1175 matches found
HP SAN/iQ Virtual SAN Appliance Multiple Parameters Command Execution Vulnerabilities
HP SAN/iQ Virtual SAN Appliance is prone to multiple command execution vulnerabilities. SPDX-FileCopyrightText: 2012 Greenbone AG Some text descriptions might be excerpted from a referenced sources, and are Copyright C by the respective right holders. SPDX-License-Identifier: GPL-2.0-only...
Siemens Simatic S7-300 - PLC Remote Memory Viewer (Metasploit)
Siemens Simatic S7-300 - PLC Remote Memory Viewer Metasploit Exploit Title: Siemens Simatic S7 300 Remote Memory Viewer Backdoor Date: 7-13-2012 Exploit Author: Dillon Beresford Vendor Homepage: http://www.siemens.com/ Tested on: Siemens Simatic S7-1200 PLC CVE : None require 'msf/core' class...
ZTE(ZTE)the phone there the back door, get a Root Shell-vulnerability warning-the black bar safety net
It's appearing that a root virus has appeared in ZTE phones, allowing full root to devices. It simply provides a root shell using a hard-coded password. This is serious news for any hackers, as this command can cause major damage to phones. Here is the information, should you wish to have a go: T...
CVE-2010-4965
/etc/rc.d/rc.local on the D-Link DCS-2121 camera with firmware 1.04 configures a hardcoded password of admin for the root account, which makes it easier for remote attackers to obtain shell access by leveraging a running telnetd server...
VulnCheck KEV: CVE-2010-2772
Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568...
CVE-2010-2772
CVE-2010-2772 affects Siemens SIMATIC WinCC and SIMATIC PCS 7: a security bypass via default hard-coded SQL credentials allows remote attackers to access the backend database with administrative-like access. The vulnerability is tied to use of default credentials in the WinCC SQL server, permitti...
CVE-2010-2772
Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568...
CVE-2010-2772
Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568...
Hardcoded credentials
Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568...
PT-2010-4286
Name of the Vulnerable Software and Affected Versions Siemens Simatic WinCC and PCS 7 SCADA system affected versions not specified Description The issue concerns a hard-coded password in the system, allowing local users to access a back-end database and gain privileges. This has been demonstrated...
CVE-2010-2772
Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568. Recent assessments: Assessed Attacker...
CVE-2009-4781
TUKEVA Password Reminder before 1.0.0.4 uses a hard-coded password for rem.accdb, which allows local users to discover credentials via a DBI connection...
CVE-2009-4781
TUKEVA Password Reminder (before version 1.0.0.4) stores a hard-coded password for rem.accdb, enabling local users to discover credentials via a DBI connection. Affected: TUKEVA Password Reminder
CVE-2009-4781
TUKEVA Password Reminder before 1.0.0.4 uses a hard-coded password for rem.accdb, which allows local users to discover credentials via a DBI connection...
PT-2010-1590 · Tukeva · Tukeva Password Reminder
Name of the Vulnerable Software and Affected Versions: TUKEVA Password Reminder version 1.0.0.3 and earlier Description: The issue allows local users to discover credentials due to a hard-coded password for rem.accdb. This can be achieved via a DBI connection. Recommendations: For versions prior ...
TEKUVA Authentication Bypass
!/usr/bin/perl Exploit: TEKUVA Password Reminder Authentication Bypass Date: 11/19/2009 Author: iqlusion [email protected] Software Link: http://download.cnet.com/Password-Reminder/3000-20644-10966598.html Version: 1.0.0.1 Info: TEKUVA Password Reminder is a password vault that allows you to...
Riorey RIOS 4.7.0 - Hard-Coded Password
Riorey RIOS 4.7.0 - Hard-Coded Password Severity: High Full root access to the device Date: 07 October 2009 Versions Affected: RIOS 4.6.6 , 4.7.0 possibly others Discovered on: 25 July 2009 Vendor URL: www.riorey.com Author: Marek Kroemeke Overview: Riorey DDoS mitigation appliences www.riorey.co...
CVE-2008-1160
ZyXEL ZyWALL 1050 is affected by CVE-2008-1160 due to a hard-coded default password for the Quagga/Zebra routing daemons. The vulnerability allows remote attackers to gain privileges by authenticating with the default credentials (password: zebra) on Quagga/RIP ports 2601 and 2602 and Quagga/OSPF...
CVE-2008-1160
ZyXEL ZyWALL 1050 has a hard-coded password for the Quagga and Zebra processes that is not changed when it is set by a user, which allows remote attackers to gain privileges...
PT-2008-1001 · Zyxel +1 · Zywall Usg 300 +3
Name of the Vulnerable Software and Affected Versions: ZyXEL ZyWALL 1050 affected versions not specified ZyXEL ZyWALL USG 300 affected versions not specified Description: The issue is related to a hard-coded password for the Quagga and Zebra processes in the ZyXEL ZyWALL firewall/router operating...