CVE-2019-6578
A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All Versions with option G28, SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All Versions with option G28. A denial of service...
Code injection
A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46, SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All...
Denial of service
A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All Versions with option G28, SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All Versions with option G28. A denial of service...
CVE-2019-6574
CVE-2019-6574 affects Siemens SINAMICS PERFECT HARMONY GH180 (NXG I/NXG II) with MLFBs 6SR2...-, 6SR3...-, 6SR4...- (options G21–G46). Root cause: improperly configured Parameter Read/Write execution via Fieldbus network, enabling a remote attacker with network access to restart the controller an...
CVE-2019-6578
A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All Versions with option G28, SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All Versions with option G28. A denial of service...
CVE-2019-6574
A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All Versions with option G21, G22, G23, G26, G28, G31, G32, G38, G43 or G46, SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- All...
CVE-2019-6578
CVE-2019-6578 affects Siemens SINAMICS PERFECT HARMONY GH180 drives (NXG I/II) with option G28, where an attacker with network access can trigger a denial-of-service via uncontrolled resource consumption on the Ethernet Modbus interface. No privileges or user interaction are required; impact is a...
ICSA-19-134-06 Siemens SINAMICS PERFECT HARMONY GH180 Fieldbus Network
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: SINAMICS PERFECT HARMONY GH180 Fieldbus Network Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could cause a...
ICSA-19-134-05 Siemens SINAMICS PERFECT HARMONY GH180 Drives NXG I and NXG II
1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low skill level to exploit Vendor: Siemens Equipment: SINAMICS PERFECT HARMONY GH180 Drives NXG I and NXG II Vulnerability: Uncontrolled Resource Consumption 2. RISK EVALUATION Successful exploitation of this vulnerability could...
Multiple Siemens Products Access Control Error Vulnerabilities
Siemens SINAMICS PERFECT HARMONY GH180 is a high-voltage AC frequency converter from Siemens Germany. An access control error vulnerability exists in several Siemens products. The vulnerability stems from a network system or product that does not properly restrict access to resources from...
BSides SF 2019: Remote-Root Bug in Logitech Harmony Hub Patched and Explained
SAN FRANCISCO – Users of Logitech’s Harmony Hub have been wide open to an attack for years because of four unpatched vulnerabilities that left any IoT device connected at risk to remote takeover. The bugs were patched by Logitech in November, but for the first time the researchers that discovered...
Logitech Harmony Hub Command Injection Vulnerability
Logitech Harmony Hub is a remote control device from Logitech USA. A command injection vulnerability exists in Logitech Harmony Hub versions prior to 4.15.206, which can be exploited by a remote attacker to execute application-defined commands e.g., harmony.system?systeminfo by sending a speciall...
Logitech Harmony Hub OS Command Injection Vulnerability
Logitech Harmony Hub is a remote control device from Logitech USA. An operating system command injection vulnerability exists in Logitech Harmony Hub versions prior to 4.15.206, which can be exploited by an attacker to inject operating system commands by sending a time update request...
Authentication flaw
The XMPP server in Logitech Harmony Hub before version 4.15.206 is vulnerable to authentication bypass via a crafted XMPP request. Remote attackers can use this vulnerability to gain access to the local API...
CVE-2018-15723
The Logitech Harmony Hub before version 4.15.206 is vulnerable to application level command injection via crafted HTTP request. An unauthenticated remote attacker can leverage this vulnerability to execute application defined commands e.g. harmony.system?systeminfo...
CVE-2018-15721
The XMPP server in Logitech Harmony Hub before version 4.15.206 is vulnerable to authentication bypass via a crafted XMPP request. Remote attackers can use this vulnerability to gain access to the local API...
Hardcoded credentials
Logitech Harmony Hub before version 4.15.206 contained two hard-coded accounts in the XMPP server that gave remote users access to the local API...
CVE-2018-15720
Logitech Harmony Hub before version 4.15.206 contained two hard-coded accounts in the XMPP server that gave remote users access to the local API...
Command injection
The Logitech Harmony Hub before version 4.15.206 is vulnerable to OS command injection via the time update request. A remote server or man in the middle can inject OS commands with a properly formatted response...
CVE-2018-15720
Logitech Harmony Hub before version 4.15.206 contained two hard-coded accounts in the XMPP server that gave remote users access to the local API...