Lucene search
K

55 matches found

CVE
CVE
added 2026/01/15 8:28 p.m.8 views

CVE-2026-21920

CVE-2026-21920 affects Juniper Networks Junos OS on SRX Series. An unchecked return value in the DNS module causes the flowd process to crash and restart when processing specially crafted DNS requests, leading to DoS/service interruption. Affected versions include 23.4 before 23.4R2-S5, 24.2 befo...

8.7CVSS6.5AI score0.00021EPSS
Exploits0References2Affected Software1
EUVD
EUVD
added 2026/01/15 8:28 p.m.3 views

EUVD-2026-2685

An Unchecked Return Value vulnerability in the DNS module of Juniper Networks Junos OS on SRX Series allows an unauthenticated, network-based attacker to cause a Denial-of-Service DoS. If an SRX Series device configured for DNS processing, receives a specifically formatted DNS request flowd will...

8.7CVSS6.3AI score0.00021EPSS
Exploits0References3
Cvelist
Cvelist
added 2026/01/15 8:28 p.m.21 views

CVE-2026-21920 Junos OS: SRX Series: If a specific request is processed by the DNS subsystem flowd will crash

An Unchecked Return Value vulnerability in the DNS module of Juniper Networks Junos OS on SRX Series allows an unauthenticated, network-based attacker to cause a Denial-of-Service DoS. If an SRX Series device configured for DNS processing, receives a specifically formatted DNS request flowd will...

8.7CVSS0.00021EPSS
Exploits0References2
Vulnrichment
Vulnrichment
added 2026/01/15 8:28 p.m.3 views

CVE-2026-21920 Junos OS: SRX Series: If a specific request is processed by the DNS subsystem flowd will crash

An Unchecked Return Value vulnerability in the DNS module of Juniper Networks Junos OS on SRX Series allows an unauthenticated, network-based attacker to cause a Denial-of-Service DoS. If an SRX Series device configured for DNS processing, receives a specifically formatted DNS request flowd will...

8.7CVSS6.5AI score0.00021EPSS
Exploits0References2
CVE
CVE
added 2026/01/15 8:27 p.m.7 views

CVE-2026-21918

CVE-2026-21918 describes a Double Free vulnerability in the flow processing daemon (flowd) of Juniper Networks Junos OS on SRX and MX Series. The issue allows an unauthenticated, network-based attacker to cause a Denial-of-Service (DoS) by sending a specific sequence of TCP packets during session...

8.7CVSS6.5AI score0.00021EPSS
Exploits0References2Affected Software1
ATTACKERKB
ATTACKERKB
added 2026/01/15 8:27 p.m.2 views

CVE-2026-21918

A Double Free vulnerability in the flow processing daemon flowd of Juniper Networks Junos OS on SRX and MX Series allows an unauthenticated, network-based attacker to cause a Denial-of-Service DoS. On all SRX and MX Series platforms, when during TCP session establishment a specific sequence of...

8.7CVSS5.5AI score0.00021EPSS
Exploits0References3Affected Software1
EUVD
EUVD
added 2026/01/15 8:19 p.m.2 views

EUVD-2026-2687

A Loop with Unreachable Exit Condition 'Infinite Loop' vulnerability in the SIP application layer gateway ALG of Juniper Networks Junos OS on SRX Series and MX Series with MX-SPC3 or MS-MPC allows an unauthenticated network-based attacker sending specific SIP messages over TCP to crash the flow...

8.7CVSS6.5AI score0.00036EPSS
Exploits0References3
Vulnrichment
Vulnrichment
added 2025/10/09 3:40 p.m.3 views

CVE-2025-52960 Junos OS: SRX Series and MX Series: Receipt of specific SIP packets in a high utilization situation causes a flowd/mspmand crash

A Buffer Copy without Checking Size of Input vulnerability in the Session Initialization Protocol SIP ALG of Juniper Networks Junos OS on MX Series and SRX Series allows an unauthenticated, network-based attacker to cause a Denial of Service DoS. When memory utilization is high, and specific...

8.2CVSS6.2AI score0.00052EPSS
Exploits0References2
Cvelist
Cvelist
added 2025/10/09 3:40 p.m.7 views

CVE-2025-52960 Junos OS: SRX Series and MX Series: Receipt of specific SIP packets in a high utilization situation causes a flowd/mspmand crash

A Buffer Copy without Checking Size of Input vulnerability in the Session Initialization Protocol SIP ALG of Juniper Networks Junos OS on MX Series and SRX Series allows an unauthenticated, network-based attacker to cause a Denial of Service DoS. When memory utilization is high, and specific...

8.2CVSS0.00052EPSS
Exploits0References2
EUVD
EUVD
added 2025/10/07 12:30 a.m.1 views

EUVD-2017-2252

Malware in sbrugna...

8.6CVSS8.3AI score0.00772EPSS
Exploits0References3
EUVD
EUVD
added 2025/10/07 12:30 a.m.3 views

EUVD-2014-3763

Malware in sbrugna...

6.8CVSS6.4AI score0.00766EPSS
Exploits0References3
EUVD
EUVD
added 2025/10/07 12:30 a.m.1 views

EUVD-2014-3753

Malware in sbrugna...

7.8CVSS6.4AI score0.00693EPSS
Exploits0References4
EUVD
EUVD
added 2025/10/03 8:7 p.m.4 views

EUVD-2025-21149

Malicious code in bioql PyPI...

8.7CVSS6.6AI score0.00403EPSS
Exploits0References1
EUVD
EUVD
added 2025/10/03 8:7 p.m.3 views

EUVD-2022-27322

Malicious code in bioql PyPI...

7.5CVSS7.6AI score0.00302EPSS
Exploits0References1
Cvelist
Cvelist
added 2025/07/11 3:8 p.m.5 views

CVE-2025-52981 Junos OS: SRX Series: Sequence of specific PIM packets causes a flowd crash

An Improper Check for Unusual or Exceptional Conditions vulnerability in the flow processing daemon flowd of Juniper Networks Junos OS on SRX1600, SRX2300, SRX 4000 Series, and SRX5000 Series with SPC3 allows an unauthenticated, network-based attacker to cause a Denial-of-Service DoS. If a sequen...

8.7CVSS0.00403EPSS
Exploits0References1
OSV
OSV
added 2025/04/09 8:15 p.m.3 views

CVE-2025-30645

A NULL Pointer Dereference vulnerability in the flow daemon flowd of Juniper Networks Junos OS on SRX Series allows an attacker causing specific, valid control traffic to be sent out of a Dual-Stack DS Lite tunnel to crash the flowd process, resulting in a Denial of Service DoS. Continuous...

8.7CVSS5.8AI score
Exploits0References1
Vulnrichment
Vulnrichment
added 2025/04/09 7:52 p.m.7 views

CVE-2025-30645 Junos OS: SRX Series: Transmission of specific control traffic sent out of a DS-Lite tunnel results in flowd crash

A NULL Pointer Dereference vulnerability in the flow daemon flowd of Juniper Networks Junos OS on SRX Series allows an attacker causing specific, valid control traffic to be sent out of a Dual-Stack DS Lite tunnel to crash the flowd process, resulting in a Denial of Service DoS. Continuous...

8.7CVSS6.8AI score0.00397EPSS
Exploits0References1
Cvelist
Cvelist
added 2025/04/09 7:52 p.m.14 views

CVE-2025-30645 Junos OS: SRX Series: Transmission of specific control traffic sent out of a DS-Lite tunnel results in flowd crash

A NULL Pointer Dereference vulnerability in the flow daemon flowd of Juniper Networks Junos OS on SRX Series allows an attacker causing specific, valid control traffic to be sent out of a Dual-Stack DS Lite tunnel to crash the flowd process, resulting in a Denial of Service DoS. Continuous...

8.7CVSS0.00397EPSS
Exploits0References1
OSV
OSV
added 2024/10/11 4:15 p.m.3 views

CVE-2024-47504

An Improper Validation of Specified Type of Input vulnerability in the packet forwarding engine pfe Juniper Networks Junos OS on SRX5000 Series allows an unauthenticated, network based attacker to cause a Denial of Service Dos. When a non-clustered SRX5000 device receives a specifically malformed...

8.7CVSS5.8AI score0.00237EPSS
Exploits0References1
OSV
OSV
added 2024/10/11 4:15 p.m.1 views

CVE-2024-47503

An Improper Check for Unusual or Exceptional Conditions vulnerability in the flow processing daemon flowd of Juniper Networks Junos OS on SRX4600 and SRX5000 Series allows an unauthenticated and logically adjacent attacker to cause a Denial-of-Service DoS. If in a multicast scenario a sequence of...

7.1CVSS5.7AI score
Exploits0References1
Rows per page
Query Builder