8 matches found
EUVD-2025-199998
A cross-site scripting XSS vulnerability exists in the Blood Bank Management System 1.0 within the updateprofile.php and hprofile.php components. The application fails to properly sanitize or encode user-supplied input before rendering it in response. An attacker can inject malicious JavaScript...
CVE-2025-63527
CVE-2025-63527 affects Blood Bank Management System 1.0. The XSS flaw exists in updateprofile.php and hprofile.php where user input is not properly sanitized/encoded, allowing injection of JavaScript via hname, hemail, hpassword, hphone, and hcity parameters. This input is rendered in the respons...
CVE-2025-10440
A vulnerability has been found in D-Link DI-8100, DI-8100G, DI-8200, DI-8200G, DI-8003 and DI-8003G 16.07.26A1/17.12.20A1/19.12.10A1. Affected by this vulnerability is the function sub4621DC of the file usbpaswd.asp of the component jhttpd. The manipulation of the argument hname leads to os comma...
CVE-2025-10440 D-Link DI-8100/DI-8100G/DI-8200/DI-8200G/DI-8003/DI-8003G jhttpd usb_paswd.asp sub_4621DC os command injection
A vulnerability has been found in D-Link DI-8100, DI-8100G, DI-8200, DI-8200G, DI-8003 and DI-8003G 16.07.26A1/17.12.20A1/19.12.10A1. Affected by this vulnerability is the function sub4621DC of the file usbpaswd.asp of the component jhttpd. The manipulation of the argument hname leads to os comma...
D-Link多款产品 操作系统命令注入漏洞
D-Link DI-8100 and others are products of China AUO D-Link.D-Link DI-8100 is a wireless broadband router designed for small and medium-sized network environments.D-Link DI-8100G is a Gigabit Internet Behavior Management certified router.D-Link DI-8200 is an enterprise-class router. An OS command...
CVE-2025-8829
CVE-2025-8829 affects Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. The vulnerability is in the um_red function of the file /goform/RP_setBasicAuto; manipulation of the hname parameter leads to OS command injection. The attack can be launched remotely, and public discl...
CVE-2025-8829 Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 RP_setBasicAuto um_red os command injection
A vulnerability was identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this vulnerability is the function umred of the file /goform/RPsetBasicAuto. The manipulation of the argument hname leads to os command injection. The attack can be launched...
Linksys多款产品 命令注入漏洞
The Linksys RE6250, among others, is a wireless extender from Linksys USA. A command injection vulnerability exists in various Linksys products, which stems from improper manipulation of the hname parameter in the umred function, which could lead to os command injection. The following products an...