8277 matches found
CVE-2024-35338
CVE-2024-35338 affects Tenda i29V1.0 V1.0.0.5 with a hardcoded root password, enabling authentication bypass. Multiple sources corroborate the root-password issue; CVSS v3.1 base score is 9.8 (CRITICAL). Exploitation details are not provided in the documents; no remediation steps are specified he...
D-Link DAP-1360 Hardcoded Authentication Bypass Vulnerability
The D-Link DAP-1360 is a router from China-based AUO D-Link. The D-Link DAP-1360 suffers from a hard-coded authentication bypass vulnerability that can be exploited by an attacker to bypass authentication...
D-Link DAP-2622 Hardcoded Credential Authentication Bypass Vulnerability
The D-Link DAP-2622 is a wireless access point AP from D-Link designed for wireless network coverage in an enterprise or commercial environment. The D-Link DAP-2622 suffers from a hard-coded credential authentication bypass vulnerability that originates from the Telnet command line interface usin...
The vulnerability of the installation file initSetup_v2.0.sh, a configuration migration tool for Expedition, allows a perpetrator to gain increased privileges.
The vulnerability of the initSetupv2.0.sh file, a configuration migration tool for Expedition, lies in the use of hard-coded credentials. Exploiting this vulnerability could allow an attacker to gain increased privileges remotely...
LumisXP 16.1.x Hardcoded Credentials / IDOR
===== Tempest Security Intelligence - ADV-6/2024 ========================== LumisXP v15.0.x to v16.1.x Author: Rodolfo Tavares Tempest Security Intelligence - Recife, Pernambuco - Brazil ===== Table of Contents================================================== Overview Detailed description Timeli...
Siemens Mendix Encryption Module Hardcoded Default Encryption Key Vulnerability
The Mendix Encryption module takes care of the following encryption requirements: plain text encryption e.g. passwords and FileDocument encryption e.g. documents or photos. A hard-coded default encryption key vulnerability exists in the Siemens Mendix Encryption module, which can be exploited by ...
CVE-2024-28747
An unauthenticated remote attacker can use the hard-coded credentials to access the SmartSPS devices with high privileges...
CVE-2024-28747 ifm: Use of Hard-coded Credentials
An unauthenticated remote attacker can use the hard-coded credentials to access the SmartSPS devices with high privileges...
CVE-2024-28747 ifm: Use of Hard-coded Credentials
An unauthenticated remote attacker can use the hard-coded credentials to access the SmartSPS devices with high privileges...
CVE-2024-28747
CVE-2024-28747 affects SmartSPS devices (ifm electronic) with unauthenticated remote access via hard-coded credentials, enabling high-privilege control. Multiple sources describe the issue as a trust/credential management problem enabling remote, unauthenticated access to SmartSPS devices. The NV...
ZKTeco ZKBio CVSecurity Security Breach
ZKTeco ZKBio CVSecurity is a series of biometric solutions from the Chinese company ZKTeco. A security vulnerability exists in ZKTeco ZKBio CVSecurity version v6.1.1, which stems from the presence of hard-coded encryption keys...
PT-2024-22555 · Smartsps · Smartsps
Name of the Vulnerable Software and Affected Versions: SmartSPS devices affected versions not specified Description: An unauthenticated remote attacker can use the hard-coded credentials to access the SmartSPS devices with high privileges. Recommendations: At the moment, there is no information...
ifm electronic Smart PLC AC14xx and ifm electronic Smart PLC AC4xxS Trust Management Issue Vulnerability
The ifm electronic Smart PLC AC14xx and ifm electronic Smart PLC AC4xxS are both a series of hosts/gateways from ifm electronic Germany. A trust management issue vulnerability exists in ifm electronic Smart PLC AC14xx and ifm electronic Smart PLC AC4xxS versions 4.3.17 and earlier, which originat...
PT-2024-8753 · Mendix · Mendix Encryption
Name of the Vulnerable Software and Affected Versions: Mendix Encryption versions 10.0.0 through 10.0.1 Description: A vulnerability has been identified in the Mendix Encryption module, where affected versions define a specific hard-coded default value for the EncryptionKey constant. This default...
Siemens Mendix Encryption Module
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories CERT Services | Services |...
Siemens Mendix 安全漏洞
The Mendix Encryption module takes care of the following encryption requirements: plain text encryption e.g. passwords and FileDocument encryption e.g. documents or photos. A hard-coded default encryption key vulnerability exists in the Siemens Mendix Encryption module, which can be exploited by ...
ifm electronic Smart PLC AC14xx and Smart PLC AC4xxS Trust Management Issue Vulnerability
The ifm electronic Smart PLC AC14xx and ifm electronic Smart PLC AC4xxS are both a series of hosts/gateways from ifm electronic Germany. A trust management issue vulnerability exists in ifm electronic Smart PLC AC14xx and Smart PLC AC4xxS versions 4.3.17 and earlier, which originates from an...
CVE-2023-46685
A hard-coded password vulnerability exists in the telnetd functionality of LevelOne WBR-6013 RER4Av3411b2T2RLEV09170623. A set of specially crafted network packets can lead to arbitrary command execution...
CVE-2023-46685
A hard-coded password vulnerability exists in the telnetd functionality of LevelOne WBR-6013 RER4Av3411b2T2RLEV09170623. A set of specially crafted network packets can lead to arbitrary command execution...
CVE-2023-46685
A hard-coded password vulnerability exists in the telnetd functionality of LevelOne WBR-6013 RER4Av3411b2T2RLEV09170623. A set of specially crafted network packets can lead to arbitrary command execution...