EUVD
EUVD
•added 2025/10/03 8:07 p.m.•24 views

EUVD-2023-12636

Malicious code in bioql PyPI...

9.8CVSS9.2AI score0.00571EPSS
SaveExploits0References2
NVD
NVD
•added 2023/03/16 8:15 p.m.•44 views

CVE-2023-0598

GE Digital Proficy iFIX 2022, GE Digital Proficy iFIX v6.1, and GE Digital Proficy iFIX v6.5 are vulnerable to code injection, which may allow an attacker to insert malicious configuration files in the expected web server execution path and gain full control of the HMI software...

9.8CVSS9AI score0.00571EPSS
SaveExploits0References2
Prion
Prion
•added 2023/03/16 8:15 p.m.•38 views

Path traversal

GE Digital Proficy iFIX 2022, GE Digital Proficy iFIX v6.1, and GE Digital Proficy iFIX v6.5 are vulnerable to code injection, which may allow an attacker to insert malicious configuration files in the expected web server execution path and gain full control of the HMI software...

7.5CVSS9.5AI score0.00571EPSS
SaveExploits0References2Affected Software1
Cvelist
Cvelist
•added 2023/03/16 7:13 p.m.•58 views

CVE-2023-0598 GE Digital Proficy Code Injection

GE Digital Proficy iFIX 2022, GE Digital Proficy iFIX v6.1, and GE Digital Proficy iFIX v6.5 are vulnerable to code injection, which may allow an attacker to insert malicious configuration files in the expected web server execution path and gain full control of the HMI software...

7.8CVSS9.8AI score0.00571EPSS
SaveExploits0References2
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2023/03/16 12:00 a.m.•2 views

CVE-2023-0598: Improper Control of Generation of Code

GE Digital Proficy iFIX 2022, GE Digital Proficy iFIX v6.1, and GE Digital Proficy iFIX v6.5 are vulnerable to code injection, which may allow an attacker to insert malicious configuration files in the expected web server execution path and gain full control of the HMI software...

9.8CVSS6AI score0.00571EPSS
SaveExploits0References2
The Hacker News
The Hacker News
•added 2023/01/18 5:56 a.m.•12 views

CISA Warns of Flaws in Siemens, GE Digital, and Contec Industrial Control Systems

The U.S. Cybersecurity and Infrastructure Security Agency CISA has published four Industrial Control Systems ICS advisories, calling out several security flaws affecting products from Siemens, GE Digital, and Contec. The most critical of the issues have been identified in Siemens SINEC INS that...

10CVSS8.7AI score0.95404EPSS
SaveExploits5
Positive Technologies
Positive Technologies
•added 2016/07/15 12:00 a.m.•4 views

PT-2016-6679

Name of the Vulnerable Software and Affected Versions General Electric GE Digital Proficy HMI/SCADA - CIMPLICITY versions prior to 8.2 SIM 27 Description The issue is related to the mishandling of service DACLs, which allows local users to modify a service configuration. This can be achieved via...

6.3CVSS0.00394EPSS
SaveExploits0References5
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2016/07/15 12:00 a.m.•4 views

CVE-2016-5787: Exposure of Resource to Wrong Sphere

General Electric GE Digital Proficy HMI/SCADA - CIMPLICITY before 8.2 SIM 27 mishandles service DACLs, which allows local users to modify a service configuration via unspecified vectors...

6.3CVSS6.7AI score0.00394EPSS
SaveExploits0References2