8391 matches found
CVE-2022-22522
CVE-2022-22522 affects Carlo Gavazzi UWP3.0 and CPY Car Park Server 2.8.3, where a remote, unauthenticated attacker could exploit hard-coded credentials to gain full access to the device. The vulnerability is described as trust/credential management issues enabling authentication bypass and full ...
Carlo Gavazzi UWP 信任管理问题漏洞
Carlo Gavazzi UWP is a monitoring and control Universal Web Platform from Carlo Gavazzi. for applications such as building automation, energy efficiency performance management and parking lot guidance. A trust management issue vulnerability exists in Carlo Gavazzi UWP 3.0, which can be exploited ...
Carlo Gavazzi UWP 信任管理问题漏洞
Carlo Gavazzi UWP is a monitoring and control Universal Web Platform from Carlo Gavazzi. It is used for applications such as building automation, energy efficiency performance management and parking lot guidance. A vulnerability with trust management issues exists in Carlo Gavazzi UWP version 3.0...
PT-2022-19252 · Carlo Gavazzi · Carlo Gavazzi Uwp3.0
Name of the Vulnerable Software and Affected Versions: Carlo Gavazzi UWP3.0 affected versions not specified CPY Car Park Server version 2.8.3 Description: A remote, unauthenticated attacker could use hard-coded credentials to gain SuperUser access to the device. This issue affects multiple versio...
PT-2022-15492 · Carlo Gavazzi · Carlo Gavazzi Uwp3.0
Name of the Vulnerable Software and Affected Versions: Carlo Gavazzi UWP3.0 affected versions not specified CPY Car Park Server version 2.8.3 Description: A remote, unauthenticated attacker could use hard-coded credentials to gain full access to the device. This issue affects Carlo Gavazzi UWP3.0...
CVE-2022-36159
Contec FXA3200 version 1.13 and under were discovered to contain a hard coded hash password for root stored in the component /etc/shadow. As the password strength is weak, it can be cracked in few minutes. Through this credential, a malicious actor can access the Wireless LAN Manager interface an...
CVE-2022-36159
Contec FXA3200 version 1.13 and under were discovered to contain a hard coded hash password for root stored in the component /etc/shadow. As the password strength is weak, it can be cracked in few minutes. Through this credential, a malicious actor can access the Wireless LAN Manager interface an...
Design/Logic Flaw
Contec FXA3200 version 1.13 and under were discovered to contain a hard coded hash password for root stored in the component /etc/shadow. As the password strength is weak, it can be cracked in few minutes. Through this credential, a malicious actor can access the Wireless LAN Manager interface an...
CVE-2022-36159
Contec FXA3200 version 1.13 and under were discovered to contain a hard coded hash password for root stored in the component /etc/shadow. As the password strength is weak, it can be cracked in few minutes. Through this credential, a malicious actor can access the Wireless LAN Manager interface an...
CVE-2022-36159
Contec FXA3200 version 1.13 and under were discovered to contain a hard coded hash password for root stored in the component /etc/shadow. As the password strength is weak, it can be cracked in few minutes. Through this credential, a malicious actor can access the Wireless LAN Manager interface an...
CVE-2022-3214
Delta Industrial Automation's DIAEnergy, an industrial energy management system, is vulnerable to CWE-798, Use of Hard-coded Credentials. Versions prior to 1.9.03.009 have this vulnerability. Executable files could be uploaded to certain directories using hard-coded bearer authorization, allowing...
CVE-2022-3214
Delta Industrial Automation's DIAEnergy, an industrial energy management system, is vulnerable to CWE-798, Use of Hard-coded Credentials. Versions prior to 1.9.03.009 have this vulnerability. Executable files could be uploaded to certain directories using hard-coded bearer authorization, allowing...
CVE-2022-3214
Delta Industrial Automation's DIAEnergy, an industrial energy management system, is vulnerable to CWE-798, Use of Hard-coded Credentials. Versions prior to 1.9.03.009 have this vulnerability. Executable files could be uploaded to certain directories using hard-coded bearer authorization, allowing...
Hardcoded credentials
Delta Industrial Automation's DIAEnergy, an industrial energy management system, is vulnerable to CWE-798, Use of Hard-coded Credentials. Versions prior to 1.9.03.009 have this vulnerability. Executable files could be uploaded to certain directories using hard-coded bearer authorization, allowing...
CVE-2022-3214 Delta Electronics DIAEnergy Use of Hard-coded Credentials
Delta Industrial Automation's DIAEnergy, an industrial energy management system, is vulnerable to CWE-798, Use of Hard-coded Credentials. Versions prior to 1.9.03.009 have this vulnerability. Executable files could be uploaded to certain directories using hard-coded bearer authorization, allowing...
CVE-2022-3214
CVE-2022-3214 affects Delta Electronics DIAEnergie. Vulnerable in DIAEnergie before version 1.9.03.009 due to CWE-798 hard-coded credentials; an unauthenticated attacker could upload executables via a hard-coded bearer authorization, enabling remote code execution. CVSS v3.1 base score 9.8 (Netwo...
CVE-2022-38823
In TOTOLINK T6 V4.1.5cu.709B20210518, there is a hard coded password for root in /etc/shadow.sample...
Hardcoded credentials
In TOTOLINK T6 V4.1.5cu.709B20210518, there is a hard coded password for root in /etc/shadow.sample...
CVE-2022-38823
In TOTOLINK T6 V4.1.5cu.709B20210518, there is a hard coded password for root in /etc/shadow.sample...
CVE-2022-38823
CVE-2022-38823 affects TOTOLINK T6 V4.1.5cu.709_B20210518, where a hard-coded root password is stored in /etc/shadow.sample. The vulnerability is described consistently across NVD, Red Hat, CVE feeds, and CNVD references, indicating a high-severity issue with CVSS 3.1 base score 9.8 (NETWORK atta...