versions prior to V2.1.0, EcoStruxure Machine Expert – HVAC Versions prior to V1.4.0...

4.3CVSS7.5AI score0.00426EPSS
SaveExploits0References1
CVE
CVE
added 2023/01/30 12:00 a.m.62 views

CVE-2022-2988

The CVE-2022-2988 entry concerns a CWE-787 Out-of-bounds Write vulnerability in Schneider Electric SoMachine HVAC and EcoStruxure Machine Expert – HVAC. Affects SoMachine HVAC prior to V2.1.0 and EcoStruxure Machine Expert – HVAC prior to V1.4.0. Root cause/impact: when a malicious web page is ac...

7.5CVSS7.2AI score0.00426EPSS
SaveExploits0References1Affected Software2
Vulnrichment
Vulnrichment
added 2023/01/30 12:00 a.m.10 views

CVE-2022-2988

A CWE-787: Out-of-bounds Write vulnerability exists that could cause sensitive information leakage when accessing a malicious web page from the commissioning software. Affected Products: SoMachine HVAC Versions prior to V2.1.0, EcoStruxure Machine Expert – HVAC Versions prior to V1.4.0...

4.3CVSS6.3AI score0.00426EPSS
SaveExploits0References1
Positive Technologies
Positive Technologies
added 2023/01/10 12:00 a.m.10 views

PT-2023-1357 · Schneider Electric · Ecostruxure Machine Expert – Hvac +1

Name of the Vulnerable Software and Affected Versions: SoMachine HVAC versions prior to V2.1.0 EcoStruxure Machine Expert – HVAC versions prior to V1.4.0 Description: The issue is related to a lack of protection for service data, which could allow a remote attacker to disclose protected informati...

7.8CVSS7.4AI score0.00426EPSS
SaveExploits0References5
NVD
NVD
added 2022/08/31 4:15 p.m.34 views

CVE-2022-37122

Carel pCOWeb HVAC BACnet Gateway 2.1.0, Firmware: A2.1.0 - B2.1.0, Application Software: 2.15.4A Software v16 13020200 suffers from an unauthenticated arbitrary file disclosure vulnerability. Input passed through the 'file' GET parameter through the 'logdownload.cgi' Bash script is not properly...

7.5CVSS0.19238EPSS
SaveExploits3References3
Prion
Prion
added 2022/08/31 4:15 p.m.21 views

Directory traversal

Carel pCOWeb HVAC BACnet Gateway 2.1.0, Firmware: A2.1.0 - B2.1.0, Application Software: 2.15.4A Software v16 13020200 suffers from an unauthenticated arbitrary file disclosure vulnerability. Input passed through the 'file' GET parameter through the 'logdownload.cgi' Bash script is not properly...

5CVSS7.5AI score0.19238EPSS
SaveExploits3References3Affected Software3
Cvelist
Cvelist
added 2022/08/31 3:47 p.m.48 views

CVE-2022-37122

Carel pCOWeb HVAC BACnet Gateway 2.1.0, Firmware: A2.1.0 - B2.1.0, Application Software: 2.15.4A Software v16 13020200 suffers from an unauthenticated arbitrary file disclosure vulnerability. Input passed through the 'file' GET parameter through the 'logdownload.cgi' Bash script is not properly...

7.6AI score0.19238EPSS
SaveExploits3References3
EUVD
EUVD
added 2022/08/31 3:47 p.m.9 views

EUVD-2022-39775

Carel pCOWeb HVAC BACnet Gateway 2.1.0, Firmware: A2.1.0 - B2.1.0, Application Software: 2.15.4A Software v16 13020200 suffers from an unauthenticated arbitrary file disclosure vulnerability. Input passed through the 'file' GET parameter through the 'logdownload.cgi' Bash script is not properly...

7.5CVSS7.5AI score0.19238EPSS
SaveExploits3References3
CVE
CVE
added 2022/08/31 3:47 p.m.68 views

CVE-2022-37122

Carel pCOWeb HVAC BACnet Gateway 2.1.0 (Firmware A2.1.0–B2.1.0; Software v16 13020200; App 2.15.4A) is affected by an unauthenticated arbitrary file disclosure due to improper verification of the 'file' GET parameter in logdownload.cgi. The vulnerability allows directory traversal to disclose arb...

7.5CVSS7.4AI score0.19238EPSS
SaveExploits3References3Affected Software1
CNNVD
CNNVD
added 2022/08/31 12:00 a.m.10 views

Carel pCOWeb HVAC BACnet Gateway 路径遍历漏洞

Carel pCOWeb is a programmable control card. A security vulnerability exists in Carel pCOWeb HVAC BACnet Gateway 2.1.0, Firmware versions A2.1.0 - B2.1.0, Application Software version 2.15.4A, and Software v16 13020200, which stems from the presence of an unauthenticated Arbitrary File Disclosure...

7.5CVSS6.8AI score0.19238EPSS
SaveExploits3References4
zdt
zdt
added 2022/07/31 12:00 a.m.257 views

Carel pCOWeb HVAC BACnet Gateway 2.1.0 - Directory Traversal Vulnerability

Exploit Title: Carel pCOWeb HVAC BACnet Gateway 2.1.0 - Directory Traversal Exploit Author: LiquidWorm Vendor: CAREL INDUSTRIES S.p.A. Product web page: https://www.carel.com Affected version: Firmware: A2.1.0 - B2.1.0 Application Software: 2.15.4A Software version: v16 13020200 Summary: pCO...

0.3AI score
SaveExploits0
Exploit DB
Exploit DB
added 2022/07/29 12:00 a.m.335 views

Carel pCOWeb HVAC BACnet Gateway 2.1.0 - Directory Traversal

Exploit Title: Carel pCOWeb HVAC BACnet Gateway 2.1.0 - Directory Traversal Exploit Author: LiquidWorm Vendor: CAREL INDUSTRIES S.p.A. Product web page: https://www.carel.com Affected version: Firmware: A2.1.0 - B2.1.0 Application Software: 2.15.4A Software version: v16 13020200 Summary: pCO...

5.3AI score
SaveExploits0
zdt
zdt
added 2022/07/01 12:00 a.m.371 views

Carel pCOWeb HVAC BACnet Gateway 2.1.0 Unauthenticated Directory Traversal Vulnerability

Carel pCOWeb HVAC BACnet Gateway version 2.1.0 suffers from an unauthenticated arbitrary file disclosure vulnerability. Input passed through the file GET parameter through the logdownload.cgi bash script is not properly verified before being used to download log files. This can be exploited to...

7.2AI score
SaveExploits0
Zero Science Lab
Zero Science Lab
added 2022/06/30 12:00 a.m.473 views

Carel pCOWeb HVAC BACnet Gateway 2.1.0 Unauthenticated Directory Traversal

Summary pCO sistema is the solution CAREL offers its customers for managing HVAC/R applications and systems. It consists of programmable controllers, user interfaces, gateways and communication interfaces, remote management systems to offer the OEMs working in HVAC/R a control system that is...

7.5CVSS7.2AI score0.19238EPSS
SaveExploits3
CNVD
CNVD
added 2022/05/12 12:00 a.m.24 views

Unspecified Vulnerability in Siemens Desigo PXC and DXR Devices (CNVD-2022-37376)

Desigo DXR2 controllers are programmable automation stations to support the standard control needs of end HVAC equipment and TRA Total Room Automation applications. the Desigo PXC3 series of automation stations can be used in buildings where functionality and flexibility are more demanding. Use...

5.3CVSS1AI score0.01041EPSS
SaveExploits0References1
CNVD
CNVD
added 2022/05/11 12:00 a.m.25 views

Siemens Desigo PXC and DXR Devices Uncontrolled Resource Consumption Vulnerability

Desigo DXR2 controllers are programmable automation stations to support the standard control needs of end HVAC equipment and TRA Total Room Automation applications. the Desigo PXC3 series of automation stations can be used in buildings where functionality and flexibility are more demanding. Use...

6.5CVSS1AI score0.00822EPSS
SaveExploits0References1
CNVD
CNVD
added 2022/05/11 12:00 a.m.60 views

Siemens Desigo PXC and DXR Devices Remote Code Execution Vulnerability

The Desigo PXC4 building automation controller is designed for HVAC system control. It is a compact device with built-in IOs that can be expanded to meet your needs with additional TX-IO modules.The Desigo PXC5 is a freely programmable controller for BACnet system-level functions such as alarm...

9CVSS3.3AI score0.01911EPSS
SaveExploits0References1
Rows per page