16 matches found
EUVD-2018-10721
Malware in sbrugna...
EUVD-2019-5014
Malware in sbrugna...
EUVD-2019-5009
Malware in sbrugna...
CVE-2019-13559
GE Mark VIe Controller is shipped with pre-configured hard-coded credentials that may allow root-user access to the controller. A limited application of the affected product may ship without setup and configuration instructions immediately available to the end user. The bulk of controllers go int...
CVE-2019-13554
GE Mark VIe Controller has an unsecured Telnet protocol that may allow a user to create an authenticated session using generic default credentials. GE recommends that users disable the Telnet service...
CVE-2019-13554
GE Mark VIe Controller has an unsecured Telnet protocol that may allow a user to create an authenticated session using generic default credentials. GE recommends that users disable the Telnet service...
CVE-2019-13559
GE Mark VIe Controller is shipped with pre-configured hard-coded credentials that may allow root-user access to the controller. A limited application of the affected product may ship without setup and configuration instructions immediately available to the end user. The bulk of controllers go int...
Hardcoded credentials
GE Mark VIe Controller is shipped with pre-configured hard-coded credentials that may allow root-user access to the controller. A limited application of the affected product may ship without setup and configuration instructions immediately available to the end user. The bulk of controllers go int...
Design/Logic Flaw
GE Mark VIe Controller has an unsecured Telnet protocol that may allow a user to create an authenticated session using generic default credentials. GE recommends that users disable the Telnet service...
CVE-2019-13559
GE Mark VIe Controller is shipped with pre-configured hard-coded credentials that may allow root-user access to the controller. A limited application of the affected product may ship without setup and configuration instructions immediately available to the end user. The bulk of controllers go int...
CVE-2019-13554
GE Mark VIe Controller has an unsecured Telnet protocol that may allow a user to create an authenticated session using generic default credentials. GE recommends that users disable the Telnet service...
GE Mark VIe Controller CVE-2019-13554 Authorization Bypass Vulnerability
Description GE Mark VIe Controller is prone to an authorization-bypass vulnerability. Attackers can exploit this issue to gain unauthorized access to the affected system and obtain sensitive information. This may aid in further attacks. Technologies Affected Ge Mark VIe Controller Recommendations...
Siemens SINEMA Remote Connect Server ICSA-19-260-02 Multiple Security Vulnerabilities
Description Siemens SINEMA Remote Connect Server is prone to following security vulnerabilities: 1. Multiple security vulnerabilities 2. An information-disclosure vulnerability 3. A cross-site-request forgery vulnerability An attacker may leverage these issues to obtain potentially sensitive...
CVE-2018-19003
GE Mark VIe, EX2100e, EX2100eReg, and LS2100e Versions 03.03.28C to 05.02.04C, EX2100e All versions prior to v04.09.00C, EX2100eReg All versions prior to v04.09.00C, and LS2100e All versions prior to v04.09.00C The affected versions of the application have a path traversal vulnerability that fail...
Path traversal
GE Mark VIe, EX2100e, EX2100eReg, and LS2100e Versions 03.03.28C to 05.02.04C, EX2100e All versions prior to v04.09.00C, EX2100eReg All versions prior to v04.09.00C, and LS2100e All versions prior to v04.09.00C The affected versions of the application have a path traversal vulnerability that fail...
CVE-2018-19003
GE Mark VIe, EX2100e, EX2100eReg, and LS2100e Versions 03.03.28C to 05.02.04C, EX2100e All versions prior to v04.09.00C, EX2100eReg All versions prior to v04.09.00C, and LS2100e All versions prior to v04.09.00C The affected versions of the application have a path traversal vulnerability that fail...