RedhatCVE
RedhatCVE
added 2026/01/07 9:53 a.m.11 views

CVE-2013-7395

ZOLL Defibrillator / Monitor X Series has a default 1 supervisor password and 2 service password, which allows physically proximate attackers to modify device configuration and cause a denial of service adverse human health effects...

4.9CVSS7AI score0.00355EPSS
SaveExploits0References1
EUVD
EUVD
added 2025/10/07 12:30 a.m.8 views

EUVD-2007-6712

Malware in sbrugna...

4.9CVSS6.4AI score0.0041EPSS
SaveExploits0References5
NVD
NVD
added 2014/08/12 4:55 p.m.15 views

CVE-2007-6756

ZOLL Defibrillator / Monitor M Series, E Series, and R Series have a default password for System Configuration mode, which allows physically proximate attackers to modify device configuration and cause a denial of service adverse human health effects...

4.9CVSS6.7AI score0.0041EPSS
SaveExploits0References4
NVD
NVD
added 2014/08/12 4:55 p.m.10 views

CVE-2013-7395

ZOLL Defibrillator / Monitor X Series has a default 1 supervisor password and 2 service password, which allows physically proximate attackers to modify device configuration and cause a denial of service adverse human health effects...

4.9CVSS6.6AI score0.00355EPSS
SaveExploits0References1
Prion
Prion
added 2014/08/12 4:55 p.m.14 views

Default credentials

ZOLL Defibrillator / Monitor M Series, E Series, and R Series have a default password for System Configuration mode, which allows physically proximate attackers to modify device configuration and cause a denial of service adverse human health effects...

4.9CVSS7.2AI score0.0041EPSS
SaveExploits0References4
Cvelist
Cvelist
added 2014/08/12 4:00 p.m.26 views

CVE-2007-6756

ZOLL Defibrillator / Monitor M Series, E Series, and R Series have a default password for System Configuration mode, which allows physically proximate attackers to modify device configuration and cause a denial of service adverse human health effects...

6.7AI score0.0041EPSS
SaveExploits0References4
NVD
NVD
added 2011/09/02 11:55 p.m.24 views

CVE-2011-3386

Unspecified vulnerability in Medtronic Paradigm wireless insulin pump 512, 522, 712, and 722 allows remote attackers to modify the delivery of an insulin bolus dose and cause a denial of service adverse human health effects via unspecified vectors involving wireless communications and knowledge o...

4CVSS6.6AI score0.0145EPSS
SaveExploits0References8
Prion
Prion
added 2011/09/02 11:55 p.m.21 views

Code injection

Unspecified vulnerability in Medtronic Paradigm wireless insulin pump 512, 522, 712, and 722 allows remote attackers to modify the delivery of an insulin bolus dose and cause a denial of service adverse human health effects via unspecified vectors involving wireless communications and knowledge o...

4CVSS7.2AI score0.0145EPSS
SaveExploits0References8Affected Software1