Lucene search
+L

140 matches found

Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/04/17 12:00 a.m.•2 views

CVE-2024-3909: Stack-based Buffer Overflow

A vulnerability classified as critical was found in Tenda AC500 2.0.1.91307. Affected by this vulnerability is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be launched remotely. The...

9.8CVSS6.2AI score0.01676EPSS
SaveExploits0References3
CNNVD
CNNVD
•added 2024/04/17 12:00 a.m.•15 views

Tenda AC7 安全漏洞

Tenda AC7 is a 1200M dual-band wireless router designed for large households by Tenda Technology, which adopts the 802.11ac standard and supports dual-band concurrent transmission with a wireless rate of up to 1167Mbps. Tenda AC7 suffers from a command injection vulnerability that stems from the...

8.8CVSS8AI score0.01806EPSS
SaveExploits1References2
CVE
CVE
•added 2024/04/17 12:00 a.m.•89 views

CVE-2024-32281

The Tenda AC7V1.0 v15.03.06.44 firmware is vulnerable to a command injection flaw within the formexeCommand function. The root cause is the cmdinput parameter failing to properly filter special characters and commands. An attacker can exploit this lack of input validation to achieve arbitrary com...

8.8CVSS7.5AI score0.01806EPSS
SaveExploits1References1Affected Software1
CNVD
CNVD
•added 2024/03/29 12:00 a.m.•13 views

Tenda FH1205 formexeCommand method stack buffer overflow vulnerability

The Tenda FH1205 is a home wireless router from China's Tenda, geared toward the average home network environment, providing wireless connectivity. The Tenda FH1205 suffers from a stack buffer overflow vulnerability that originates from the cmdinput parameter of the formexeCommand method of the...

9CVSS8.4AI score0.01683EPSS
SaveExploits1References1
CNVD
CNVD
•added 2024/03/29 12:00 a.m.•9 views

Tenda FH1203 formexeCommand Method Buffer Overflow Vulnerability

Tenda FH1203 is a dual-band wireless router from Tenda China, mainly used for home network coverage. The Tenda FH1203 suffers from a buffer overflow vulnerability that originates from the cmdinput parameter of the formexeCommand method of the /goform/execCommand file that fails to correctly...

9CVSS8.3AI score0.01481EPSS
SaveExploits1References1
OSV
OSV
•added 2024/03/27 7:15 p.m.•13 views

CVE-2024-2990

A vulnerability, which was classified as critical, was found in Tenda FH1203 2.0.1.6. This affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The explo...

8.8CVSS6.3AI score0.01481EPSS
SaveExploits1References4
CVE
CVE
•added 2024/03/27 6:31 p.m.•83 views

CVE-2024-2990

CVE-2024-2990 affects Tenda FH1203 2.0.1.6 . The vulnerability is in the function formexeCommand of the file /goform/execCommand where manipulation of the argument cmdinput causes a stack-based buffer overflow . It can be exploited remotely, and the exploit has been disclosed publicly. The connec...

9CVSS8.9AI score0.01481EPSS
SaveExploits1References4Affected Software1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/27 12:00 a.m.•2 views

CVE-2024-2990: Stack-based Buffer Overflow

A vulnerability, which was classified as critical, was found in Tenda FH1203 2.0.1.6. This affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The explo...

9CVSS6.2AI score0.01481EPSS
SaveExploits1References3
Positive Technologies
Positive Technologies
•added 2024/03/27 12:00 a.m.•28 views

PT-2024-23044 · Tenda · Tenda Fh1202

Name of the Vulnerable Software and Affected Versions: Tenda FH1202 version 1.2.0.14408 Description: A critical issue has been found in the Tenda FH1202 router, affecting the formexeCommand function in the /goform/execCommand file. The manipulation of the cmdinput argument leads to a stack-based...

9CVSS8.8AI score0.01773EPSS
SaveExploits1References7
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/27 12:00 a.m.•2 views

CVE-2024-2980: Stack-based Buffer Overflow

A vulnerability, which was classified as critical, has been found in Tenda FH1202 1.2.0.14408. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The...

9CVSS6.3AI score0.01773EPSS
SaveExploits1References3
CNNVD
CNNVD
•added 2024/03/27 12:00 a.m.•11 views

Tenda FH1202 安全漏洞

The Tenda FH1202 is a wireless router from Tenda China. A buffer overflow vulnerability exists in the Tenda FH1202 formexeCommand method, which can be exploited by an attacker to execute arbitrary code on the system or cause a denial of service...

9CVSS8.2AI score0.01773EPSS
SaveExploits1References5
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/27 12:00 a.m.•3 views

CVE-2024-3008: Stack-based Buffer Overflow

A vulnerability, which was classified as critical, was found in Tenda FH1205 2.0.0.7775. Affected is the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. It is possible to launch the attack remotely. The explo...

9CVSS6.2AI score0.01683EPSS
SaveExploits1References3
BDU FSTEC
BDU FSTEC
•added 2024/03/22 12:00 a.m.•13 views

The vulnerability of the formexeCommand() function (/goform/execCommand) in the Tenda AC18 router’s microprogramming system allows a attacker to compromise the confidentiality, integrity, and accessibility of the protected information.

The vulnerability of the formexeCommand function /goform/execCommand in the Tenda AC18 router’s microprogramming system lies in the issue of the operation exceeding the buffer boundaries in memory when processing the cmdinput parameter. Exploiting this vulnerability allows an attacker to compromi...

9CVSS7.8AI score0.01278EPSS
SaveExploits0References3Affected Software1
CNVD
CNVD
•added 2024/03/22 12:00 a.m.•8 views

Tenda AC10U formexeCommand function buffer overflow vulnerability

Tenda AC10U is a dual-band Gigabit router with 802.11ac Wave 2.0 standard, supporting MU-MIMO technology with high through-wall capability and stable transmission characteristics. The Tenda AC10U suffers from a buffer overflow vulnerability, which originates from the cmdinput parameter of the...

9CVSS8.2AI score0.0148EPSS
SaveExploits1References1
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/20 12:00 a.m.•0 views

CVE-2024-2708: Stack-based Buffer Overflow

A vulnerability was found in Tenda AC10U 15.03.06.49 and classified as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has be...

9CVSS6.2AI score0.0148EPSS
SaveExploits1References3
CNVD
CNVD
•added 2024/03/19 12:00 a.m.•67 views

Tenda AC18 formexeCommand function buffer overflow vulnerability

The Tenda AC18 is a router from the Chinese company Tenda. Tenda AC18 V15.03.05.05 version of the buffer overflow vulnerability, the vulnerability stems from /goform/execCommand file formexeCommand function of the cmdinput parameter fails to correctly validate the length of the input data size, a...

9CVSS8.3AI score0.01278EPSS
SaveExploits0References1
OSV
OSV
•added 2024/03/17 9:15 a.m.•14 views

CVE-2024-2558

A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has...

8.8CVSS6.3AI score0.01278EPSS
SaveExploits0References3
Rapid7 Vulnerability Database (full)
Rapid7 Vulnerability Database (full)
•added 2024/03/17 12:00 a.m.•8 views

CVE-2024-2558: Stack-based Buffer Overflow

A vulnerability was found in Tenda AC18 15.03.05.05. It has been rated as critical. This issue affects the function formexeCommand of the file /goform/execCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has...

9CVSS6.3AI score0.01278EPSS
SaveExploits0References3
CNNVD
CNNVD
•added 2024/03/17 12:00 a.m.•16 views

Tenda AC18 Security Vulnerability

Tenda AC18 is a router from Tenda, China. A security vulnerability exists in Tenda AC18 version V15.03.05.05, which is caused by a stack-based buffer overflow in the cmdinput parameter of the formexeCommand function of the /goform/execCommand file...

9CVSS7.5AI score0.01278EPSS
SaveExploits0References4
BDU FSTEC
BDU FSTEC
•added 2024/01/18 12:00 a.m.•19 views

The vulnerability of the formexeCommand function in the wireless access point software Tenda W9 allows a intruder to execute arbitrary code.

The vulnerability of the formexeCommand function in the Tenda W9 wireless access point software exists due to the failure to implement measures to neutralize special elements. Exploiting this vulnerability allows a remote attacker to execute arbitrary code...

10CVSS8.2AI score0.01896EPSS
SaveExploits1References4
Rows per page
Query Builder