CVE-2026-47717
FUXA 1.3.0 is vulnerable: GET /api/project allows unauthenticated/guest-context access to full project data despite secureEnabled, due to secureFnc auto-generating a guest token. Impact includes server-side scripts, device configurations, HMI views (SVG and bindings), and alarm definitions. Versi...
CVE-2026-47717 FUXA's Unauthenticated Project Data Disclosure Exposes Server-Side Scripts and Device Configurations
FUXA is a web-based Process Visualization SCADA/HMI/Dashboard software. In fuxa-server version 1.3.0, the GET /api/project endpoint exposes sensitive project configuration data to guest-context requests even when secureEnabled is enabled. Version 1.3.1 fixes the issue...
CVE-2026-60134
Weintek cMT3092X HMI allows a non-privileged user to modify cookies to gain elevated privileges...
CVE-2026-60134
Weintek cMT3092X HMI allows a non-privileged user to modify cookies to gain elevated privileges...
PT-2026-64422
Name of the Vulnerable Software and Affected Versions Weintek cMT3092X affected versions not specified Description The Weintek cMT3092X HMI contains a flaw where it relies on cookies without proper validation and integrity checking during security decisions. This allows a non-privileged user to...
CVE-2026-9716
CWE-476 NULL Pointer Dereference vulnerability exists that could cause a denial-of-service condition, rendering the device’s HMI and configuration functionality unavailable when malformed requests are received over exposed network interfaces...
PT-2026-44163
Name of the Vulnerable Software and Affected Versions fuxa-server version 1.3.0 Description An API logic flaw in the web-based Process Visualization software allows unauthenticated attackers to leak critical project configurations and operational data. The '/api/project' endpoint exposes sensitiv...
CODESYS多款产品 安全漏洞
CODESYS Control and others are products of the German company CODESYS. CODESYS Control is a set of industrial control programming software. CODESYS is an industrial control automation software. CODESYS HMI is a visualization software. Several CODESYS products have security vulnerabilities. These...
Siemens SIMATIC HMI Comfort Panels 安全漏洞
Siemens SIMATIC HMI Comfort Panels are touchscreen devices produced by the German company Siemens. There are security vulnerabilities in Siemens SIMATIC HMI Comfort Panels. These vulnerabilities stem from improper restrictions on access to web browsers through the control panel. This allows...
FUXA 1.2.8 - Authentication Bypass + RCE Exploit
Exploit Title: FUXA 1.2.8 - Authentication Bypass + RCE Exploit Date: 2026-02-25 Exploit Author: Joshua van der Poll https://github.com/joshuavanderpoll/ Software Link: https://github.com/frangoteam/FUXA/tree/v1.2.8 Vendor Homepage: https://github.com/frangoteam/FUXA Version: FUXA 1.2.8. Do not u...
Mitsubishi Electric多款产品 安全漏洞
Mitsubishi Electric GENESIS64 and other products are developed by Mitsubishi Electric Corporation of Japan. Mitsubishi Electric GENESIS64 is a SCADA suite. Mitsubishi Electric ICONICS Suite is a monitoring system for digital factories and intelligent buildings. Mitsubishi Electric MobileHMI is a...
PT-2026-30801
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric MobileHMI versions 10.97.3 and prior, Mitsubishi Electric Hyper Historian versions 10.97.3 and...
CVE-2021-27384
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7" & 15" incl. SIPLUS variants All versions V15.1 Update 6, SIMATIC HMI Comfort Outdoor Panels V16 7" & 15" incl. SIPLUS variants All versions V16 Update 4, SIMATIC HMI Comfort Panels V15 4" - 22" incl. SIPLUS...
CVE-2026-4760
From Panorama Web HMI, an attacker can gain read access to certain Web HMI server files, if he knows their paths and if these files are accessible to the Servin process execution account. Installations based on Panorama Suite 2022-SP1 22.50.005 are vulnerable unless update PS-2210-02-4079 or high...
EUVD-2026-15402
From Panorama Web HMI, an attacker can gain read access to certain Web HMI server files, if he knows their paths and if these files are accessible to the Servin process execution account. Installations based on Panorama Suite 2022-SP1 22.50.005 are vulnerable unless update PS-2210-02-4079 or high...
CVE-2026-4760
From Panorama Web HMI, an attacker can gain read access to certain Web HMI server files, if he knows their paths and if these files are accessible to the Servin process execution account. Installations based on Panorama Suite 2022-SP1 22.50.005 are vulnerable unless update PS-2210-02-4079 or high...
CVE-2026-4760
From CVE-2026-4760, Panorama Web HMI allows an attacker to gain read access to certain Web HMI server files if the attacker knows the file paths and the files are accessible to the Servin process execution account. Affected installations include Panorama Suite 2022-SP1 (22.50.005) unless PS-2210-...
CVE-2026-4760 Potential unauthorized access to files on the Web HMI server host
From Panorama Web HMI, an attacker can gain read access to certain Web HMI server files, if he knows their paths and if these files are accessible to the Servin process execution account. Installations based on Panorama Suite 2022-SP1 22.50.005 are vulnerable unless update PS-2210-02-4079 or high...
CVE-2026-4760 Potential unauthorized access to files on the Web HMI server host
From Panorama Web HMI, an attacker can gain read access to certain Web HMI server files, if he knows their paths and if these files are accessible to the Servin process execution account. Installations based on Panorama Suite 2022-SP1 22.50.005 are vulnerable unless update PS-2210-02-4079 or high...
Codra Panorama Suite 安全漏洞
Codra Panorama Suite is an industrial process monitoring software platform developed by the French company Codra. There is a security vulnerability in Codra Panorama Suite, which allows attackers to potentially read files on the Web HMI server...