Lucene search
K

7 matches found

EUVD
EUVD
added 2025/10/07 12:30 a.m.3 views

EUVD-2018-9666

Malware in sbrugna...

4.8CVSS5.1AI score0.00055EPSS
Exploits0References3
NVD
NVD
added 2018/10/10 5:29 p.m.11 views

CVE-2018-17925

Multiple instances of this vulnerability Unsafe ActiveX Control Marked Safe For Scripting have been identified in the third-party ActiveX object provided to GE iFIX versions 2.0 - 5.8 by Gigasoft. Only the independent use of the Gigasoft charting package outside the iFIX product may expose users ...

4.8CVSS5.2AI score0.00055EPSS
Exploits0References2
CVE
CVE
added 2018/10/10 5:0 p.m.56 views

CVE-2018-17925

CVE-2018-17925 concerns a vulnerability in the Gigasoft component of GE iFIX (ActiveX marked Safe For Scripting). Affected products include GE iFIX 2.0–5.0, 5.1, 5.5 and 5.8; older Gigasoft components may be used in other vendors’ products. The issue arises from an unsafe ActiveX control within t...

4.8CVSS5.2AI score0.00055EPSS
Exploits0References2Affected Software1
Cvelist
Cvelist
added 2018/10/10 5:0 p.m.10 views

CVE-2018-17925

Multiple instances of this vulnerability Unsafe ActiveX Control Marked Safe For Scripting have been identified in the third-party ActiveX object provided to GE iFIX versions 2.0 - 5.8 by Gigasoft. Only the independent use of the Gigasoft charting package outside the iFIX product may expose users ...

5.2AI score0.00055EPSS
Exploits0References2
CNVD
CNVD
added 2016/11/29 12:0 a.m.1 views

Remote Denial of Service Vulnerability in GE Configuration Software iFIX V5.8

GE Proficy HMI/SCADA-iFIX configuration software is used for process visualization, data acquisition, analysis, and monitoring of operations. The software utilizes a SCADA engine with multiple connectivity options and an open, highly scalable distributed network model. A remote denial of service...

6.8AI score
Exploits0
ICS
ICS
added 2013/07/27 6:0 a.m.22 views

Catapult Software DNP3 Driver Improper Input Validation

OVERVIEW This advisory was originally posted to the US-CERT secure Portal library on October 24, 2013, and is now being released to the NCCIC/ICS-CERT Web site. Adam Crain of Automatak and independent researcher Chris Sistrunk have identified an improper input validation in Catapult Software’s DN...

6.1AI score
Exploits0References10
Zero Day Initiative
Zero Day Initiative
added 2012/08/03 12:0 a.m.32 views

GE Proficy Historian ihDataArchiver.exe Multiple Opcode Parsing Remote Code Execution Vulnerabilities

This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of GE iFix. Authentication is not required to exploit this vulnerability. The specific flaw exists within the ihDataArchiver.exe process which listens by default on TCP port 14000. Several errors are...

10CVSS4.7AI score0.05549EPSS
Exploits0References1
Rows per page