Lucene search
+L

3195 matches found

hivepro
hivepro
added 2023/09/20 9:26 a.m.24 views

Redfly Targets Critical Infrastructure in Asia with ShadowPad Trojan

Threat Level Attack Report For a detailed threat advisory, download the pdf file here Summary Redfly, an espionage group, targeted Asian critical infrastructure, compromising a national grid for six months using ShadowPad. This underscores a rising trend in such attacks, raising global concerns...

7AI score
SaveExploits0
BDU FSTEC
BDU FSTEC
added 2023/09/19 12:00 a.m.11 views

The vulnerability of the SEL-5037 SEL Grid Configurator software in terms of creating, managing, and deploying energy systems allows a hacker to perform a CSRF attack due to insufficient verification of the authenticity of the executed requests.

The vulnerability of the SEL-5037 SEL Grid Configurator software, which is used for creating, managing, and deploying energy systems, stems from insufficient verification of the authenticity of the requests being made. Exploiting this vulnerability could allow a malicious actor to carry out a CSR...

7.8CVSS6.5AI score0.00204EPSS
SaveExploits0References3Affected Software1
BDU FSTEC
BDU FSTEC
added 2023/09/19 12:00 a.m.9 views

The vulnerability of the SEL-5037 SEL Grid Configurator software in terms of creating, managing, and deploying energy systems lies in its use of rigidly encrypted credentials. This allows a malicious individual to bypass authentication processes.

The vulnerability of the SEL-5037 SEL Grid Configurator software for creating, managing, and deploying energy systems lies in the use of rigidly encrypted credentials. Exploiting this vulnerability could allow an attacker to bypass authentication processes...

8.4CVSS7.5AI score0.00199EPSS
SaveExploits0References3Affected Software1
The Hacker News
The Hacker News
added 2023/09/12 10:18 a.m.98 views

Chinese Redfly Group Compromised a Nation's Critical Grid in 6-Month ShadowPad Campaign

A threat actor called Redfly has been linked to a compromise of a national grid located in an unnamed Asian country for as long as six months earlier this year using a known malware referred to as ShadowPad. "The attackers managed to steal credentials and compromise multiple computers on the...

7.7AI score
SaveExploits0
Wired Threat Level
Wired Threat Level
added 2023/09/12 10:00 a.m.30 views

China-Linked Hackers Breached a Power Grid—Again

Signs suggest the culprits worked within a notorious Chinese hacker group that may have also hacked Indian electric utilities years earlier...

7AI score
SaveExploits0
BDU FSTEC
BDU FSTEC
added 2023/09/08 12:00 a.m.10 views

The vulnerability of the SEL-5037 SEL Grid Configurator software in terms of creating, managing, and deploying energy systems allows a perpetrator to execute arbitrary code with administrative privileges. This vulnerability is related to errors in privilege management.

The vulnerability of the SEL-5037 SEL Grid Configurator software in terms of creating, managing, and deploying energy systems is related to errors in privilege management. Exploiting this vulnerability could allow a malicious actor to execute arbitrary code with administrative privileges...

10CVSS8.4AI score0.00422EPSS
SaveExploits0References3Affected Software1
Patchstack
Patchstack
added 2023/09/01 12:00 a.m.13 views

WordPress Responsive Gallery Grid Plugin <= 2.3.13 is vulnerable to Cross Site Request Forgery (CSRF)

Software Responsive Gallery Grid Type Plugin Vulnerable versions = 2.3.13 Fixed in 2.3.14 OWASP Top 10 A5: Broken Access Control Classification Cross Site Request Forgery CSRF CVE CVE-2023-41659 Patch priority Low CVSS severity Low 5.4 Developer Claim ownership PSID f625c8937bf3 Credits Rio...

8.8CVSS6.6AI score0.00208EPSS
SaveExploits0References2Affected Software1
OSV
OSV
added 2023/08/31 4:15 p.m.12 views

CVE-2023-34392

A Missing Authentication for Critical Function vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run arbitrary commands on managed devices by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated...

8.8CVSS5.9AI score0.00454EPSS
SaveExploits0References2
NVD
NVD
added 2023/08/31 4:15 p.m.28 views

CVE-2023-31174

A Cross-Site Request Forgery CSRF vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more...

7.4CVSS7.4AI score0.00204EPSS
SaveExploits0References2
NVD
NVD
added 2023/08/31 4:15 p.m.32 views

CVE-2023-31175

An Execution with Unnecessary Privileges vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run system commands with the highest level privilege on the system. See Instruction Manual Appendix A and Appendix E dated 20230615 for more...

9.8CVSS9.2AI score0.00422EPSS
SaveExploits0References2
OSV
OSV
added 2023/08/31 4:15 p.m.11 views

CVE-2023-31175

An Execution with Unnecessary Privileges vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run system commands with the highest level privilege on the system. See Instruction Manual Appendix A and Appendix E dated 20230615 for more...

9.8CVSS5.9AI score0.00422EPSS
SaveExploits0References2
OSV
OSV
added 2023/08/31 4:15 p.m.8 views

CVE-2023-31174

A Cross-Site Request Forgery CSRF vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more...

6.5CVSS5.8AI score0.00204EPSS
SaveExploits0References2
OSV
OSV
added 2023/08/31 4:15 p.m.10 views

CVE-2023-31173

Use of Hard-coded Credentials vulnerability in Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator on Windows allows Authentication Bypass. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before...

8.4CVSS5.8AI score0.00199EPSS
SaveExploits0References2
NVD
NVD
added 2023/08/31 4:15 p.m.26 views

CVE-2023-31173

Use of Hard-coded Credentials vulnerability in Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator on Windows allows Authentication Bypass. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before...

8.4CVSS8AI score0.00199EPSS
SaveExploits0References2
Prion
Prion
added 2023/08/31 4:15 p.m.24 views

Hardcoded credentials

Use of Hard-coded Credentials vulnerability in Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator on Windows allows Authentication Bypass. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before...

4.6CVSS8.4AI score0.00199EPSS
SaveExploits0References2Affected Software1
Prion
Prion
added 2023/08/31 4:15 p.m.30 views

Authentication flaw

A Missing Authentication for Critical Function vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run arbitrary commands on managed devices by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated...

6.8CVSS8.8AI score0.00454EPSS
SaveExploits0References2Affected Software1
Prion
Prion
added 2023/08/31 4:15 p.m.33 views

Design/Logic Flaw

An Execution with Unnecessary Privileges vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run system commands with the highest level privilege on the system. See Instruction Manual Appendix A and Appendix E dated 20230615 for more...

7.5CVSS9.5AI score0.00422EPSS
SaveExploits0References2Affected Software1
Prion
Prion
added 2023/08/31 4:15 p.m.25 views

Cross site request forgery (csrf)

A Cross-Site Request Forgery CSRF vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more...

4.3CVSS6.6AI score0.00204EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
added 2023/08/31 3:31 p.m.43 views

CVE-2023-34392 Missing Authentication for Critical Function

A Missing Authentication for Critical Function vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run arbitrary commands on managed devices by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated...

8.2CVSS9.1AI score0.00454EPSS
SaveExploits0References2
CVE
CVE
added 2023/08/31 3:31 p.m.48 views

CVE-2023-34392

The CVE-2023-34392 entry describes a Missing Authentication for Critical Function flaw in Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator, enabling an attacker to execute arbitrary commands on managed devices via an authorized operator. Affected software is SEL-5037 Grid Config...

8.8CVSS8.7AI score0.00454EPSS
SaveExploits0References2Affected Software1
Rows per page
Query Builder