Lucene search
+L

5931 matches found

Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2023/09/07 12:00 a.m.•4 views

CVE-2023-39421: Use of Hard-coded Credentials

The RDPWin.dll component as used in the IRM Next Generation booking engine includes a set of hardcoded API keys for third-party services such as Twilio and Vonage. These keys allow unrestricted interaction with these services...

7.7CVSS7.3AI score0.00474EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2023/09/07 12:00 a.m.•7 views

CVE-2023-39422: Use of Hard-coded Credentials

The /irmdata/api/ endpoints exposed by the IRM Next Generation booking engine authenticates requests using HMAC tokens. These tokens are however exposed in a JavaScript file loaded on the client side, thus rendering this extra safety mechanism useless...

9.8CVSS8.2AI score0.00418EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2023/09/07 12:00 a.m.•4 views

CVE-2023-39420: Use of Hard-coded Credentials

The RDPCore.dll component as used in the IRM Next Generation booking engine, allows a remote user to connect to customers with an "admin" account and a corresponding password computed daily by a routine inside the DLL file. Once reverse-engineered, this routine can help an attacker generate the...

9.9CVSS7.8AI score0.00734EPSS
SaveExploits0References2
NVD
NVD
•added 2023/09/06 10:15 a.m.•38 views

CVE-2023-32619

Archer C50 firmware versions prior to 'Archer C50JPV3230505' and Archer C55 firmware versions prior to 'Archer C55JPV1230506' use hard-coded credentials to login to the affected device, which may allow a network-adjacent unauthenticated attacker to execute an arbitrary OS command...

8.8CVSS8.8AI score0.00403EPSS
SaveExploits0References3
osv_cve
osv_cve
•added 2023/09/06 10:15 a.m.•20 views

CVE-2023-32619

Archer C50 firmware versions prior to 'Archer C50JPV3230505' and Archer C55 firmware versions prior to 'Archer C55JPV1230506' use hard-coded credentials to login to the affected device, which may allow a network-adjacent unauthenticated attacker to execute an arbitrary OS command...

8.8CVSS5.9AI score0.00403EPSS
SaveExploits0References3
Cvelist
Cvelist
•added 2023/09/06 9:27 a.m.•48 views

CVE-2023-32619

Archer C50 firmware versions prior to 'Archer C50JPV3230505' and Archer C55 firmware versions prior to 'Archer C55JPV1230506' use hard-coded credentials to login to the affected device, which may allow a network-adjacent unauthenticated attacker to execute an arbitrary OS command...

9AI score0.00403EPSS
SaveExploits0References3
Vulnrichment
Vulnrichment
•added 2023/09/06 9:27 a.m.•20 views

CVE-2023-32619

Archer C50 firmware versions prior to 'Archer C50JPV3230505' and Archer C55 firmware versions prior to 'Archer C55JPV1230506' use hard-coded credentials to login to the affected device, which may allow a network-adjacent unauthenticated attacker to execute an arbitrary OS command...

7.4AI score0.00403EPSS
SaveExploits0References3
CVE
CVE
•added 2023/09/06 9:27 a.m.•107 views

CVE-2023-32619

CVE-2023-32619 affects TP‑LINK Archer C50 and C55 devices with JP firmware releases prior to C50_V3_230505 and C55_V1_230506, where hard-coded credentials enable a network‑adjacent, unauthenticated attacker to execute arbitrary OS commands. Root cause: hard-coded login credentials in affected fir...

8.8CVSS8.7AI score0.00403EPSS
SaveExploits0References3Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2023/09/06 12:00 a.m.•8 views

CVE-2023-32619: Use of Hard-coded Credentials

Archer C50 firmware versions prior to 'Archer C50JPV3230505' and Archer C55 firmware versions prior to 'Archer C55JPV1230506' use hard-coded credentials to login to the affected device, which may allow a network-adjacent unauthenticated attacker to execute an arbitrary OS command...

8.8CVSS8.1AI score0.00403EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2023/09/06 12:00 a.m.•16 views

PT-2023-23914 · Tp Link · Archer C55 +1

Name of the Vulnerable Software and Affected Versions: Archer C50 versions prior to Archer C50JP V3 230505 Archer C55 versions prior to Archer C55JP V1 230506 Description: The affected devices use hard-coded credentials to login, which may allow a network-adjacent unauthenticated attacker to...

8.8CVSS7.8AI score0.00403EPSS
SaveExploits0References9
ICS
ICS
•added 2023/09/05 6:00 a.m.•43 views

Fujitsu Limited Real-time Video Transmission Gear "IP series"

1. EXECUTIVE SUMMARY CVSS v3 5.9 ATTENTION: Exploitable remotely Vendor: Fujitsu Limited Equipment: Real-time Video Transmission Gear "IP series" Vulnerability: Use Of Hard-Coded Credentials 2. RISK EVALUATION Successful exploitation of this vulnerability could result in an attacker logging into...

7.5CVSS7.7AI score0.03722EPSS
SaveExploits0References9
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2023/09/05 12:00 a.m.•2 views

CVE-2023-41508: Use of Hard-coded Credentials

A hard coded password in Super Store Finder v3.6 allows attackers to access the administration panel...

9.8CVSS8.2AI score0.01392EPSS
SaveExploits1References2
NVD
NVD
•added 2023/08/31 4:15 p.m.•34 views

CVE-2023-31173

Use of Hard-coded Credentials vulnerability in Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator on Windows allows Authentication Bypass. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before...

8.4CVSS8AI score0.0021EPSS
SaveExploits0References2
osv_cve
osv_cve
•added 2023/08/31 4:15 p.m.•18 views

CVE-2023-31173

Use of Hard-coded Credentials vulnerability in Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator on Windows allows Authentication Bypass. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before...

8.4CVSS5.8AI score0.0021EPSS
SaveExploits0References2
Prion
Prion
•added 2023/08/31 4:15 p.m.•35 views

Hardcoded credentials

Use of Hard-coded Credentials vulnerability in Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator on Windows allows Authentication Bypass. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before...

4.6CVSS8.4AI score0.0021EPSS
SaveExploits0References2Affected Software1
CVE
CVE
•added 2023/08/31 3:30 p.m.•68 views

CVE-2023-31173

CVE-2023-31173 affects Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator for Windows, with the root cause identified as hard-coded credentials that enable authentication bypass. The issue applies to versions before 4.5.0.20. According to the connected sources, the vulnerability i...

8.4CVSS8.1AI score0.0021EPSS
SaveExploits0References2Affected Software1
CNNVD
CNNVD
•added 2023/08/31 12:00 a.m.•16 views

Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator 信任管理问题漏洞

Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator is a freely distributed software tool from Schweitzer Engineering Laboratories, Inc. --- Grid Configurator allows engineers and technicians to quickly create, manage and deploy settings for SEL power system equipment. A security...

8.4CVSS7.8AI score0.0021EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2023/08/31 12:00 a.m.•6 views

CVE-2023-31173: Use of Hard-coded Credentials

Use of Hard-coded Credentials vulnerability in Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator on Windows allows Authentication Bypass. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before...

8.4CVSS7.7AI score0.0021EPSS
SaveExploits0References3
Positive Technologies
Positive Technologies
•added 2023/08/31 12:00 a.m.•15 views

PT-2023-5227 · Schweitzer Engineering Laboratories · Sel-5037 Sel Grid Configurator

Name of the Vulnerable Software and Affected Versions: Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator versions prior to 4.5.0.20 Description: The issue is related to the use of hard-coded credentials in the SEL-5037 SEL Grid Configurator, which allows authentication bypass. Fo...

8.4CVSS8.3AI score0.0021EPSS
SaveExploits0References6
osv_cve
osv_cve
•added 2023/08/28 4:15 a.m.•13 views

CVE-2023-38026

SpotCam Co., Ltd. SpotCam FHD 2 has a vulnerability of using hard-coded uBoot credentials. An remote attacker can exploit this vulnerability to access the system to perform arbitrary system operations or disrupt service...

9.8CVSS5.9AI score0.00822EPSS
SaveExploits0References1
Rows per page