934 matches found
Qualcomm 芯片代码问题漏洞
A Qualcomm chip is a chip from Qualcomm Incorporated USA. A way to miniaturize circuits including primarily semiconductor devices, but also passive components, etc. and is manufactured from time to time on the surface of semiconductor wafers. A code issue vulnerability exists in multiple Qualcomm...
The vulnerability of the libsal.so file in Zyxel GS1900 series switch software allows a hacker to execute arbitrary commands.
The vulnerability of the libsal.so file in Zyxel GS1900 series switch software lies in the lack of measures taken to neutralize special elements. Exploiting this vulnerability allows an attacker to execute arbitrary OS commands through the graphical interface...
The vulnerability of the TFTP-client software for Zyxel GS1900 and XGS1210 series switch devices allows a intruder to execute arbitrary commands.
The vulnerability of the TFTP-client software for Zyxel GS1900 and XGS1210 series switch devices is related to the lack of measures taken to neutralize special elements. Exploiting this vulnerability allows a malicious actor to execute arbitrary OS commands via the graphical interface...
CVE-2021-22823
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector dc.exe V15.0.0.21320...
CVE-2021-22824
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on user-supplied data from a constructed message received on the network. Affected Product: Interactive Graphical SCADA System Data Collector dc.exe...
CVE-2021-22803
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could lead to remote code execution through a number of paths, when an attacker, writes arbitrary files to folders in context of the DC module, by sending constructed messages on the network. Affected Product:...
CVE-2021-22823
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector dc.exe V15.0.0.21320...
CVE-2021-22803
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could lead to remote code execution through a number of paths, when an attacker, writes arbitrary files to folders in context of the DC module, by sending constructed messages on the network. Affected Product:...
CVE-2021-22802
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution due to missing length check on user supplied data, when a constructed message is received on the network. Affected Product: Interactive Graphical SCADA System Data Collector dc.ex...
Design/Logic Flaw
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could lead to remote code execution through a number of paths, when an attacker, writes arbitrary files to folders in context of the DC module, by sending constructed messages on the network. Affected Product:...
Design/Logic Flaw
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause disclosure of arbitrary files being read in the context of the user running IGSS, due to missing validation of user supplied data in network messages. Affected Product: Interactive Graphica...
Remote code execution
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution due to missing length check on user supplied data, when a constructed message is received on the network. Affected Product: Interactive Graphical SCADA System Data Collector dc.ex...
Design/Logic Flaw
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on user-supplied data from a constructed message received on the network. Affected Product: Interactive Graphical SCADA System Data Collector dc.exe...
CVE-2021-22824
The CVE-2021-22824 entry concerns the Schneider Electric Interactive Graphical SCADA System Data Collector (dc.exe) with affected versions up to 15.0.0.21320 and earlier. The root cause is a Buffer Copy without Checking Size of Input (CWE-120), due to missing length checks on user-supplied data i...
CVE-2021-22824
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on user-supplied data from a constructed message received on the network. Affected Product: Interactive Graphical SCADA System Data Collector dc.exe...
CVE-2021-22803
Schneider Electric IGSS DC module (dc.exe, v15.0.0.21243 and prior) is affected by CVE-2021-22803: Unrestricted Upload of File with Dangerous Type, enabling remote code execution by writing arbitrary files to folders in the DC module context via network messages. Root cause: lack of validation du...
CVE-2021-22802
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution due to missing length check on user supplied data, when a constructed message is received on the network. Affected Product: Interactive Graphical SCADA System Data Collector dc.ex...
CVE-2021-22803
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could lead to remote code execution through a number of paths, when an attacker, writes arbitrary files to folders in context of the DC module, by sending constructed messages on the network. Affected Product:...
Schneider Electric Interactive Graphical SCADA System 缓冲区错误漏洞
The Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. A buffer error vulnerability exists in the Schneider Electric Interactive Graphical SCADA...
Schneider Electric Interactive Graphical SCADA System访问控制错误漏洞
Schneider Electric Interactive Graphical SCADA System IGSS is a SCADA Data Acquisition and Supervisory System system for monitoring and controlling industrial processes from Schneider Electric, France. An access control error vulnerability exists in the Schneider Electric Interactive Graphical...