491 matches found
SUSE CVE-2017-5857
Memory leak in the virglcmdresourceunref function in hw/display/virtio-gpu-3d.c in QEMU aka Quick Emulator allows local guest OS users to cause a denial of service host memory consumption via a large number of VIRTIOGPUCMDRESOURCEUNREF commands sent without detaching the backing storage beforehan...
SUSE CVE-2018-1059
The DPDK vhost-user interface does not check to verify that all the requested guest physical range is mapped and contiguous when performing Guest Physical Addresses to Host Virtual Addresses translations. This may lead to a malicious guest exposing vhost-user backend process memory. All versions...
SUSE CVE-2021-3593
An invalid pointer initialization issue was found in the SLiRP networking implementation of QEMU. The flaw exists in the udp6input function and could occur while processing a udp packet that is smaller than the size of the 'udphdr' structure. This issue may lead to out-of-bounds read access or...
SUSE CVE-2021-28696
IOMMU page mapping issues on x86 This CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE. Both AMD and Intel allow ACPI tables to specify regions of memory which should be left untranslated, which typically means these addresse...
SUSE CVE-2021-28706
guests may exceed their designated memory limit When a guest is permitted to have close to 16TiB of memory, it may be able to issue hypercalls to increase its memory allocation beyond the administrator established limit. This is a result of a calculation done with 32-bit precision, which may...
SUSE CVE-2021-28705
issues with partially successful P2M updates on x86 This CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE. x86 HVM and PVH guests may be started in populate-on-demand PoD mode, to provide a way for them to later easily have...
SUSE CVE-2022-23040
Linux PV device frontends vulnerable to attacks by backends This CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE. Several Linux PV device frontends are using the grant table interfaces for removing access rights of the...
SUSE CVE-2022-42319
Xenstore: Guests can cause Xenstore to not free temporary memory When working on a request of a guest, xenstored might need to allocate quite large amounts of memory temporarily. This memory is freed only after the request has been finished completely. A request is regarded to be finished only...
CVE-2022-23814
Failure to validate addresses provided by software to BIOS commands may result in a potential loss of integrity of guest memory in a confidential compute environment. Mitigation Please contact AMD for more updates on this flaw...
CVE-2022-23813
The software interfaces to ASP and SMU may not enforce the SNP memory security policy resulting in a potential loss of integrity of guest memory in a confidential compute environment. Mitigation Please contact AMD for more updates on this flaw...
CVE-2022-23813
The software interfaces to ASP and SMU may not enforce the SNP memory security policy resulting in a potential loss of integrity of guest memory in a confidential compute environment...
CVE-2022-23813
The software interfaces to ASP and SMU may not enforce the SNP memory security policy resulting in a potential loss of integrity of guest memory in a confidential compute environment...
CVE-2022-23814
Failure to validate addresses provided by software to BIOS commands may result in a potential loss of integrity of guest memory in a confidential compute environment...
CVE-2022-23814
Failure to validate addresses provided by software to BIOS commands may result in a potential loss of integrity of guest memory in a confidential compute environment...
Design/Logic Flaw
The software interfaces to ASP and SMU may not enforce the SNP memory security policy resulting in a potential loss of integrity of guest memory in a confidential compute environment...
Authorization
Failure to validate addresses provided by software to BIOS commands may result in a potential loss of integrity of guest memory in a confidential compute environment...
CVE-2022-23814
Failure to validate addresses provided by software to BIOS commands may result in a potential loss of integrity of guest memory in a confidential compute environment...
CVE-2022-23813
CVE-2022-23813 involves AMD ASP/SMU where the interface between ASP and SMU may fail to enforce SNP memory security policy, risking loss of integrity of SNP-protected guest memory in confidential Compute (AMD EPYC). Affected: ASP/SMU components across generations; Root cause: inadequate enforceme...
CVE-2022-23813
The software interfaces to ASP and SMU may not enforce the SNP memory security policy resulting in a potential loss of integrity of guest memory in a confidential compute environment...
PT-2023-1482 · Amd · Amd System Management Unit +1
Name of the Vulnerable Software and Affected Versions: AMD Secure Processor ASP and System Management Unit SMU affected versions not specified Description: The issue is related to the software interfaces of ASP and SMU, which may not properly enforce the SNP memory security policy. This could lea...