Philips Brilliance CT Scanners Hard-Coded Certificate Vulnerability

The Philips Brilliance 64, among others, is a CT scanner device from the Dutch company Philips. A security vulnerability exists in a number of Philips Brilliance CT devices that stems from software in the device that uses hard-coded credentials e.g., passwords or encryption keys. An attacker coul...

7.8CVSS7AI score0.00325EPSS
SaveExploits0References1
Packet Storm
Packet Storm
added 2018/05/04 12:00 a.m.73 views

TP-Link EAP Controller CSRF / Hard-Coded Key / XSS

Core Security - Corelabs Advisory http://corelabs.coresecurity.com/ TP-Link EAP Controller Multiple Vulnerabilities 1. Advisory Information Title: TP-Link EAP Controller Multiple Vulnerabilities Advisory ID: CORE-2018-0001 Advisory URL:...

0.5AI score0.01442EPSS
SaveExploits7
OSV
OSV
added 2018/05/03 6:29 p.m.9 views

CVE-2018-10167

The web application backup file in the TP-Link EAP Controller and Omada Controller versions 2.5.4Windows/2.6.0Windows is encrypted with a hard-coded cryptographic key, so anyone who knows that key and the algorithm can decrypt it. A low-privilege user could decrypt and modify the backup file in...

7.5CVSS5.8AI score0.01229EPSS
SaveExploits3References2
NVD
NVD
added 2018/05/03 6:29 p.m.26 views

CVE-2018-10167

The web application backup file in the TP-Link EAP Controller and Omada Controller versions 2.5.4Windows/2.6.0Windows is encrypted with a hard-coded cryptographic key, so anyone who knows that key and the algorithm can decrypt it. A low-privilege user could decrypt and modify the backup file in...

7.5CVSS7.3AI score0.01229EPSS
SaveExploits3References2
CVE
CVE
added 2018/05/03 6:00 p.m.59 views

CVE-2018-10167

TP-Link EAP Controller and Omada Controller (Windows) versions 2.5.4_Windows and 2.6.0_Windows are affected by CVE-2018-10167 due to a hard-coded cryptographic key used to encrypt the web app backup file. A low-privilege user can decrypt and modify the backup to escalate privileges, including cre...

7.5CVSS7.5AI score0.01229EPSS
SaveExploits3References2Affected Software1
Cvelist
Cvelist
added 2018/05/03 6:00 p.m.32 views

CVE-2018-10167

The web application backup file in the TP-Link EAP Controller and Omada Controller versions 2.5.4Windows/2.6.0Windows is encrypted with a hard-coded cryptographic key, so anyone who knows that key and the algorithm can decrypt it. A low-privilege user could decrypt and modify the backup file in...

7.6AI score0.01229EPSS
SaveExploits3References2
Packet Storm
Packet Storm
added 2018/05/03 12:00 a.m.67 views

Watchguard Hard-Coded Credentials / Failed Controls

Introduction ============ Multiple vulnerabilities can be chained together in a number of WatchGuard AP products which result in pre-authenticated remote code execution. The vendor has produced a knowledge-base article1 and announcement2 regarding these issues. ZX Security would like to commend t...

8.5AI score0.06483EPSS
SaveExploits6
zdt
zdt
added 2018/05/03 12:00 a.m.71 views

Watchguard Hard-Coded Credentials / Failed Controls Vulnerability

WatchGuard Access Points running firmware before version 1.2.9.15 suffer from hard-coded credential, hidden authentication, file upload, and incorrect validation vulnerabilities. Introduction ============ Multiple vulnerabilities can be chained together in a number of WatchGuard AP products which...

0.1AI score0.06483EPSS
SaveExploits6
ICS
ICS
added 2018/05/03 12:00 a.m.80 views

Philips Brilliance Computed Tomography (CT) System (Update A)

1. EXECUTIVE SUMMARY CVSS v3 8.4 ATTENTION: Low skill level to exploit Vendor: Philips --------- Begin Update A Part 1 of 3 ---------- Equipment: Brilliance CT Scanners and MX8000 Dual EXP --------- End Update A Part 1 of 3 ---------- Vulnerabilities: Execution with Unnecessary Privileges,...

8.8CVSS8.9AI score0.00413EPSS
SaveExploits0References5
NVD
NVD
added 2018/05/01 6:29 p.m.26 views

CVE-2017-14014

Boston Scientific ZOOM LATITUDE PRM Model 3120 uses a hard-coded cryptographic key to encrypt PHI prior to having it transferred to removable media. CVSS v3 base score: 4.6; CVSS vector string: AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N...

4.6CVSS4.7AI score0.00368EPSS
SaveExploits0References2
Prion
Prion
added 2018/05/01 6:29 p.m.14 views

Hardcoded credentials

Boston Scientific ZOOM LATITUDE PRM Model 3120 uses a hard-coded cryptographic key to encrypt PHI prior to having it transferred to removable media. CVSS v3 base score: 4.6; CVSS vector string: AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N...

2.1CVSS4.7AI score0.00368EPSS
SaveExploits0References2
CVE
CVE
added 2018/05/01 6:00 p.m.51 views

CVE-2017-14014

Summary of CVE-2017-14014 : The Boston Scientific ZOOM LATITUDE PRM Model 3120 uses a hard-coded cryptographic key to encrypt PHI before it is transferred to removable media. This creates a vulnerability (CWE-321: Use of Hard-coded Cryptographic Key) with CVSS3 base score 4.6 (vector AV:P/AC:L/PR...

4.6CVSS4.7AI score0.00368EPSS
SaveExploits0References2Affected Software1
OSV
OSV
added 2018/04/24 3:29 p.m.6 views

CVE-2017-9656

The backend database of the Philips DoseWise Portal application versions 1.1.7.333 and 2.1.1.3069 uses hard-coded credentials for a database account with privileges that can affect confidentiality, integrity, and availability of the database. For an attacker to exploit this vulnerability, elevate...

9.1CVSS5.8AI score0.02047EPSS
SaveExploits0References3
ATTACKERKB
ATTACKERKB
added 2018/04/24 3:29 p.m.3 views

CVE-2017-9656

The backend database of the Philips DoseWise Portal application versions 1.1.7.333 and 2.1.1.3069 uses hard-coded credentials for a database account with privileges that can affect confidentiality, integrity, and availability of the database. For an attacker to exploit this vulnerability, elevate...

9.1CVSS5.6AI score0.02047EPSS
SaveExploits0References4Affected Software1
NVD
NVD
added 2018/04/24 3:29 p.m.20 views

CVE-2017-9656

The backend database of the Philips DoseWise Portal application versions 1.1.7.333 and 2.1.1.3069 uses hard-coded credentials for a database account with privileges that can affect confidentiality, integrity, and availability of the database. For an attacker to exploit this vulnerability, elevate...

9.1CVSS9.4AI score0.02047EPSS
SaveExploits0References3
CVE
CVE
added 2018/04/24 3:00 p.m.50 views

CVE-2017-9656

This CVE (CVE-2017-9656) affects Philips DoseWise Portal (DWP) Backend DB credentials in versions 1.1.7.333 and 2.1.1.3069. The root cause is hard-coded credentials in backend system files, granting a database account with privileges that can affect confidentiality, integrity, and availability. E...

9.1CVSS9.2AI score0.02047EPSS
SaveExploits0References3Affected Software1
Cvelist
Cvelist
added 2018/04/24 3:00 p.m.29 views

CVE-2017-9656

The backend database of the Philips DoseWise Portal application versions 1.1.7.333 and 2.1.1.3069 uses hard-coded credentials for a database account with privileges that can affect confidentiality, integrity, and availability of the database. For an attacker to exploit this vulnerability, elevate...

9.4AI score0.02047EPSS
SaveExploits0References3
Microsoft KB
Microsoft KB
added 2018/04/21 5:33 a.m.98 views

Release notes for Windows Server 2003 Service Pack 1

Includes the release notes for Windows Server 2003 Service Pack 1.INTRODUCTIONThis article includes the release notes for Microsoft Windows Server 2003 Service Pack 1 SP1.More InformationThe release notes that are included in this article address late-breaking issues that were not addressed in th...

0.2AI score
SaveExploits0
CNVD
CNVD
added 2018/04/19 12:00 a.m.10 views

Prisma Industriale Checkweigher PrismaWEB Hardcoded Credentials Vulnerability

Prisma Industriale Checkweigher PrismaWEB is a management system for checkweighers from Prisma Italia. A security vulnerability exists in Prisma Industriale Checkweigher PrismaWEB version 1.21. A remote attacker can exploit the vulnerability by reading the file user/scripts/loginpar.js to obtain ...

9.8CVSS7AI score0.31302EPSS
SaveExploits2References1
Rows per page
Query Builder