1419 matches found
CVE-2025-9038
Improper Privilege Management vulnerability in GE Vernova S1 Agile Configuration Software on Windows allows Privilege Escalation.This issue affects S1 Agile Configuration Software: 3.1 and previous version...
CVE-2025-9038
Improper Privilege Management vulnerability in GE Vernova S1 Agile Configuration Software on Windows allows Privilege Escalation.This issue affects S1 Agile Configuration Software: 3.1 and previous version...
CVE-2025-9038
CVE-2025-9038 affects GE Vernova S1 Agile Configuration Software on Windows (version 3.1 and earlier). The issue is described as improper privilege management that enables privilege escalation. The vulnerability targets the configuration software’s handling of privileges, with a local attack vect...
CVE-2025-9038 S1 Agile Privilege Escalation
Improper Privilege Management vulnerability in GE Vernova S1 Agile Configuration Software on Windows allows Privilege Escalation.This issue affects S1 Agile Configuration Software: 3.1 and previous version...
PT-2025-38727
Improper Privilege Management vulnerability in GE Vernova S1 Agile Configuration Software on Windows allows Privilege Escalation.This issue affects S1 Agile Configuration Software: 3.1 and previous version...
UBUNTU-CVE-2022-50317
In the Linux kernel, the following vulnerability has been resolved: drm/bridge: megachips: Fix a null pointer dereference bug When removing the module we will get the following warning: 31.911505 i2c-core: driver stdp2690-ge-b850v3-fw unregistered 31.912484 general protection fault, probably for...
The vulnerability of GE Vernova Intelligent Electronic Devices (IEDs) of the Universal Relay (UR) series, which stems from insufficient verification of data authenticity, allows intruders to circumvent existing security restrictions.
The vulnerability of GE Vernova Intelligent Electronic Devices IEDs from the UR series is related to insufficient verification of data authenticity. Exploiting this vulnerability can allow unauthorized actors to circumvent existing security restrictions remotely...
CVE-2024-27106
Vulnerable data in transit in GE HealthCare EchoPAC products...
CVE-2024-1629
Path traversal vulnerability in “deleteFiles” function of Common Service Desktop, a GE HealthCare ultrasound device component...
CVE-2024-27108
Non privileged access to critical file vulnerability in GE HealthCare EchoPAC products...
CVE-2022-43975
An issue was discovered in FC46-WebBridge on GE Grid Solutions MS3000 devices before 3.7.6.25p03.2.2.17p04.7p0. A vulnerability in the web server allows arbitrary files and configurations to be read via directory traversal over TCP port 8888...
CVE-2022-43976
An issue was discovered in FC46-WebBridge on GE Grid Solutions MS3000 devices before 3.7.6.25p03.2.2.17p04.7p0. Direct access to the API is possible on TCP port 8888 via programs located in the cgi-bin folder without any authentication...
CVE-2022-43977
An issue was discovered on GE Grid Solutions MS3000 devices before 3.7.6.25p03.2.2.17p04.7p0. The debug port accessible via TCP a qconn service lacks access control...
CVE-2021-29297
Buffer Overflow in Emerson GE Automation Proficy Machine Edition v8.0 allows an attacker to cause a denial of service and application crash via crafted traffic from a Man-in-the-Middle MITM attack to the component "FrameworX.exe" in the module "MSVCR100.dll"...
CVE-2021-27424
GE UR firmware versions prior to version 8.1x shares MODBUS memory map as part of the communications guide. GE was made aware a “Last-key pressed” MODBUS register can be used to gain unauthorized information...
CVE-2021-31477
This vulnerability allows remote attackers to execute arbitrary code on affected installations of GE Reason RPV311 14A03. Authentication is not required to exploit this vulnerability. The specific flaw exists within the firmware and filesystem of the device. The firmware and filesystem contain...
CVE-2021-27420
GE UR firmware versions prior to version 8.1x web server task does not properly handle receipt of unsupported HTTP verbs, resulting in the web server becoming temporarily unresponsive after receiving a series of unsupported HTTP requests. When unresponsive, the web server is inaccessible. By...
CVE-2020-25193
By having access to the hard-coded cryptographic key for GE Reason RT430, RT431 & RT434 GNSS clocks in firmware versions prior to version 08A06, attackers would be able to intercept and decrypt encrypted traffic through an HTTPS connection...
CVE-2020-16244
GE Digital APM Classic, Versions 4.4 and prior. Salt is not used for hash calculation of passwords, making it possible to decrypt passwords. This design flaw, along with the IDOR vulnerability, puts the entire platform at high risk because an authenticated user can retrieve all user account data...
CVE-2020-12017