Lucene search
+L

7 matches found

EUVD
EUVD
•added 2025/10/07 12:30 a.m.•17 views

EUVD-2019-7095

Malware in sbrugna...

7.5CVSS7.3AI score0.01673EPSS
SaveExploits0References2
RedhatCVE
RedhatCVE
•added 2025/05/22 8:15 a.m.•21 views

CVE-2019-16301

An issue was discovered in Open Network Operating System ONOS 1.14. In the virtual tenant network application org.onosproject.vtn, the host event listener does not handle the following event types: HOSTMOVED. In combination with other applications, this could lead to the absence of intended code...

7.5CVSS7AI score0.01673EPSS
SaveExploits0References1
Cvelist
Cvelist
•added 2020/02/20 9:43 p.m.•37 views

CVE-2019-16301

An issue was discovered in Open Network Operating System ONOS 1.14. In the virtual tenant network application org.onosproject.vtn, the host event listener does not handle the following event types: HOSTMOVED. In combination with other applications, this could lead to the absence of intended code...

7.7AI score0.01673EPSS
SaveExploits0References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/02/20 12:00 a.m.•6 views

CVE-2019-16297: Improper Handling of Exceptional Conditions

An issue was discovered in Open Network Operating System ONOS 1.14. In the P4 tutorial application org.onosproject.p4tutorial, the host event listener does not handle the following event types: HOSTMOVED, HOSTREMOVED, HOSTUPDATED. In combination with other applications, this could lead to the...

7.5CVSS7.3AI score0.01673EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/02/20 12:00 a.m.•3 views

CVE-2019-16302: Improper Handling of Exceptional Conditions

An issue was discovered in Open Network Operating System ONOS 1.14. In the Ethernet VPN application org.onosproject.evpnopenflow, the host event listener does not handle the following event types: HOSTMOVED, HOSTUPDATED. In combination with other applications, this could lead to the absence of...

7.5CVSS7.3AI score0.01673EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/02/20 12:00 a.m.•2 views

CVE-2019-16298: Improper Handling of Exceptional Conditions

An issue was discovered in Open Network Operating System ONOS 1.14. In the virtual broadband network gateway application org.onosproject.virtualbng, the host event listener does not handle the following event types: HOSTMOVED, HOSTREMOVED, HOSTUPDATED. In combination with other applications, this...

7.5CVSS7.3AI score0.01673EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2020/02/20 12:00 a.m.•3 views

CVE-2019-16301: Improper Handling of Exceptional Conditions

An issue was discovered in Open Network Operating System ONOS 1.14. In the virtual tenant network application org.onosproject.vtn, the host event listener does not handle the following event types: HOSTMOVED. In combination with other applications, this could lead to the absence of intended code...

7.5CVSS7.3AI score0.01673EPSS
SaveExploits0References2
Rows per page
Query Builder