11722 matches found
CVE-2020-4690
IBM Security Guardium 11.3 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 186697...
IBM Security Guardium Trust Management Vulnerability
IBM Security Guardium is a suite of platforms from IBM USA that provides data protection capabilities. The platform includes features such as custom UI, report management and streamlined audit process building. IBM Security Guardium version 11.3 contains a hard-coded credential vulnerability. An...
Enbra Ewm Trust Management Issue Vulnerability
Enbra Ewm is a universal reading device from the Czech company Enbra. It uses radios to read water meters, heating cost indicators and heat meters. Enbra EWM is vulnerable to a trust management issue, which stems from multiple wireless M-Bus devices from Enbra using hard-coded credentials in secu...
CVE-2021-34571
Multiple Wireless M-Bus devices by Enbra use Hard-coded Credentials in Security mode 5 without an option to change the encryption key. An adversary can learn all information that is available in Enbra EWM...
CVE-2021-34571
Multiple Wireless M-Bus devices by Enbra use Hard-coded Credentials in Security mode 5 without an option to change the encryption key. An adversary can learn all information that is available in Enbra EWM...
CVE-2021-34571
The CVE-2021-34571 entry concerns Enbra EWM, a universal Enbra Wireless M-Bus reading device. Concrete details across connected records show a trust/credential management issue in which several wireless M-Bus devices use hard-coded credentials in secure mode 5, with no option to change the encryp...
CVE-2021-34571 Hard-coded Credentials in Enbra Wireless M-Bus devices
Multiple Wireless M-Bus devices by Enbra use Hard-coded Credentials in Security mode 5 without an option to change the encryption key. An adversary can learn all information that is available in Enbra EWM...
PT-2021-20553
Name of the Vulnerable Software and Affected Versions: Enbra EWM affected versions not specified Description: The issue concerns the use of hard-coded credentials in Security mode 5 of Enbra Wireless M-Bus devices, without the option to change the encryption key. This allows an adversary to acces...
CVE-2021-34571: Use of Hard-coded Credentials
Multiple Wireless M-Bus devices by Enbra use Hard-coded Credentials in Security mode 5 without an option to change the encryption key. An adversary can learn all information that is available in Enbra EWM...
Enbra Ewm Trust Management Vulnerability
Enbra Ewm is a universal reading device from the Czech company Enbra. It uses radios to read water meters, heating cost indicators and heat meters. Enbra EWM is vulnerable to a trust management issue, which stems from multiple wireless M-Bus devices from Enbra using hard-coded credentials in secu...
CVE-2021-28813: Use of Hard-coded Password
A vulnerability involving insecure storage of sensitive information has been reported to affect QSW-M2116P-2T2S and QNAP switches running QuNetSwitch. If exploited, this vulnerability allows remote attackers to read sensitive information by accessing the unrestricted storage mechanism.We have...
CVE-2021-28913
BAB TECHNOLOGIE GmbH eibPort V3 prior version 3.9.1 allow unauthenticated attackers access to /webif/SecurityModule to validate the so called and hard coded unique 'eibPort String' which acts as the root SSH key passphrase. This is usable and part of an attack chain to gain SSH root access...
CVE-2021-28912
BAB TECHNOLOGIE GmbH eibPort V3. Each device has its own unique hard coded and weak root SSH key passphrase known as 'eibPort string'. This is usable and the final part of an attack chain to gain SSH root access...
Hardcoded credentials
BAB TECHNOLOGIE GmbH eibPort V3 prior version 3.9.1 allow unauthenticated attackers access to /webif/SecurityModule to validate the so called and hard coded unique 'eibPort String' which acts as the root SSH key passphrase. This is usable and part of an attack chain to gain SSH root access...
CVE-2021-28912
BAB TECHNOLOGIE GmbH eibPort V3. Each device has its own unique hard coded and weak root SSH key passphrase known as 'eibPort string'. This is usable and the final part of an attack chain to gain SSH root access...
CVE-2021-28912: Weak Password Requirements
BAB TECHNOLOGIE GmbH eibPort V3. Each device has its own unique hard coded and weak root SSH key passphrase known as 'eibPort string'. This is usable and the final part of an attack chain to gain SSH root access...
Mitsubishi Electric Europe B.V. smartRTU and INEA ME-RTU
1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Mitsubishi Electric Europe B.V. Equipment: smartRTU and INEA ME-RTU Vulnerabilities: OS Command Injection, Improper Access Control, Cross-site Scripting, Use of Hard-coded Credentials, Unprotected...
PT-2021-17982
Name of the Vulnerable Software and Affected Versions: BAB TECHNOLOGIE GmbH eibPort V3 Description: The issue concerns a hard-coded and weak root SSH key passphrase, known as 'eibPort string', which is unique to each device. This passphrase can be used to gain SSH root access, representing the...
ECOA Building Automation System Hard-coded Credentials SSH Access
Summary 1 The Risk-Terminator Web Graphic control BEMS Building Energy Management System are designed to provide you with the latest in the Human Machine Interface HMI technology, for completely monitoring and controlling management. It may be used singly for small and medium sized facilities,...
in leantime/leantime
✍️ Description In the source code of the application, the Secret Hash value and the initialization vector is being hardcoded. 🕵️♂️ Proof of Concept In the following code snippet, we can see the hard-coded secret hash and IV. private $encryptionMethod = 'AES-256-CBC'; private $secrethash =...