70 matches found
Cross-site Request Forgery (CSRF)
Overview clockworkweb is a web interface for Clockwork Affected versions of this package are vulnerable to Cross-site Request Forgery CSRF via the homecontroller.rb class. Remediation Upgrade clockworkweb to version 0.1.2 or higher. References - GitHub Commit - GitHub Issue...
Information Disclosure
pghero is vulnerable to Information Disclosure. The vulnerability exists because the explain function in homecontroller.rb does not properly handle sensitive information in the error message of query results, allowing an attacker to access sensitive information...
Schneider Electric SpaceLogic C-Bus Home Controller (5200WHC2) - Remote Code Execution Vulnerability
Exploit Title: Schneider Electric SpaceLogic C-Bus Home Controller 5200WHC2 - Remote Code Execution Exploit Author: LiquidWorm SpaceLogic.ps1 Schneider Electric SpaceLogic C-Bus Home Controller 5200WHC2 Remote Root Exploit Vendor: Schneider Electric SE Product web page: https://www.se.com...
Schneider Electric SpaceLogic C-Bus Home Controller (5200WHC2) - Remote Code Execution
Exploit Title: Schneider Electric SpaceLogic C-Bus Home Controller 5200WHC2 - Remote Code Execution Exploit Author: LiquidWorm SpaceLogic.ps1 Schneider Electric SpaceLogic C-Bus Home Controller 5200WHC2 Remote Root Exploit Vendor: Schneider Electric SE Product web page: https://www.se.com...
Schneider Electric SpaceLogic C-Bus Home Controller (5200WHC2) Remote Root Exploit
Schneider Electric SpaceLogic C-Bus Home Controller 5200WHC2 versions 1.31.460 and below suffer from an authenticated OS command injection vulnerability. This can be exploited to inject and execute arbitrary shell commands as the root user via the name GET parameter in delsnap.pl Perl/CGI script...
Schneider Electric SpaceLogic C-Bus Home Controller (5200WHC2) Remote Root
SpaceLogic.ps1 Schneider Electric SpaceLogic C-Bus Home Controller 5200WHC2 Remote Root Exploit Vendor: Schneider Electric SE Product web page: https://www.se.com https://www.se.com/ww/en/product/5200WHC2/home-controller-spacelogic-cbus-cbus-ip-free-standing-24v-dc/...
Schneider Electric SpaceLogic C-Bus Home Controller (5200WHC2) Remote Root Exploit
Summary SpaceLogic C-Bus Home Automation System Lighting control and automation solutions for buildings of the future, part of SpaceLogic. SpaceLogic C-Bus is a powerful, fully integrated system that can control and automate lighting and many other electrical systems and products. The SpaceLogic...
The vulnerability of the microprogrammed software of the SpaceLogic C-Bus Home Controller (5200WHC2) arises from the failure to take measures to neutralize the special elements used in the operating system’s commands. This vulnerability allows a intruder to execute arbitrary commands.
The vulnerability of the microprogrammed software of the SpaceLogic C-Bus Home Controller 5200WHC2 exists due to the lack of measures taken to neutralize the special elements used in the operating system commands. Exploiting this vulnerability allows a remote attacker to execute arbitrary command...
CVE-2022-34753
A CWE-78: Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability exists that could cause remote root exploit when the command is compromised. Affected Products: SpaceLogic C-Bus Home Controller 5200WHC2, formerly known as C-Bus Wiser Homer Controlle...
Command injection
A CWE-78: Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability exists that could cause remote root exploit when the command is compromised. Affected Products: SpaceLogic C-Bus Home Controller 5200WHC2, formerly known as C-Bus Wiser Homer Controlle...
CVE-2022-34753
A CWE-78: Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability exists that could cause remote root exploit when the command is compromised. Affected Products: SpaceLogic C-Bus Home Controller 5200WHC2, formerly known as C-Bus Wiser Homer Controlle...
CVE-2022-34753
CVE-2022-34753 affects Schneider Electric SpaceLogic C-Bus Home Controller (5200WHC2), formerly C-Bus Wiser Home Controller MK2, up to version 1.31.460 (firmware 604). The vulnerability is an authenticated OS command injection vulnerability that allows remote root execution when a crafted command...
CVE-2022-34753
A CWE-78: Improper Neutralization of Special Elements used in an OS Command 'OS Command Injection' vulnerability exists that could cause remote root exploit when the command is compromised. Affected Products: SpaceLogic C-Bus Home Controller 5200WHC2, formerly known as C-Bus Wiser Homer Controlle...
GHSA-9GGP-5RF4-X7Q9 Fat Free CRM vulnerable to SQL Injection
Multiple SQL injection vulnerabilities in app/controllers/homecontroller.rb in Fat Free CRM before 0.12.1 allow remote authenticated users to execute arbitrary SQL commands via 1 the homepage timeline feature or 2 the activity feature...
CVE-2019-15498
cgi-bin/cmh/webcam.sh in Vera Edge Home Controller 1.7.4452 allows remote unauthenticated users to execute arbitrary OS commands via --output argument injection in the username parameter to /cgi-bin/cmh/webcam.sh...
CVE-2019-15498
CVE-2019-15498 affects Vera Edge Home Controller 1.7.4452. The vulnerability is a remote command-injection in the CGI script at cgi-bin/cmh/webcam.sh, exploitable by unauthenticated users via the username parameter’s --output argument injection, enabling arbitrary OS command execution. The issue ...
CVE-2019-13598
LuaUPnP in Vera Edge Home Controller 1.7.4452 allows remote unauthenticated users to execute arbitrary OS commands via the code parameter to /port3480/datarequest because the "No unsafe lua allowed" code block is skipped...
Command injection
LuaUPnP in Vera Edge Home Controller 1.7.4452 allows remote unauthenticated users to execute arbitrary OS commands via the code parameter to /port3480/datarequest because the "No unsafe lua allowed" code block is skipped...
CVE-2019-13598
CVE-2019-13598 affects Vera Edge Home Controller (version 1.7.4452) via LuaUPnP. A remote, unauthenticated attacker can trigger arbitrary OS commands by passing the code parameter to /port_3480/data_request, because the expected safety check for unsafe Lua code is skipped. This is a remote code e...
CVE-2019-11896
A potential incorrect privilege assignment vulnerability exists in the 3rd party pairing mechanism of the Bosch Smart Home Controller SHC before 9.8.907 that may result in a restricted app obtaining default app permissions. In order to exploit the vulnerability, the adversary needs to have...