8304 matches found
Design/Logic Flaw
Contec FXA3200 version 1.13 and under were discovered to contain a hard coded hash password for root stored in the component /etc/shadow. As the password strength is weak, it can be cracked in few minutes. Through this credential, a malicious actor can access the Wireless LAN Manager interface an...
CVE-2022-36159
Contec FXA3200 version 1.13 and under were discovered to contain a hard coded hash password for root stored in the component /etc/shadow. As the password strength is weak, it can be cracked in few minutes. Through this credential, a malicious actor can access the Wireless LAN Manager interface an...
CVE-2022-36159
Contec FXA3200 version 1.13 and under were discovered to contain a hard coded hash password for root stored in the component /etc/shadow. As the password strength is weak, it can be cracked in few minutes. Through this credential, a malicious actor can access the Wireless LAN Manager interface an...
CVE-2022-3214
Delta Industrial Automation's DIAEnergy, an industrial energy management system, is vulnerable to CWE-798, Use of Hard-coded Credentials. Versions prior to 1.9.03.009 have this vulnerability. Executable files could be uploaded to certain directories using hard-coded bearer authorization, allowing...
CVE-2022-3214
Delta Industrial Automation's DIAEnergy, an industrial energy management system, is vulnerable to CWE-798, Use of Hard-coded Credentials. Versions prior to 1.9.03.009 have this vulnerability. Executable files could be uploaded to certain directories using hard-coded bearer authorization, allowing...
CVE-2022-3214
Delta Industrial Automation's DIAEnergy, an industrial energy management system, is vulnerable to CWE-798, Use of Hard-coded Credentials. Versions prior to 1.9.03.009 have this vulnerability. Executable files could be uploaded to certain directories using hard-coded bearer authorization, allowing...
Hardcoded credentials
Delta Industrial Automation's DIAEnergy, an industrial energy management system, is vulnerable to CWE-798, Use of Hard-coded Credentials. Versions prior to 1.9.03.009 have this vulnerability. Executable files could be uploaded to certain directories using hard-coded bearer authorization, allowing...
CVE-2022-3214 Delta Electronics DIAEnergy Use of Hard-coded Credentials
Delta Industrial Automation's DIAEnergy, an industrial energy management system, is vulnerable to CWE-798, Use of Hard-coded Credentials. Versions prior to 1.9.03.009 have this vulnerability. Executable files could be uploaded to certain directories using hard-coded bearer authorization, allowing...
CVE-2022-3214
CVE-2022-3214 affects Delta Electronics DIAEnergie. Vulnerable in DIAEnergie before version 1.9.03.009 due to CWE-798 hard-coded credentials; an unauthenticated attacker could upload executables via a hard-coded bearer authorization, enabling remote code execution. CVSS v3.1 base score 9.8 (Netwo...
CVE-2022-38823
In TOTOLINK T6 V4.1.5cu.709B20210518, there is a hard coded password for root in /etc/shadow.sample...
Hardcoded credentials
In TOTOLINK T6 V4.1.5cu.709B20210518, there is a hard coded password for root in /etc/shadow.sample...
CVE-2022-38823
In TOTOLINK T6 V4.1.5cu.709B20210518, there is a hard coded password for root in /etc/shadow.sample...
CVE-2022-38823
CVE-2022-38823 affects TOTOLINK T6 V4.1.5cu.709_B20210518, where a hard-coded root password is stored in /etc/shadow.sample. The vulnerability is described consistently across NVD, Red Hat, CVE feeds, and CNVD references, indicating a high-severity issue with CVSS 3.1 base score 9.8 (NETWORK atta...
PT-2022-6643 · Unknown · Diaenergie
Name of the Vulnerable Software and Affected Versions: DIAEnergie versions prior to 1.9.03.009 Description: The issue is related to the use of hard-coded credentials in the DIAEnergie industrial energy management system. This allows a remote attacker to execute arbitrary code by uploading...
Exploit for Use of Hard-coded Credentials in Automationanywhere Automation_360
CVE-2022-29856-PoC Minimal...
PT-2022-23237 · Contec · Contec Fxa3200
Name of the Vulnerable Software and Affected Versions: Contec FXA3200 versions 1.13 and under Description: The issue concerns a hard-coded hash password for the root user stored in the /etc/shadow component. This password is weak and can be cracked in a few minutes. Once the password is obtained,...
CVE-2022-38394
Use of hard-coded credentials for the telnet server of CentreCOM AR260S V2 firmware versions prior to Ver.3.3.7 allows a remote unauthenticated attacker to execute an arbitrary OS command...
CVE-2022-38394
Use of hard-coded credentials for the telnet server of CentreCOM AR260S V2 firmware versions prior to Ver.3.3.7 allows a remote unauthenticated attacker to execute an arbitrary OS command...